Notice ID: b86ba6e138614ba2a6e0bfdbe6b1012dSolicitation
Results - Demolish Bulk Fuel Facility Cutler
Archived on August 3, 2024. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 11:00 AM UTC−04:00
- Posted
- July 19, 2024
- Notice type
- Solicitation
- Set-aside
- Small Business Set Aside - Total
- NAICS
- 237120: Oil and Gas Pipeline and Related Structures Construction
- Agency
- Department of WarDepartment of the Navy
Notice details
- Office
- NAVFACSYSCOM MID-ATLANTIC
- Place of performance
- Cutler, ME, 04626
- Last updated
- Sep 25, 2026
Identifiers
- Solicitation number
- N4008524B2507
- Notice ID
- b86ba6e138614ba2a6e0bfdbe6b1012d
Description
The work includes all labor, material, equipment, transportation, supervision, and incidental related work to demolish three existing bulk tanks and associated piping in the bulk tank area at NSA Cutler in Cutler, Maine. It also includes the demo of the four transient fuel tanks and their corresponding dog houses covering the utility pits. A total of four new 50,000 gal tanks will be installed in the existing bulk tank area and four 20,000 gal tanks will be installed in the transient fuel area. There are 11 bid options. Bid option 1: Includes the demo of the bulk tank berm oil water separator. Bid option 2: Includes providing a 6 inch concrete slab on abandoned bulk tank foundation. Bid option 3: Includes the demo of cantilevered concrete pan at transient tank dog house. Bid option 4: Includes providing a reinforced membrane waterproofing system to building. Bid option 5: Includes providing concrete repairs inside transient utility tunnel - Crack Injection. Bid option 6: Includes providing concrete repairs inside transient utility tunnel - Type B Spall. Bid option 7: Includes painting the bulk fuel tank support pipes. Bid option 8: Includes mill and overlay of roadways around project area. Bid option 9: Includes Fuel oil delivery and tank filling upon completion of Phase 2. Bid option 10: Includes on site temporary fuel storage for fuel oil removed as part of Phase 2. Bid option 11: provides for the installation of bollards for transient tank parking lot.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Matthew Thomsen
Secondary Contact
Jonathan Erickson
Documents
No documents available.
Lifecycle
Solicitation:
N4008524B2507- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- Pre-SolicitationMay 23, 2024
Demolish Bulk Fuel Facility Cutler
- 4×SolicitationCurrentJun 12, 2024
Results - Demolish Bulk Fuel Facility Cutler
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
ID-CAMAS NWR- Fuel Tanks Wiring | 66% | Solicitation | 10/08/2026 |
59% | Awarded | Open | |
Description This is a solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 75110PR270000104 is issued as a request for quotation (RFQ) for gas-leak detection and repair, gas-valve installation, gravel backfill, asphalt patching, and site cleanup at Birmingham Southern College in Birmingham, Alabama. This acquisition is set aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01 Effective Date 03/13/2026. The associated North American Industrial Classification System (NAICS) code for this procurement is 237120, with a small business size standard of $45.0M. Product Service Code is Z2NA. Submission of offers. Submit signed and dated offers to the office specified in this solicitation at or before the exact time specified in this solicitation. As a minimum, offers shall include— (1) The solicitation number. (2) The name, address, telephone number of the Offeror. (3) The Offeror’s Unique Entity Identifier (UEI) (4) Information necessary to evaluate the factors contained in the provision at 52.212-2 (5) Responses to provisions that require Offeror completion of information, representations, and certifications (other than those collected via the System for Award Management (SAM)); and (6) A statement specifying the extent of agreement with all terms, conditions, and provisions included in the solicitation and any solicitation amendments. Period for acceptance of offers. The Offeror agrees to hold the prices in its offer firm for 30 calendar days from the date specified for receipt of offers, unless another time period is specified in an addendum to the solicitation. The Coast Guard Training Center Birmingham Southern is seeking to purchase gas-leak repair services, including excavation, gas-line repair, gas-valve installation, testing, gravel backfill, asphalt patching, and site cleanup. All interested companies must provide quotation(s) for the following services: CLIN 0001 — Gas Leak Detection, Excavation, Spoil Removal, and Gravel Backfill. The Contractor shall locate the gas leak, saw-cut and excavate the parking lot as needed, use required safety measures, remove and dispose of excavated material and debris, and place and compact clean gravel or approved backfill after repair and testing. The expected excavation area is about 6 feet by 6 feet and up to 6 feet deep. The Government will provide utility markings before excavation; however, the Contractor remains responsible for safe digging. This CLIN is associated with SOW Task 2.1, SOW Task 2.3, and SOW Section 5.0. CLIN 0002 — Gas-Line Repair, Valve Installation, Testing, and Test Record. The Contractor shall provide all labor, materials, equipment, pipe, fittings, connectors, one new gas shutoff valve, and testing needed to repair the identified gas leak. The Contractor shall test the repaired gas line and valve before backfill and provide a written test record to the GTR and Contracting Officer. The Contractor shall not restart gas service until testing is successful and any required gas-utility approval is received. This CLIN is associated with SOW Task 2.2. CLIN 0003 — Asphalt Repair. After the gas-line repair, testing, and backfill are complete, the Contractor shall prepare the base and install an asphalt patch. The patch shall match the existing pavement as closely as practical, be properly compacted and level with the surrounding surface, and be safe for normal parking-lot traffic. The Contractor shall seal edges and joints as needed. This CLIN is associated with SOW Task 2.3. CLIN 0004 — Site Cleanup and Demobilization. The Contractor shall remove all debris, spoils, excess materials, equipment, signs, barriers, and temporary items from the work area. The Contractor shall leave the site clean, orderly, and safe for normal use. This CLIN is associated with SOW Task 2.4. Reference Attached Statement of Work in Solicitation 75110PR270000104 The period of performance for this firm-fixed-price contract must not exceed ten (10) business days from the date of award. All work, including final cleanup and demobilization, must be completed within this period Place of Performance The primary place of performance is the parking lot at Coast Guard Training Center Birmingham Southern, 900 Arkadelphia Road, Birmingham, AL 35204. 52.237-1 Site Visti (Apr 1984) To facilitate this process, an organized site visit has been scheduled for November 5, 2026, at 10:00am cst. Participants are requested to assemble at Training Center Birmingham main gate. Please note that all visitors must provide the following information prior to scheduling a site visit: full legal name, date of birth, contact number, email address, Real Id Driver’s License, registration of vehicle and proof of insurance. No personnel with felony convictions are permitted to access Coast Guard facilities under any circumstance. All vendors interested in attending a site visit shall submit their request and information by sending an email to john.h.caicedo2@uscg.mil with the following information: 1: Company Name 2. Company Phone 3: Visitor Name 4: Last 4 of SSN: 5: Date of Birth: 6: Place of Birth: 7: Real Id Driver’s License Number: | 59% | Solicitation | 11/12/2026 |
On or about 20 May 2026, Government intends to issue a solicitation for ?Grand Forks Fueling System Repair.? The solicitation will close on or about 15 June 2026. This solicitation will be 100% set-aside for Small Business. | 59% | Pre-Solicitation | Open |
14 July 2026: The purpose of Amendment 0001 is to extend the proposal due date, update documents, and incorporate missing documents into the solicitation.________________THE DOCUMENT NAMED: 26-R-A056-SPECS HAS BEEN UPDATED; PLEASE ENSURE YOU ARE USING THE CORRECT VERSION DATED APRIL 2026. The previous version dated October 2025 is not valid and has been removed. This project includes performing repairs to two aboveground horizontal bulk storage tanks and their associated equipment. These repairs include providing grounding systems, pipe supports, replacement nozzles, replacement normal vents, independent level alarms, mechanical clock-type level gauges, and automatic tank gauging systems. | 59% | Solicitation | 07/28/2026 |
Additional Details
Solicitation Number
N4008524B2507
Archive Date
Aug 3, 2024
Office Address
NORFOLK, VA, 23511-0395