GovChime
Notice ID: 3c866cb89a40488d8eded48762d27797Solicitation

Sensing Technology with Software

Archived on September 21, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM UTC−04:00
Posted
September 19, 2024
Notice type
Solicitation
Agency
Department of WarDepartment of the Navy

Notice details

Office
NORFOLK NAVAL SHIPYARD GF
Place of performance
Portsmouth, VA, 23709
Last updated
Dec 4, 2025

Identifiers

Solicitation number
N4215824QE081
Notice ID
3c866cb89a40488d8eded48762d27797

Description

Please read the complete descriptions of all 4 CLINS/ITEMS. You must check off, intiial and complete the attachment labeled "Attachment 1-Technical Capapbility Statement". Please check yes or no to each item as applicable. On your quote on the RFQ document (N4215824QE081) please provide all costs to include shipping/freight. Those cannot be added later. The lowest price that is technically acceptable by our engineering team will win the award.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:N4215824QE081
  1. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. SolicitationCurrentSep 19, 2024

    Sensing Technology with Software

    Notice 3c866cb89a40488d8eded48762d27797 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
LiSA (Lithium Sensing with Advanced Polymer Systems) is a field-deployable, polymer-based sensing platform from Los Alamos National Laboratory that enables rapid, in situ detection of lithium in geothermal brines and clay-rich formations — eliminating the need for costly full-depth drilling and time-intensive laboratory assays during early-stage exploration. Engineered to operate under variable temperature, salinity and pH conditions typical of lithium-hosting environments, LiSA allows exploration teams to confirm lithium presence in real time, reduce exploration risk and accelerate resource validation. By lowering costs, shortening decision cycles and improving targeting accuracy, the technology addresses a critical bottleneck in domestic lithium development and offers scalable potential for adaptation to other critical minerals, positioning licensees at the forefront of next-generation resource exploration. Technology Description: LiSA works by using a specially designed sensing material that selectively recognizes lithium when it comes into contact with underground fluids or soil. The sensing material is integrated into a portable platform that can be deployed directly in the field, where it interacts with samples onsite and produces a measurable signal if lithium is present. Because the sensing component is engineered to remain stable under the high salinity, temperature and varying chemical conditions typical of lithium-bearing environments, it can function reliably outside of a laboratory setting. In essence, the system translates the chemical presence of lithium into a rapid, field-readable response that helps guide exploration decisions in real time. The Opportunity: By integrating LiSA’s selective sensing technology into exploration services, downhole tools, surface sampling systems, geothermal operations or direct lithium extraction (DLE) platforms, our partners can offer their customers faster resource validation, reduced exploration risk and improved decision-making in the field. LiSA provides a pathway to differentiate your portfolio with real-time, on-site lithium detection capability while positioning your organization at the forefront of domestic critical mineral development, with potential expansion into sensing for other high-value elements as market demand evolves. Key Advantages: Field-deployable and portable – Enables onsite lithium detection rather than requiring laboratory analysis. In situ measurement – Identifies lithium directly in subsurface fluids and soils without full core recovery. Faster decision-making – Provides near real-time results to guide drilling and exploration strategy. Lower exploration costs – Reduces reliance on expensive drilling campaigns and lab assays. Operates in harsh environments – Engineered to function under variable temperature, salinity, and pH typical of geothermal and clay systems. Platform adaptability – Tunable polymer approach offers potential extension to other critical minerals. Market Applications: Lithium mining and mineral exploration Geothermal energy development Direct lithium extraction and brine processing Oil and gas field services and subsurface technologies Analytical instrumentation and field sensing technologies Development Status: TRL 4 US Patent pending LA-UR-26-23292 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
71%
Special Notice12/07/2026
This invention by scientists at Los Alamos National Laboratory (LANL) introduces a new type of real-time hydrogen fuel contamination detector that can sense tiny amounts of harmful contaminants before they reach a fuel-cell vehicle. It works by using a special membrane that keeps itself properly hydrated using an internal water reservoir, allowing it to stay sensitive even when measuring completely dry hydrogen—a major challenge for existing sensors. Even small amounts of impurities can permanently damage a fuel-cell car’s power system, and today’s testing methods are slow, expensive, and often done only after problems occur. By enabling continuous, in-line monitoring at hydrogen fueling stations, this technology helps ensure that hydrogen is clean and safe, supporting the growth of a reliable and consumer-friendly hydrogen economy. The Challenge: As hydrogen becomes a mainstream clean fuel, even tiny impurities—like CO, H₂S, or excess moisture—can permanently damage the sensitive fuel-cell systems that power vehicles and equipment. Yet today, hydrogen quality is typically verified using expensive, lab-based instruments that require expert operators and provide results only after the fact. This delay means a single contaminated batch can affect many vehicles before anyone realizes there’s a problem. Traditional sensor concepts have failed because they require adding moisture to the hydrogen stream, which interferes with detecting water contamination and violates emerging fuel standards. The industry needs a simple, real-time, in-line quality monitor that works with dry hydrogen and can be deployed directly at fueling stations. The Solution: The electrochemical Hydrogen Contamination Detector (HCD) is a low-cost device based on the very same materials and components that make up PEM fuel cells. It uses an ultra-low Pt-loaded sense electrode that is similar to a fuel cell electrode but hypersensitized to impurities by virtue of the greatly reduced catalyst loading. Impurities that bind to Pt catalysts inside the fuel cell and interfere with hydrogen absorption and dissociation will behave the same way to the low Pt-loaded HCD working electrode. The low loading makes the HCD even more susceptible to the effects of trace levels of high-impact impurities. The HCD can work in completely dry hydrogen because of LANL’s patented internal water reservoir and wicking mechanism. It can function at much higher sampling pressures than commercial analyzers because it is constructed with off-the-shelf single cell hardware that can easily handle pressures up to 250psi. The HCD approach applies a voltage to electrochemically pump hydrogen gas through the HCD while sampling the dry hydrogen stream to be analyzed for fuel quality. If contaminants are present, the measured hydrogen pumping current will decrease. At well-defined intervals, a high voltage pulse is applied to electrochemically “clean” the ultra-low loaded Pt electrode that “resets” the HCD continuously. The HCD not only detects the impurity but also can track the impurity level in the sample gas as it rises and falls over time. By comparing the response to a certified ultra-high purity “zero-gas” hydrogen source and prior calibration with span gases, the station operator will be immediately informed if the hydrogen to be sold is contaminated and at near real time. In the many baseline experiments performed over 18 months of testing, the HCD has a stable average baseline current demonstrating the efficacy of the approach. Key Advantages: True real-time monitoring: Detects contamination instantly for the 3 most severe fuel cell stack contaminants and does so before it reaches vehicles or equipment. Works with dry hydrogen: Eliminates the need to humidify the gas stream, enabling accurate measurement of all impurities—including water. Compatible with fueling infrastructure: Uses proven PEM fuel-cell components and can be installed directly in high-pressure hydrogen delivery lines. Protects fuel-cell investments: Prevents costly damage to fuel-cell stacks by catching impurities early. Enables the hydrogen economy: Provides the reliability and safety assurance required for widespread adoption of hydrogen vehicles and refueling stations. Market Applications: Hydrogen Production & Distribution Future concepts for Geological Storage of Hydrogen and Co-mingling of Fuels (e.g., hydrogen and methane/natural gas) Fueling Infrastructure Fuel-Cell Vehicle & Equipment Manufacturers Industrial Hydrogen Users Backup Power & Energy Systems Testing, Certification & Safety Organizations Development Status: TRL 6 US Patent No. 10,490,833 B1 LA-UR-25-32317 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology https://www.lanl.gov/engage/collaboration/feynman-center/tech-and-capability-search
68%
Special Notice02/12/2026
Unlike conventional multichannel atomic magnetometers that require one vapor cell and one optical system for each sensing channel, the patented Multi-Channel Atomic Magnetometer (MCAM) architecture from Los Alamos National Laboratory replaces many independent atomic magnetometers with a single shared vapor cell and optical system that simultaneously generates multiple independent sensing channels. MCAM is a non-cryogenic multi-channel optical quantum sensor in a single module that captures ultra-faint biomagnetic signals from the brain, heart and other sources with sensitivity approaching that of the cryogenic SQUID-based systems that have defined the field for decades. MCAM delivers that performance at roughly one-tenth the per-channel cost without a drop of liquid helium. The module pairs one large alkali-metal vapor cell with broad pump and probe laser beams read out by a photodiode array, providing 16 independent sensing channels in a single housing, scaling into helmet-style arrays of hundreds of channels, and flexing around the patient rather than forcing the patient into a fixed cryogenic dewar. Together, these attributes more easily allow for magnetoencephalography, magnetocardiography and magnetic-particle imaging while accelerating overall magnetic imaging workflows. Ongoing development is aimed at extending the sensing architecture from the centimeter scale characterized in the current prototype toward micrometer-scale spatial resolution, opening a path into cellular-scale magnetic imaging that current cryogenic and room-temperature arrays cannot address. How it Works The MCAM module operates on the spin-exchange relaxation-free (SERF) regime, in which atomic spins of alkali-metal atoms inside a large, sealed vapor cell are aligned by a circularly polarized broad pump laser beam through optical pumping and then interrogated by a linearly polarized broad probe beam propagating along a nearly parallel path. An external magnetic field of interest tilts the aligned atomic spins by an angle proportional to the field strength, and that tilt rotates the polarization plane of the probe beam through the Faraday effect; a photodiode array reads the optical rotation simultaneously at multiple points across the cell, with each photodiode pixel reporting on its own localized sensing volume. A buffer gas inside the cell restricts atomic motion so that the small cell volumes behind each pixel behave as independent sensing channels, a rear mirror folds the beams back through the cell to shorten the stand-off distance to the magnetic source, and transparent Pyrex wire heaters hold the cell at the operating temperature needed for SERF operation. Technology Description The patented shared-cell architecture generates multiple independent sensing channels from a single vapor cell, a single pump beam, a single probe beam, and a single detector array. A pair of broad, co-propagating laser beams, one for optical pumping and the other for probing, traverses the shared vapor cell to manipulate the internal atomic spins, converting the local magnetic field distribution into a spatially resolved optical signal that is read out by a multi-pixel photodetector. Because the buffer gas inside the cell restricts atomic diffusion, each pixel of the detector reports on its own small, spatially distinct region of the cell; therefore, the single module yields a two-dimensional map of the local magnetic field rather than a single-point measurement. Operation in the SERF regime, together with an integrated heating and shielding arrangement and a fold-back optical geometry that shortens the distance from the sensing volume to the magnetic source, sets the sensitivity floor in the low tens of femtotesla per root hertz at low frequency. A development path has been identified to reduce the effective sensing-volume scale from the roughly 1 cm per-channel footprint of the current prototype toward the 1 μm range, which would extend the platform from whole-organ mapping into micro-scale magnetic imaging regimes. Architecturally, the MCAM module is engineered for arrays. Because all channels within a single module share one vapor cell, one laser pair, and one optics assembly, the per-channel parts count and tuning effort drop sharply versus designs that stack many single-channel sensors. Fiber-optic coupling between the laser sources and each sensor head lets modules be repositioned independently, so many modules can be tiled into a conformal helmet or surface array that adapts to head or torso shape and supports configurations that rigid large-cell predecessors cannot accommodate. The design is compatible with several alkali-metal and buffer-gas options and with per-module bias coils that allow each module to be tuned individually inside a larger array. Advantages Development path toward micrometer-scale spatial resolution, a roughly four-order-of-magnitude improvement over the current centimeter-scale prototype and an enabler of cellular-scale magnetic imaging Sensitivity at the low tens of femtotesla per root hertz, comparable to cryogenic SQUID arrays, while using a warm vapor, non-cryogenic architecture Roughly tenfold per-channel cost reduction by sharing one vapor cell, one laser pair and one optics set across 16 channels No liquid cryogens, eliminating recurring cryogen costs and simplifying siting, maintenance and shielding Fiber-coupled, repositionable sensor heads that conform to the patient rather than forcing the patient into a fixed dewar Scalable into helmet-style arrays of hundreds of channels, including a size-adjustable pediatric configuration Shorter sensor-to-source stand-off via rear-mirror beam folding, sharpening spatial resolution of biomagnetic sources Market Applications Medical Diagnostic Imaging (magnetoencephalography systems for epilepsy, stroke and neurodegenerative workups; magnetocardiography for arrhythmia and ischemia screening) Pediatric and Adaptive Neuroimaging (size-adjustable MEG helmets, point-of-care brain monitoring) Micro-scale Biomagnetic Imaging (single-neuron and small-circuit brain activity mapping, high-resolution cardiac tissue mapping) Cancer Diagnostics (magnetic nanoparticle imaging for tumor localization and targeted-therapy tracking) Magnetic Resonance Imaging (low-field/ultra-low field, portable MRI, functional brain imaging) Sensing (low-frequency antennas for underground or undersea links, geomagnetic surveying) Instrumentation (fundamental physics, biomagnetism laboratories, multichannel sensor R&D) Development Status: TRL 4 U.S. Patent No. 11,105,865 LA-UR-26-25904 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
66%
Special Notice12/13/2026
The Naval Air Warfare Center, Aircraft Division (NAWCAD) Lakehurst, NJ intends to negotiate on a sole source basis with D-2 Incorporated, CAGE: 4EKX8 for a Firm-Fixed-Priced contract. This procurement is to acquire Hydraulic Fluid Particle Counters, Part Number (PN) 4348AS1000-1, National Stock Number (NSN): 6635-01-725-8375 in support of the United States Navy (USN) MQ-4C Program. The Hydraulic Fluid Particle Counter is used to verify hydraulic fluid cleanliness in aircraft and support equipment by detecting and classifying particulate contamination to ensure compliance with established contamination and control standards. The Hydraulic Fluid Particle Counter is solely manufactured and distributed by D-2 Incorporated as the Original Equipment Manufacturer (OEM), who has confirmed that they do not have authorized distributors. The OEM owns the proprietary rights to the drawing and design of this equipment and is not selling any of the rights. D-2 Incorporated is the only source with the requisite knowledge, experience, technical expertise and technical data to provide the required Hydraulic Fluid Particle Counter. There are no other manufacturers or approved distributors identified that are able to meet the Government's requirement, and no other item can be sourced to meet this requirement. A solicitation will NOT be posted following the close of this synopsis, unless alternate offerors are identified. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS. However, the Government will consider all responses received within 15 days after the date of publication of this synopsis. Registration in the System for Award Management (SAM) at https://www.sam.gov is mandatory for consideration. A determination by the Government not to open this requirement to competition based on the responses to this notice will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. Information provided herein is subject to change and in no way binds the Government to solicit for an award of a contract. Responses must be received within fifteen (15) days of publication of this notice via email, no later than 3 December 2026 Eastern Time to Matthew Melon, matthew.e.melon2.civ@us.navy.mil.
66%
Pre-Solicitation12/03/2026
COMBINED SYNOPSIS / SOLICITATION FOR COMMERCIAL PRODUCTS SOLICITATION NUMBER: N0042127Q1020 ACTION CODE: Combined Synopsis/Solicitation POSTING DATE: 16 November 2026 RESPONSE DUE DATE: 20 days after posting at 12:00 PM EST CONTRACTING ACTIVITY: Naval Air Warfare Center Aircraft Division (NAWCAD), Patuxent River, MD PSC CODE: 6635 (Physical Properties Testing and Inspection Equipment) NAICS CODE: 334516 (Analytical Laboratory Instrument Manufacturing) / Size Standard: 1,000 Employees SET-ASIDE: Full and Open Competition (Unrestricted) (i) This is a combined synopsis/solicitation for commercial products prepared in accordance with the format in Federal Acquisition Regulation (FAR) Part 12, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. (ii) Solicitation number N0042127Q1020 is issued as a Request for Quotation (RFQ). (iii) The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2026-03 and Defense Federal Acquisition Regulation Supplement (DFARS) current publication. (iv) This procurement is unrestricted under full and open competition. The North American Industry Classification System (NAICS) code is 334516, Analytical Laboratory Instrument Manufacturing, with a small business size standard of 1,000 employees. The Product Service Code (PSC) is 6635. (v) Schedule of Supplies/Services: The Government intends to award a single Firm-Fixed-Price (FFP) purchase order. The contract line item numbers (CLINs) and quantities are as follows: - CLIN 0001: X-ray Computed Tomography (CT) System (Hardware & Software), Qty: 1 EA - CLIN 0002: Phased Training Program (Phases 1, 2, and 3), Qty: 1 Lot - CLIN 0003: Preventative Maintenance & Warranty (Base Year - Months 1-12), Qty: 1 Lot - CLIN 1001 (Option Year 1): Preventative Maintenance & Warranty (Months 13-24), Qty: 1 Lot (vi) Description of Requirements: The Naval Air Warfare Center Aircraft Division (NAWCAD), Patuxent River, MD has a requirement for a turnkey, dual-tube (225kV micro-focus and 450kV high-resolution) X-ray Computed Tomography (CT) system housed in a CFR 1020.40 compliant shielded enclosure. Full technical specifications and performance requirements are detailed in the attached Statement of Work (SOW). (vii) Period of Performance and Delivery: - Delivery and complete installation of the CT system, software, and Phase 1 training: No later than 12 months after contract award (Target: 9 months). - Off-site Theory Training: No later than 18 months after contract award. - Place of Delivery and Performance: Naval Air Warfare Center Aircraft Division, Building 2933, Patuxent River, MD 20670. FOB Destination. (viii) FAR 52.212-1, Instructions to Offerors - Commercial Products and Commercial Services, applies to this acquisition. Addenda to 52.212-1 are included in the attached SF 1449 solicitation package. (ix) FAR 52.212-2, Evaluation - Commercial Products and Commercial Services, applies to this acquisition. Award will be made to the responsible offeror whose quote represents the Best Value to the Government utilizing a comparative evaluation process based on two factors: Factor 1: Technical Capability (Sub-factors: Hardware Specifications, Software & Analysis Suite, Implementation & Training) and Factor 2: Price. Technical Capability is significantly more important than Price. Detailed evaluation methodology is set forth in the attached Addendum to FAR 52.212-2. (x) Offerors shall include a completed copy of the provision at FAR 52.212-3, Offeror Representations and Certifications - Commercial Products and Commercial Services, with their quote, or ensure their SAM.gov registration is current and complete. (xi) FAR 52.212-4, Contract Terms and Conditions - Commercial Products and Commercial Services, applies to this acquisition. (xii) FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders - Commercial Products and Commercial Services, applies to this acquisition. Applicable clauses are indicated in the attached SF 1449. (xiii) Additional Contract Requirements: All questions regarding this RFQ must be submitted via email to the Contracting Points of Contact listed below no later than five (5) days after posting at 12:00 PM EST. (xiv) Defense Priorities and Allocations System (DPAS): DO-A7 rated order (if applicable). (xv) Submission of Quotes: Quotes are due no later than 20 days after posting at 12:00 PM EST. Quotes must be submitted electronically via email to: - Primary POC: Jasmine McCree, Contract Specialist, jasmine.a.mccree.civ@us.navy.mil - Secondary POC: Stacey Stone, Contracting Officer, stacey.l.stone9.civ@us.navy.mil (xvi) Attachments: 1. Standard Form 1449 Solicitation Package (with Terms, Conditions, and Addenda) 2. Statement of Work (SOW) - Turnkey Dual-Tube Computed Tomography (CT) System
66%
Combined Synopsis12/07/2026

Additional Details

Solicitation Number

N4215824QE081

Archive Date

Sep 21, 2024

Office Address

PORTSMOUTH, VA, 23709-1001