Notice ID: e82e9c660dfe860402b0458194ca8053Combined Synopsis/Solicitation
J--Service, Repair, preventative maintenance, and semi-annual test inspections for ACS, IDS, and Badging repair in Fallon, Nevada
Archived on April 7, 2018. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 AM UTC−05:00
- Posted
- April 4, 2018
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- Agency
- Department of WarDepartment of the Navy
Notice details
- Office
- NAWC TRAINING SYSTEMS DIV
- Place of performance
- 4755 Pasture Rd Bldg. 406, Fallon, NV 89406 US
- PSC
- J: MAINT, REPAIR, REBUILD EQUIPMENT
- Last updated
- Sep 10, 2025
Identifiers
- Solicitation number
- N6134018Q0009
- Notice ID
- e82e9c660dfe860402b0458194ca8053
Description
The Government requires service, repair, preventative maintenance, and semi-annual test inspections of the Access Control System (ACS) which includes a badging system (computer/printer/camera), and the Intrusion Detection System (IDS) located at Naval Air Station (NAS) Fallon, Nevada. The current IDS security system requires semi-annual test inspections and the ACS workstation requires periodic patching and may require repair in the event of a system malfunction. (Any on-site repairs would be negotiated as part of the Over-and-Above CLIN and do not need to be included in initial proposal. Parts list has been attached as a point of reference for what equipment is to be supported.) Below is a description of the requirement (See SOW and Combined Synopsis-Solicitation for full detailed requirement): The Government requires service, repair, preventative maintenance, and semi-annual test inspections of the Access Control System (ACS) which includes a badging system (computer/printer/camera), and the Intrusion Detection System (IDS) located at Naval Air Station (NAS) Fallon, Nevada. The current IDS security system requires semi-annual test inspections and the ACS workstation requires periodic patching and may require repair in the event of a system malfunction. a. The contractor shall comply with ICS 705-1 and IC Tech Spec version 1.4 for security system maintenance and testing. b. The contractor shall provide 24 hours a day, 365 days a year phone support able to initiate repairs/establish priority within 4 hours of a trouble signal or a request for service. c. The contractor shall insure services conducted under this contract are performed by U.S. citizens. d. The contractor shall provide documentation for maintenance repairs and inspections within 30 days of completion. e. The contractor shall provide training within 30 days of contract award for the operation of the C Cure 9000 software to include making badges. The maintenance for the NAS Fallon, Nevada shall include all components of the ACS to include the badging system (computer/printer/camera) and IDS. a. The contractor shall ensure service requests classified emergency are resolved within 24 hours. b. The contractor shall ensure service requests classified non-emergency are resolved within 48 hours. c. The contractor shall test the system and backup batteries in accordance with the manufacturer’s periodic maintenance schedule and procedures. d. The contractor shall replace batteries in accordance with the manufacturer’s recommendations or as environmental conditions dictate. e. The contractor shall evaluate the ACS Operating System (OS) and C∙Cure 9000 software is current. The contractor shall upgrade the ACS OS and C∙Cure 9000 software to the latest versions as necessary. CURRENT VERSION: 2.50.2462.0251 (C-Cure is only connected to the ACS workstation, NOT the IDS.) Software House C Cure-9000 is the operating system for all. Semi-Annual Inspection Requirements a. The contractor shall perform semi-annual inspections for the NAS Fallon, Building 406 (ADSGF) in accordance with IC Tech Spec ver.1.4 (28 Sep 2017) and include all areas/components of the ACS and IDS. b. The contractor shall provide documentation of completed inspections within 30 days of event completion (CDRL A001). c. The contractor shall ensure inspections are witnessed by ADSGF Government Personnel (Proof of U.S. Citizenship required. Security clearance is not required.)
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
N6134018Q0009- Combined Synopsis
- 10×Combined SynopsisCurrentMar 21, 2018
J--Service, Repair, preventative maintenance, and semi-annual test inspections for ACS, IDS, and Badging repair in Fallon, Nevada
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
N6134018Q0009
Archive Date
Apr 7, 2018
Office Address
ORLANDO, FL, 32826-3224