Temporary Dehumidification System w/ Inline Heaters_Rev1
Archived on January 6, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 5:00 PM UTC−05:00
- Posted
- December 16, 2025
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- No Set aside used
- NAICS
- 532490: Other Commercial and Industrial Machinery and Equipment Rental and Leasing
- Agency
- Department of WarDepartment of the Navy
Notice details
- Office
- NAVSEA.NAVSEA SHIPYARD.PORTSMOUTH NAVAL SHIPYARD GF
- Place of performance
- Groton, Connecticut, 06340
- PSC
- 4120: AIR CONDITIONING EQUIPMENT
- Last updated
- Oct 28, 2026
Identifiers
- Solicitation number
- N3904026Q3088
- Notice ID
- 59f34e41a112490a9174dd51f757ea57
Description
See attachments for solicitation details.
REVISION 1: Adding the below Q&A, updating the Period of Performance, and extending the solicitation deadline to 12/22/25 @ 5:00 PMEST
- Will the desiccant be powered by a generator or an existing 200A utility service? Existing facility power
- Will the desiccant run 24/7 or specific hours of the day? Yes
- Can you please specify what will be powering the inline heaters and the footage of cord required to power them? Existing house power or generator? 10ft or greater whip with bare copper wire ends
- It looks like the heaters are going to be inline with the process ducting so we assume they will probably either 25', 50' or 75’ away from the DCCU. Assuming that the 200’ of ducting is split between the process and react from the DCCU. Yes
- Will the base provide their own duct clamps? No
- What is the application of the desiccant? Will the inline heaters be required if the desiccant output air is approx 140F? To strip moisture from the air. Inline heaters are required.
- On the day of delivery, will an allotted 8 hrs be sufficient for personnel entry, training, badging, inspections, set up, start up, commissioning, and training? yes
- Will the unit be in a secured area? Are electronic and wireless devices allowed in this area? Are gps locators on equipment acceptable? Yes secured area, use of wireless or electronic devices is per posted signage.
- Would you like the weekly inspection rates broke out if the unit does not require weekly inspections and maintenance? Please see the SOW for weekly inspection and maintenance requirements and include it in your pricing.
Award Overview
Contacts
Contracting Officer
Primary Contact
Documents
Select documents to download
Showing 5 of 5 items
Document | Source | Agency | Posted Date | File Size | Actions | |
|---|---|---|---|---|---|---|
| Combined Synopsis/Solicitation | DEPT OF THE NAVY | Dec 16, 2025 | 118.08 KB | |||
| Combined Synopsis/Solicitation | DEPT OF THE NAVY | Dec 16, 2025 | 662.8 KB | |||
| Combined Synopsis/Solicitation | DEPT OF THE NAVY | Dec 16, 2025 | 850.74 KB | |||
| Combined Synopsis/Solicitation | DEPT OF THE NAVY | Dec 16, 2025 | 863.85 KB | |||
| Combined Synopsis/Solicitation | DEPT OF THE NAVY | Dec 16, 2025 | 661.67 KB |
Lifecycle
Solicitation:
N3904026Q3088- Combined Synopsis
- 2×Combined SynopsisCurrentDec 9, 2025
Temporary Dehumidification System w/ Inline Heaters_Rev1
Similar Opportunities
Additional Details
Solicitation Number
N3904026Q3088
Archive Date
Jan 6, 2026
Office Address
PORTSMOUTH, NH, 03801-5000