[SCADA] MAINTENANCE FOR ELECTRICAL RECEIVING AND DISTRIBUTION SYSTEMS AND FACILITIES, AND SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM FOR THE U.S. NAVAL AIR FACILITY, ATSUGI AND THE U.S. FORCES JAPAN CONTROLLED AREAS IN KANTO PLAIN, JAPAN

Archived on August 22, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM UTC+09:00
Posted
August 23, 2023
Notice type
Solicitation
NAICS
221122: Electric Power Distribution
Agency
Department of WarDepartment of the Navy

Notice details

Office
NAVFACSYSCOM FAR EAST
Place of performance
AYASE-SHI, 252-1101
Last updated
Sep 25, 2026

Identifiers

Solicitation number
N4008423R8902
Notice ID
cfee218a3f61489b912b80d10731f513

Description

Amendment 0001 for Q and A, and extending the proposal submission due date. The Contractor shall furnish all labor, supervision, management, tools, materials, equipment, facilities, transportation, incidental engineering, and other items necessary to provide the services outlined below at U.S. Naval Air Facility Atsugi and the U.S. Forces Japan Controlled Areas in Kanto Plain, Japan under a performance-based contract that is comprised of both Recurring Work and Non-Recurring Work Items. The Contractor shall provide the following services: a. Maintenance, Inspection and Repair for Main Electrical Substation Facilities, 60 cycle power plant facility, building substations, and cubicle type secondary unit substations. b. Maintenance, Inspection and Repair for various substation facilities. c. Maintenance, Inspection and Repair for various high voltage and low voltage equipment d. Maintenance and Repair of Supervisory Control and Data Acquisition (SCADA) systems.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Secondary Contact

Documents

No documents available.

Lifecycle

Solicitation:N4008423R8902
  1. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. 5×
    SolicitationCurrentJul 21, 2023

    [SCADA] MAINTENANCE FOR ELECTRICAL RECEIVING AND DISTRIBUTION SYSTEMS AND FACILITIES, AND SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM FOR THE U.S. NAVAL AIR FACILITY, ATSUGI AND THE U.S. FORCES JAPAN CONTROLLED AREAS IN KANTO PLAIN, JAPAN

    Notice cfee218a3f61489b912b80d10731f513 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
The Naval Facilities Engineering Systems Command (NAVFAC) intends to award a Utility Energy Service Contract (UESC) to Baltimore Gas and Electric Company (BGE) for the design, construction, commissioning, and financing of a comprehensive energy resilience project at Naval Support Activity (NSA) Annapolis, Maryland. The proposed project, estimated at approximately $45 million, will include a Combined Heat and Power (CHP) cogeneration plant integrated with a microgrid to enhance installation energy resilience. Major project elements include: A CHP system supporting an estimated 19 MW peak electrical demand, including three natural gas-fired turbines and associated heat-recovery systems; An integrated microgrid control system capable of island-mode operation during utility grid outages; An absorption chiller at the Lejeune Chilled Water Plant (597U) utilizing recovered waste heat; Relocation and upgrade of the 13C-1 electrical substation; Required natural-gas infrastructure upgrades and electric-grid interconnection activities; An Investment Grade Audit (IGA), design, engineering, construction, testing, commissioning, and construction management; and Operator training and project turnover documentation. Basis for Intended Sole Source The Government intends to use other than full and open competition pursuant to 10 U.S.C. § 3204(a)(1) and FAR 6.302-1, Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. The proposed action will be implemented as a UESC pursuant to 10 U.S.C. § 2913(d). BGE is the franchised electric and natural-gas utility serving NSA Annapolis and owns and operates the affected utility distribution infrastructure. GSA Areawide Public Utility Contract No. 47PA0724D0003 provides for BGE electric, natural-gas, and energy-management services within its franchised service territory. The contemplated UESC requires integrated responsibility for natural-gas capacity upgrades, electric-system interconnection, grid coordination, and modifications affecting BGE-owned or controlled infrastructure. These functions are integral to the CHP, microgrid, and island-mode requirements. The Government issued a Sources Sought Notice on February 5, 2026, which closed on February 20, 2026. Five firms responded to the notice. Based on the Government’s market research, acquisition planning, and review of the responses received, Baltimore Gas and Electric Company (BGE) was determined to be the only responsible source capable of satisfying the Government’s requirements. BGE was the only respondent possessing the requisite utility-service authority, control of the affected infrastructure, and ability to execute or authorize the necessary utility-system modifications and interconnection activities required to perform the contemplated UESC. Submission of Capability Information This notice is not a request for competitive proposals. However, responsible sources that believe they possess the capability, legal authority, and financing capacity to perform the complete requirement may submit a written capability statement. Capability statements should demonstrate: Legal authorization to provide the required electric and natural-gas utility services to NSA Annapolis; Authority and ability to execute or authorize the required utility-infrastructure modifications; Ability to perform and coordinate required electric-grid interconnection activities, including coordination with PJM Interconnection and applicable stakeholders; Experience with projects of comparable size, scope, and complexity under a UESC or comparable utility-financed arrangement; and Ability to provide the financing necessary to implement the project. Responses shall contain sufficient information for the Government to determine whether the respondent can satisfy the complete requirement and shall be submitted electronically in PDF format to olisha.g.costa.civ@us.navy.mil no later than 1:00 PM Eastern Time on Tuesday, November 10, 2026. The Government will consider timely responses before determining whether to proceed with the contemplated sole-source action. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The Government will not pay for information submitted in response to this notice.
-Pre-Solicitation11/10/2026
Amendment 0001 The outcomes to be achieved are for the contractor to provide all management, supervision, quality control, labor, tools, equipment, material, supplies, incidental engineering, and transportation necessary to provide Maintenance for Electrical Receiving and Distribution Systems and Facilities, Supervisory Control and Data Acquisition (SCADA) System at the U.S. Naval Air Facility Atsugi, Japan as outlined in the Performance Work Statement.
-Solicitation09/04/2026
THIS NOTICE DOES NOT CONSTITUTE A REQUEST FOR EITHER A QUOTE OR PROPOSAL OR AN INVITATION FOR A BID. THE INTENT OF THIS SOURCES SOUGHT IS TO IDENTIFY POTENTIAL OFFERORS TO RECAPITALIZE THE NAVY HIGH VOLTAGE 230KV TRANSMISSION LOOP AND ALL ANCILLARY EQUIPMENT AND GEAR AT NAVAL SUBMARINE BASE KINGS BAY, GEORGIA. THE WORK MUST COMPLY WITH ALL APPLICABLE NAVAL AND UTILITY PROVIDER PHYSICAL AND CYBERSECURITY REQUIREMENTS. IT REQUIRES SEAMLESS COORDINATION AND A SINGLE POINT OF ACCOUNTABILITY FOR EXECUTION WITHOUT UNNECESSARY SERVICE DISRUPTIONS OR DELAYS. NO SOLICITATION OR SPECIFICATIONS OR DRAWINGS ARE CURRENTLY AVAILABLE. The purpose of this notice is to gain knowledge of qualified and interested participants in any of the following categories. These include large business, small business, 8(a) business development participants, HUBZone small business concerns, service-disabled veteran-owned small business concerns, veteran-owned small business concerns, and women-owned small business concerns. Potential sources should have current relevant qualifications, experience, security-cleared personnel, security approvals, equipment, financial capability, and cybersecurity certifications relative to the project. The project entails utility infrastructure upgrades and connection facilities for the Navy-owned and operated 230kV electrical power transmission loop that services NSB Kings Bay, Georgia. The recapitalized infrastructure must be capable of safely and reliably interconnecting with the regional 230kV transmission grid. Prior experience in coordinating high-voltage interconnections with a regulated utility provider is an essential requirement. Capabilities including live-line interconnection work, secure supply chain management, and cybersecurity expertise (e.g., NERC CIP, DoD UFC 4-010-06 for Industrial Control Systems) are considered essential for the timely and cost-effective completion of the project without coordination delays or interoperability concerns. The Government contemplates an acquisition to accomplish the wholesale recapitalization and cybersecurity hardening of the Navy-owned high-voltage transmission line and associated gear at NSB Kings Bay, Georgia. The modernized on-base grid will remain solely under the operational control of the U.S. Navy and is intended to service only the installation. The system must be designed to safely coordinate with the regional transmission utility for grid stability and reliability at the point of interconnection. Work will include relocation of the high power loop and crossing tower across the North River to a geotechnically stable site. It includes replacement of conductors along the primary transmission corridor. The new installation must meet all required Department of Defense and industry cybersecurity standards. This includes the wholesale modernization of substation digital protective relays with utility-grade devices and the implementation of a secure, encrypted Supervisory Control and Data Acquisition (SCADA) system. The Government’s SCADA system must be capable of providing necessary operational coordination and data exchange with the utility provider’s dispatch center via a secure communications gateway. The contractor will replace closed circuit television metering transformers with fault monitoring capability. The work requires replacement of porcelain insulators, high-voltage bushings, surge arrestors, and ground-grid bonding systems ensuring compatibility with incoming power feed loads and feeds. The contractor must remove manual or gang-operated air disconnect switches at the entry bays of Substations 1 through 3. The project includes installation of smart supervisory-controlled Motor-Operated Disconnects and vacuum or SF6 circuit breakers equipped with high-speed differential bus and transformer protection schemes. It also requires wholesale modernization of substation digital protective relays utility-grade devices with full coordination between the encrypted installation Supervisory Control and Data Acquisition (SCADA) telemetry. All telemetry and relay configurations must comply with North American Electric Reliability Corporation (NERC) Critical Infrastructure Protection (EIP) standards. They must also comply with applicable DoD Unified Facilities Criteria 4-010-06 for Industrial Control Systems (ICS) standards and ad-hoc compatibility with existing utility infrastructure as determined by the agency. The anticipated period of performance is approximately 900 calendar days from award. The estimated magnitude for this procurement is between $100,000,000 to $250,000,000. The North American Industry Classification System Code (NAICS) is 221122 for Electric Power Distribution with a small business size standard of 1,100 employees. In accordance with Federal Acquisition Regulation (FAR) 15.101(c)(2), responses to this notice are not offers and the Government will not accept them to form a binding contract. Any information submitted by respondents to this notice is strictly voluntary. The Government will use the sources sought responses along with other market research to make various determinations regarding the procurement of the subject requirement. Industry will be notified of the results of the market research via the pre-solicitation or synopsis notice as applicable. GPC owns and operates the regional 230kV transmission grid that provides bulk power to the NSB Kings Bay point of interconnection. Any contractor performing this work must deliver a system that meets all relevant industry standards for protection, control, and communications (e.g., NERC, IEEE) to ensure safe and reliable grid operations. The design must allow for the necessary exchange of telemetry and operational data with GPC to ensure grid stability, without requiring the use of any proprietary utility software, hardware, or protocols on the government-owned portion of the system. Interested and responsible parties experienced in wholesale high-voltage power line work in Tier 3 security military installations with all necessary credentials and accreditations for both applicable naval and regional integration and interoperability standards should identify their interest and capability to respond to the requirement. We place special emphasis on cybersecurity specifications and supply chain security. Interested and responsible parties should use the attached questionnaire to respond to this notice. Responses to this notice must be submitted in electronic Adobe PDF format and attached to an email addressed to ryan.d.bell16.civ@us.navy.mil and rebecca.m.jones75.civ@us.navy.mil. Please identify “Recapitalize 230kV Transmission Loop at NSB Kings Bay” in the subject line of your response. Responses are limited to 5 pages in length and 5MB in size. You should only include the information requested in the attached questionnaire. Do not submit brochures or other corporate marketing information. The due date for responses is 1400 hours EDT on 13 November 2026. Responses received by the due date and time of this notice will be considered by the Government. Any questions submitted via email to the recipients identified above prior to the due date for responses will be considered. No additional questions will be addressed. Interested parties are responsible for verifying receipt of communications. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS ANNOUNCEMENT OR ANY FOLLOW-UP INFORMATION REQUESTS. IN ORDER TO PROTECT THE PROCUREMENT INTEGRITY OF ANY FUTURE PROCUREMENT ARISING FROM THIS ANNOUNCEMENT, INFORMATION REGARDING THE TECHNICAL POINT OF CONTACT WILL NOT BE GIVEN AND NO APPOINTMENTS FOR PRESENTATIONS WILL BE MADE.
-Market Research11/13/2026
NAVFACSYSCOM NW intends to issue a Limited-Source Utility Service Master Basic Ordering Agreement (BOA) to utility service providers that have agreements to provide utility services within the Northwest?s Area of Responsibility (NW AOR), with most services performed in Washington State under NAICS Codes 221122 Electric Power Distribution and 221210 Natural Gas Distribution. Only current providers with utility service agreements with NAVFACSYSCOM NW will be considered. The capacity of the Master BOA may not exceed $99,000,000 dollars with a five-year period of performance. Multiple BOAs will be awarded off the Master BOA to authorized utility service providers for energy management services, including energy and water efficiency improvements and energy demand reduction under 42 U.S.C. ? 8256. Services will emphasize energy demand or conservation including improving operation and maintenance, preliminary assessments, field investigations, Investment Grade Audit Reports, installing materials, devices, instruments, or equipment, or eliminating energy load to reduce the amount of energy needed in a facility. Additional utility services include emergency utility work in support of maintenance, repairs or outages, and utility construction services under10 U.S.C. ? 2913(d). Utility providers shall furnish all material, supervision, tools, equipment, labor, transportation, subcontract management, project management and, upon mutual agreement, initial capital to implement such projects as specified in individual Task Orders. No funding will be obligated as part of this synopsis or on the Master BOA. This solicitation will be open for five years or until the agreement capacity is met. All questions related to this Synopsis should be directed to: Eleanor Drake at Eleanor.drake.civ@us.navy.mil.
-Combined Synopsis05/30/2025
QUESTIONS REGARDING THIS RFI ARE DUE TO SIDNIA.FINKE@NAVY.MIL BY 1600 LOCAL TIME ON 1 OCTOBER 2018. The Government intends to provide responses to all questions by 5 October 2018 as an attachment to this RFI.
-Market ResearchOpen

Additional Details

Solicitation Number

N4008423R8902

Archive Date

Aug 22, 2024

Place of Performance Country

JPN

Office Address

FPO, AP, 96349-0013