GovChime
Notice ID: c534b4c05ee347c39600439fde06df25Combined Synopsis/SolicitationArchived

Inspect, Diagnose, Repair 7890B Gas Chromatograph w/ Flame Ionization Detector

Archived on April 8, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM PDT
Posted
March 19, 2025
Notice type
Combined Synopsis/Solicitation
NAICS
811210: Electronic and Precision Equipment Repair and Maintenance
Agency
Department of WarDepartment of the Navy

Notice details

Office
PUGET SOUND NAVAL SHIPYARD IMF
Place of performance
Bremerton, WA, 98314
Last updated
Nov 17, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
N4523A25Q6007
Notice ID
c534b4c05ee347c39600439fde06df25

Description

This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with the format in subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. DESCRIPTION: Inspect and repair services for 7890B Gas Chromatograph (GC) with Flame Ionization Detector (FID) to bring equipment to a functional state. Functional state is defined by the following: FID flame is able to light. FID signal reads 0 Hz when the detectors electrometer is turned off. FID signal increases when the detectors electrometer is turned on. FID signal changes in response to changes in the flow of gases applied to the FID (real-time responsiveness to applied stimuli) The below parts will be installed into the GC/FID if the currently installed part is determined to be defective. 7890B GC/FID parts: FID interface board FID electrometer PCA FID interconnect assembly FID collector assembly The Vendor is to provide a quote (Including parts and labor) for any additional recommended repairs.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

Files (3)

  • C08.0 Combined Synopsis Solicitation_Gas Chromatograph_final.pdf

    371 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • A04.01 PWS (GC-FID Repair)_final_Redacted.pdf

    268 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • A11_WageDetermination_2015-5525_06MAR2025.pdf

    4.8 MBAdded in Combined Synopsis/Solicitation version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    Inspect, Diagnose, Repair 7890B Gas Chromatograph w/ Flame Ionization Detector

    Notice c534b4c05ee347c39600439fde06df25 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

N4523A25Q6007

Archive Date

Apr 8, 2025

Office Address

BREMERTON, WA, 98314-5001