GovChime
Notice ID: 6e43e1e9235d4cffa92636db70575440SolicitationArchived

Brand Name NOVO Ultimate System III

Archived on August 11, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
8:00 AM JST
Posted
July 14, 2026
Notice type
Solicitation
Set-aside
No Set aside used
NAICS
334517: Irradiation Apparatus Manufacturing
Agency
Department of WarDepartment of the Navy

Notice details

Office
USMC.MARCORP I&L.MARINE CORPS INSTALLATIONS COMMAND.MCIPAC.COMMANDING OFFICER
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
M6740026Q0045
Notice ID
6e43e1e9235d4cffa92636db70575440

Description

Please see the attached Solicitation No. M6740026Q0045 and the RFQ Cover Sheet for the detailed requirement.

Offerors shall submit their response to this RFQ no later than 27 July 2026 at 0800 (JST).

All questions shall be submitted via email to ho.h.lin.mil@usmc.mil and daniel.nachlas@usmc.mil no later than 20 July 2026 at 08:00 (JST).

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

SSgt Daniel Nachlas

Documents

Files (2)

  • RFQ Cover Sheet M6740026Q0045.pdf

    286 KBAdded in Solicitation version 3Posted
    Download
  • M6740026Q0045.pdf

    17 MBAdded in Solicitation version 3Posted
    Download

Lifecycle

  1. 3
    Version 3SolicitationArchivedCurrent

    Brand Name NOVO Ultimate System III

    Notice 6e43e1e9235d4cffa92636db70575440 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, “Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 effective date 3/13/2026. This solicitation is unrestricted. The associated North American Industrial Classification System (NAICS) code for this procurement is 334516, with a small business size standard of 1000 employees. The FSC/PSC is 6515. VA New Jersey Health Care System’s Research and Development Service located at 385 Tremont Avenue East Orange, NJ 07018-1023 is seeking to purchase SomnoFlo Electronic Vaporizer Systems Brand Name or Equal. Please see attached solicitation for additional details.
77%
Combined Synopsis09/18/2026
SOURCES SOUGHT NOTICE: The Department of Veterans Affairs, Network Contracting Office 4 (NCO 04), is conducting a market survey to identify potential sources to provide a Brand Name only Philips ST80i Stress Test System for the Wilmington VA Medical Center (WVAMC)- 1601 Kirkwood Hwy, Wilmington De 19805 . This notice is issued for informational planning purposes only and is not a request for quote or announcement of a solicitation. Submitting information for this notice is voluntary and VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice. No solicitation is available at this time. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. The purpose of this market research is to identify capable sources that are both experienced and qualified to supply a Philips ST80i Stress Test System in accordance with statement of work. The North American Industry Classification System Code (NAICS) is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing, and the small business size standard is 1,250 employees for this type of effort. Vendors must be registered in the System for Award Management (SAM) at https://www.sam.gov and shall complete electronic annual representations and certifications in SAM prior to award of contract. If you are responding as a Service-Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses (SDVOSB s and VOSB s), your company must be registered in VetCert and maintain a current certification (https://search.certifications.sba.gov/ ). CAPABILITY STATEMENT AND DOCUMENTATION: Companies are to provide a summary of your firm s capabilities, experience, and knowledge in providing these services. Sources are asked to provide the following information: 1. Company information: Company Name Company Address Company uei SAM Company NAICS Code(s) Point of Contact Name Point of Contact Phone Number Point of Contact Email Address Company Website (if available) 2. The North American Industry Classification System Code (NAICS) is 334510 Electronic and Precision Equipment Repair and Maintenance, and the small business size standard is 1,250 employees. Based on this information, please indicate whether your company is a: Service-Disabled Veteran Owned Small Business (SDVOSB) Veteran Owned Small Business (VOSB) 8(a) HUB Zone Small Business Women Owned Small Business Small Disadvantaged Business (SDB) Small Business Concern Large Business 3. Provide a summary of your firm s Ability/ Capability to meet the product described in this notice (see attached SOW). 4. Government contracts for these products in the last 3 years. Include: Government Agency Contract Number Dollar Value Period of Performance Government Point of Contact Information (name, email, phone number) Information regarding your company s capacity and capability to provide such products are to be submitted electronically on or before 5:00 PM, Wednesday, 11/11/2026 addressed to Christa Stine, Contract Specialist christa.stine@va.gov.
75%
Market Research11/11/2026
Sources Sought Notice Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC) Disclaimer: This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Information Requested from Industry: In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List. Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met. Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC) for Oklahoma City VA Medical Center (OKCVAMC). This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. Brand Name or Equal to QS3 qPCR System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics: Description Part Number Qty QS3 0.1 mL qPCR System with Laptop A28566 1 Fast 96 Well RNase P Verification Plate 4351979 1 Fast 96 Well Hardshell Clear Plate (20 pack) 4483485 1 Optical Adhesive Covers (25 per pack) 4360954 1 802.11ac/b/g/n Wi Fi Dongle A26774 1 Fast 96 Well ROI & Background Plates 4432426 1 PowerTrack SYBR Master Mix, 1 mL A46012 1 TaqMan Fast Advanced Master Mix, 1 mL 4444556 1 SmartStart qStudio 3 Orientation A28806 1 Salient Characteristics: System and Consumables QuantStudio 3 Real-Time PCR System Compatible with Applied Biosystems MicroAmp EnduraPlate optical 96-well fast clear reaction plates Supports barcoded, 0.1 mL reaction plates Includes or identifies the quantity of plates provided Identifies any additional consumables required for operation Thermal Control and Block Configuration 96-well sample block At least three independently controlled Peltier temperature zones Programmable temperature difference of up to 10°C across the block Maximum temperature difference of 5°C between adjacent zones Block temperature range of approximately 4°C to 99.9°C Reaction Volumes and Thermal Performance Supports reaction volumes of approximately 10 30 µL on a 0.1 mL block Supports reaction volumes of approximately 10 100 µL on a 0.2 mL block Maximum ramp rate of approximately 9.0°C per second for the 0.1 mL block Maximum ramp rate of approximately 6.5°C per second for the 0.2 mL block Optical Detection and Heated Cover Long-life white LED light source with a median operating life of at least 60,000 hours CMOS imaging system for data acquisition Data collection for each filter combination in less than two seconds Heated cover temperature range of approximately 50°C to 110°C Heated cover designed to minimize evaporation from reaction plates Storage, Connectivity, Power, and Reliability Compatible with the Connect platform Provides up to 1 TB of cloud-based storage Includes approximately 10 GB of onboard storage Stores approximately 1,000 5,000 standard absolute-quantification run files Compatible with 100 240 V electrical outlets without modification Provides run protection during network or power interruptions Includes information on data security, software requirements, warranty, technical support, maintenance, training, and recurring storage or software costs Brand Name or Equal to iBright FL1500 Imaging System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics: Description Part Number Qty iBright FL1500 Imaging System A44241 1 SmartStart iBright Orientation A34016 1 1 Preventive Maintenance visit for iBright FL1500 ZG61SCIB 1 Bolt Welcome Pack with iBlot 3 NW0412AI 1 iBright Protein Standard (25 µL) LC5605 1 iBright FL1500 2 Year Warranty 1 Salient Characteristics: Imaging Capabilities and Performance Chemiluminescent western blot imaging Protein gel, DNA gel, membrane, and stained SDS-PAGE gel imaging Automatic image capture, focus, exposure, and analysis Quantitative band analysis and background subtraction High sensitivity, broad dynamic range, and low-light detection Imaging of multiple samples, including up to four mini gels in one view Camera, Detection, Illumination, and Imaging Area Cooled scientific-grade CCD camera At least 16-bit image capture and approximately 9-megapixel resolution or higher Adjustable pixel binning and optical/digital zoom Imaging area of approximately 22.5 cm by 18 cm or larger Removable sample tray White-light and blue/green-light illumination Optional near-infrared illumination Chemiluminescent detection, multiple filter options, and long-life LED light sources Interface, Software, Storage, and Connectivity Integrated touchscreen and internal computer or workstation Automated focus, exposure, zoom, image enhancement, quantification, annotation, reporting, and analysis Molecular-weight analysis, where applicable TIFF, JPEG, PNG, PDF, and other common image formats At least 250 GB of internal storage USB and Ethernet connectivity Optional wireless or cloud connectivity Secure data transfer, user access controls, and software updates Accessories and Training Sample tray, imaging accessories, and white screen or equivalent for stained-gel imaging User manuals, quick-start guides, installation instructions, and training materials 3. Scope: The Oklahoma City VA Medical Center requires the Applied Biosystems QS3 qPCR System, iBright FL1500 Imaging System, and associated accessories to support research into osteoarthritis treatment and pain management. 4. Delivery: Department of Veterans Affairs Oklahoma City VA Medical Center 921 Northeast 13th Street Oklahoma City, OK 73104-5007 In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: NAICS Code: 334516 Company Name: Address: UEI (Unique Entity ID) Number: Contact Name: Phone No.: Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder: Yes No FSS/GSA Contract Number: Effective Date/ Expiration Date: Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Pricing Model Please Indicate Availability Below: (Yes / No / NA) All on FSS Open Market only Mix of FSS & Open Market Firm-Fixed Price Federal Acquisition Regulation (FAR) Market Rearch Questions: Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a: Domestic end product? _____________ (%) Foreign end product? _______________ (%) Country of Origin: Questions for Small Businesses ONLY: If subcontracting, what added value do you offer (RFO 52.215-23): Nonmanufacturer Rule (RFO 52.219-33): Does your company manufacturer these proposed items? [ ] yes [ ] no Does your company exceed 500 employees? [ ] yes [ ] no If yes, list # of employees: _________ Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [ ] yes [ ] no Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [ ] yes [ ] no Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [ ] yes [ ] no If yes, what is the manufacturer s name? ________________ Response Instructions: Do not provide more than 8 pages, including cover letter page. Submit your response via email to devin.reichert@va.gov Submit your response NLT 09:00 (MST) on October, 15th, 2026; Mark your response as Proprietary Information if the information is considered business sensitive. VA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516 (Analytical Laboratory Instrument Manufacturing) with a Small Business size of 1000 Employees. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List. (End of Document)
65%
Market Research10/15/2026
This is Public Notice. This is a brand name award notification for the contract awarded to Abbott Laboratories Inc. 3200 Lakeside DR Santa Clara, California 95054-2807. This contract is for EnSite X EP Mapping System & Peripherals.
63%
Sole Source / J&AOpen
This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with the format in Revolutionary FAR Overhaul (RFO) Part 12, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a separate solicitation will not be issued. The Iowa City VA Healthcare System has a requirement for a Thyroid Uptake System including delivery, installation and 1 year of service support with confirmation of equipment functioning properly before acceptance. 100% Set-Aside for SDVOSBs. See all attachments. All offers shall be emailed to: Joseph.Bennett@va.gov The Subject Line of all emails shall include: RFQ 36C26327Q0098 Offers shall be received by CO no later than: 05:00 PM CST November 13, 2026.
63%
Combined Synopsis11/13/2026

Additional Details

Solicitation Number

M6740026Q0045

Archive Date

Aug 11, 2026

Place of Performance Country

JAPAN

Office Address

FPO, AP, 96371-9001