Y--IDIQ MACC SBSA FOR NEW CONSTRUCTION, RENOVATION, AND REPAIR OF WET UTILITIES CONSTRUCTION PROJECTS AT VARIOUS GOVERNMENT INSTALLATIONS
Awarded on November 14, 2018. Full description on SAM.gov.
Overview
- Posted
- November 15, 2018
- Notice type
- Award Notice
- NAICS
- 237110: Water and Sewer Line and Related Structures Construction
- Agency
- Department of War
Notice details
- PSC
- Y: CONSTRUCT OF STRUCTURES/FACILITIES
- Last updated
- Sep 10, 2025
- Award date
- Nov 14, 2018
- Award amount (SAM.gov award notice)
- $5.0K
Identifiers
- Solicitation number
- N6247317R4624
- Notice ID
- 7d09c37a581bc884ace5cb19956a72e9
- Award number (PIID)
- N62473-19-D-1207
Description
Award Overview
Award Number
N62473-19-D-1207
Award Amount (SAM.gov award notice)
$5.0K
Award Date
Nov 14, 2018
Awardee
Awardee UEI
JNGMKR7BRV13
Original Solicitation
Notice ID: 7d09c37a581bc884ace5cb19956a72e9
Posted Date: Nov 15, 2018
Original Response Deadline: Not specified
Task Orders Under This IDV
Top 10 by total obligated
- $12.1MSigned Jul 17, 2025
- $11.0MSigned Sep 11, 2024
- $11.0MSigned Sep 8, 2022
- $10.9MSigned Apr 24, 2025
- $10.9MSigned Jul 25, 2024
- $5.3MSigned Aug 31, 2023
- $5.3MSigned Oct 10, 2023
- $5.3MSigned Mar 5, 2020
- $5.0MSigned Oct 6, 2021
- $4.9MSigned Mar 24, 2021
More From This Vendor
Top 5 most recent
- —Signed May 29, 2026
- $1.4MSigned Dec 3, 2025
- —Signed Aug 28, 2025
- $883.1KSigned Aug 22, 2025
- $12.1MSigned Jul 17, 2025
Contacts
Documents
No documents available.
Lifecycle
N6247317R4624- Pre-Solicitation
- Solicitation
- Awarded
This opportunity has been awarded.
- 2×Pre-SolicitationDec 28, 2016
Y--INDEFINITE DELIVERY INDEFINITE QUANTITY (IDIQ) MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) FOR WET UTILITIES PROJECTS AT VARIOUS GOVERNMENT INSTALLATIONS IN CA, AZ,NV, CO AND NM
- SolicitationJan 30, 2017
Y--INDEFINITE DELIVERY INDEFINITE QUANTITY (IDIQ) MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) FOR WET UTILITIES PROJECTS AT VARIOUS GOVERNMENT INSTALLATIONS IN CA, AZ,NV, CO AND NM
- 7×AwardedCurrentNov 14, 2018
Y--IDIQ MACC SBSA FOR NEW CONSTRUCTION, RENOVATION, AND REPAIR OF WET UTILITIES CONSTRUCTION PROJECTS AT VARIOUS GOVERNMENT INSTALLATIONS
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Login at https://piee.eb.mil and search for 'N6247322RX011' to obtain more details.* | - | Solicitation | 10/27/2026 |
REQUEST FOR INFORMATION (RFI) / MARKET INTELLIGENCE NOTICE This is a Request for Information (RFI) for market intelligence and for informational purposes only. This announcement does not constitute a Solicitation or a Request for Proposal (RFP), and no solicitation is currently available. Participation in this RFI is strictly voluntary. The Government will not be obligated to award any agreement or contract because of this RFI, nor will it reimburse respondents for any costs associated with the preparation or submission of information. Submitting a response will not affect a firm’s ability to submit a proposal should formal solicitation be issued in the future. NAICS Code: 237110 – Water and Sewer Line and Related Structures Construction (Note: While Other Transaction Authority is not subject to FAR-based small businesIntells regulations, this NAICS code is provided for market research to help the Government understand the size and demographics of the interested industrial base.) Small Business Size Standard: $45 Million PROJECT OVERVIEW The U.S. Army Corps of Engineers (USACE), Louisville District, has a requirement for the design and construction of a project to restore and modernize the potable water system and wastewater collection system throughout the Fort Hunter Liggett Installation. The scope of work consists of furnishing all necessary design services, equipment, materials, labor, construction management, supervision, quality control, and supplies to deliver a fully functional and modernized potable water and wastewater systems on the Installation. The Fort Hunter Liggett water distribution system dates back to the 1950’s with a few areas believed to be even older and includes a three (3) well configuration that has sufficient pumping capacity to serve current supply demands, however, the water transmission system is undersized to satisfy the demand of the system. While the current water system storage may be sufficient for normal operation, it cannot sustain the system for more than one day in the event of a pump outage and/or fire flow event during maximum day conditions; therefore, additional system storage is necessary. A new Tank Farm with adequate storage capacity (estimated to be a minimum of 2 million gallons) to be determined and validated in accordance with NSPC, UFC, and NFPA criteria, should be in vicinity of security fence gate 10 (Lat: 35.997638° , Long: -121.224355°). Currently the primary storage tank for the potable water system is on the opposite side of the cantonment from the wells and the transmission main and distribution are combined causing significant pressure variations far in excess of industry standard, causing accelerated deterioration of system components. Many pipelines, valves, and hydrants within the distribution system have currently exceeded their useful life expectancy and have failed or failing. High operating pressures place additional strain on this aging system, requiring operational improvements as well as rehabilitation/replacement of existing assets. Modernizing SCADA components are necessary to increase efficiency and updated to cover any system revisions and future improvements. SCADA infrastructure improvements shall integrate into the existing SCADA infrastructure. Fort Hunter Liggett’s wastewater collection system was installed around the same time as the water potable system. Due to the age of the system and deterioration, replacement and rehabilitation of sanitary sewer lines, manholes, and the waste treatment plant lagoon are needed to return the system to be fully functional and code compliant. The wastewater treatment plant relies on a series of lagoons to treat sewage. There are lagoons that have operational deficiencies and require the replacement of the impermeable liner. In addition, the lagoon currently lacks baffles, which are essential for directing the flow of wastewater in a way that maximizes treatment time and prevents "short circuiting". Estimated Acquisition Magnitude: $70-$80M PRIMARY ACQUISITION STRATEGY UNDER EVALUATION: Progressive Design Build (PDB) via Other Transaction Authority (OTA). The Louisville District is evaluating a Progressive Design Build (PDB) strategy utilizing an Other Transaction (OT) Agreement under the authority of 10 U.S.C. § 2808a. This authority authorizes transactions other than standard contracts to carry out facility repair and construction projects – including planning, design, engineering, piloting and execution – enabling early contractor involvement, commercial pricing transparency, and schedule and cost efficiencies. Currently, the Government has advanced a conceptual design for the following potable water system features below. New transmission main to connect the existing well field to the main distribution system within the cantonment area. New storage infrastructure as required to satisfy requirements for fire safety, emergency needs, and operational storage. Upgrades to existing water supply wells to enhance water-supply reliability and redundancy. A Technical Assessment Report of the condition of Fort Hunter Liggett’s utilities systems and modernization recommendations of the water and sanitary sewer systems was completed in June 2024. The onsite assessments used in developing the Technical Assessment Report were conducted November 28-December 7, 2023. Therefore, the Government is utilizing this RFI to assess industry capability, interest, and the advantages of utilizing PDB utilizing an OT Agreement under the authority of 10 U.S.C. § 2808a. The PDB Course of Action (10 U.S.C. § 2808a): The evaluation process for selection of the most highly qualified design-builder would be qualifications based. A streamlined, two-step Qualifications-Based Selection would occur: Step 1: White Papers/Statement of Qualifications submission. Step 2: Down selected design builders would be invited to Pitch Meetings/Presentations. Most highly qualified firm following pitch meetings would be selected to enter into negotiations. The OT Award would be two phases: Phase 1 (Design & Pre-Construction): The Government team will negotiate the price of Agreement Phase I – Design and Pre-Construction Services with the selected design-builder. work collaboratively to advance the design, conduct open-book cost estimating, and mitigate project risks. Phase 2 (Construction): Upon reaching an agreed-upon level of design (e.g., 60% to 90%), the Awardee will propose a Guaranteed Maximum Price (GMP). If the GMP is accepted, the Government will exercise Phase 2 for construction execution. If a GMP cannot be agreed upon, the Government retains an "off-ramp" to complete the design and construct the facility via alternative methods INFORMATION REQUESTED Interested parties are requested to respond to the following questions to help shape the final acquisition strategy. Responses shall be made using the link or QR code in the attachment: Company Profile: Q1. Firm Name Q2. Address Q3. Point of Contact (Name, Title) Q4. Phone Number Q5. Email Address Q6. Unique Entity ID Q7. CAGE code Q8. Socioeconomic Status (Other Than Small, Small, 8(a), SDVOSB, etc.) Q9. Participating Role (Prime Contractor, Subcontractor, Design Firm, Other) Other Transaction Authority (OTA) & Collaborative Delivery Experience: Q10. OTA Experience: Describe your firm's previous experience (if any) executing projects utilizing OTA. Q11. Collaborative Delivery Experience: Describe your experience executing Construction Management at Risk (CM@Risk), Progressive Design Build (PDB), Integrated Design and Construction (IDAC), Early Contractor Involvement (ECI) or other highly collaborative delivery methods. Fort Hunter Liggett Waterline Q12. Describe your experience/expertise with water and wastewater utility construction. Q13. What are the greatest supply chain, scheduling, or technical risks you foresee on a project of this type at Fort Hunter Liggett, and how could the PDB delivery method help mitigate? Feedback on the Acquisition Strategy & Alternatives: Q14. What project characteristics make PDB particularly advantageous or disadvantageous for this requirement? Q15. Does the proposed PDB-OTA strategy incentivize your firm to participate? Why or why not? Q16. Are there alternative acquisition strategies, phasing approaches, or commercial practices the Government has not considered that would yield a better facility, faster delivery, or lower cost? Q17. Differentiating Evaluation Criteria: To differentiate high-performing collaborative design builders from traditional low-bid general contractors, what evaluation criteria (e.g., past collaborative-delivery, technical approach, key personnel/superintendent experience, trade-partner/subcontractor open-book engagement strategy, or proposed General Conditions fees) should carry the greatest weight in the Government's evaluation? Bonding Capability: Q18. Project Bonding Capacity: Specify your maximum bonding (Single and Aggregate) as a Sole Prime Contractor and/or as a Joint Venture. SUBMISSION INSTRUCTIONS Submission Requirement: The only authorized transmission method of responses is via filling out the survey form. No other transmission method will be accepted. Please limit your capability statement to the space provided within the form. The Market Intelligence Response Form can be accessed at: https://forms.osi.apps.mil/r/Lmjbdft8rU or via the QR Code provided in the attachment. Please submit your responses by 03 November 2026 at 1:00 PM Eastern Time. The questionnaire is the Government's primary mechanism for obtaining detailed market intelligence and addresses industry capability, experience, technical capabilities, construction considerations, and recommended OTA and commercial practices. The Government welcomes candid industry feedback and recommendations regarding commercial practices, agreement terms, project phasing, risk sharing, governance, pricing approaches, and other considerations that could improve successful execution of this project under 10 U.S.C. § 2808a. Interested firms are encouraged to add themselves to the Interested Vendors List associated with this announcement on SAM.gov to receive future updates. Note: Do not submit proprietary trade secrets, protected technologies, or classified information in your response. All feedback received will be handled as public market research to shape the Government's final acquisition approach. | - | Market Research | 11/03/2026 |
This Sources Sought Notice is being issued for market research purposes to determine the availability, capability, and interest of small business firms for a potential Government requirement. NO SOLICITATION IS AVAILABLE; requests for the solicitation will go unanswered. No award will be made from this Notice. Responses will be used to determine potential acquisition strategies, understand current market capabilities, and to gain knowledge of potential sources. The United States Army Corps of Engineers (USACE) Sacramento District (SPK) anticipates a potential requirement for Design-Bid-Build (DBB) construction services to conduct Copper Cove Wastewater Treatment Plant (CCWTP) Improvements in collaboration with the Calaveras County Water District (CCWD) in Calaveras County, California (CA). The project is anticipated to include installation of a new continuous backwash filtration system to replace an existing filter system; electrical improvements to include upgrading the existing PG&E service size to the main switchboard located in the Control Building, installing a new transformer, raceways, metering panel, new Motor Control Center (MCC), and associated wiring and components; interconnection with a pre-existing CCWD-installed suspended air floatation (SAF) filter pretreatment system; installation of a new continuous backwash filter system to include excavation, shoring, and backfill for a partially buried cast-in-place concrete tank with three (3) equipped filter cells (modules), air control panel, grating and handrailing over the filter cells and feed channel; inlet and outlet piping, valves, and connection to existing ultraviolet (UV) inlet piping; and power and control tie-ins. The project is also anticipated to include construction of a new masonry compressor building on a concrete slab foundation, housing a duplex air compressor with space for an additional unit, along with appurtenant equipment on the compressed air piping including a refrigerated air dryer, oil-water separator, and air filter; a new wet well and submersible pump station to include a new buried precast wet well with an adjacent valve vault housing a duplex submersible pump station, valves and appurtenances, piping, and power control conduits constructed adjacent to the new SAF to convey filter backwash waste flow to the SAF. Finally, the project is anticipated to include demolition and disposal of the existing adsorption clarifier and mixed media filter equipment, dewatering of sludge handling facility solids in three (3) containerized, polymer-assisted gravity sludge dewatering systems that will be positioned on a concrete pad with containment walls and drainage systems to capture drained water and return it to Pond 6 through three (3) quick coupler hose connection points (one (1) per bin), and all associated yard pipe modifications to connect the new components to the existing WWTP, generally buried in suitable native or engineered backfill at depths of approximately three (3) to ten (10) feet of cover. The potential requirement may result in a firm-fixed-price construction solicitation issued approximately December 2026. If solicited, the Government intends to award the anticipated requirement by approximately March 2027. The Government estimates that construction of the anticipated requirement can be completed within three-hundred-sixty-five (365) calendar days from Contractor receipt of the Notice to Proceed. Work may also be impacted by bird nesting season, which runs from 1 February through 31 August. If market conditions indicate the estimated period of performance may be unrealistic, Respondents are encouraged to provide specific information (such as known equipment lead times or other timeline concerns) for Government consideration when responding to this Sources Sought Notice. The Government currently estimates the target price range for the anticipated project may be between $5,000,000.00 and $10,000,000.00. The North American Industrial Classification System (NAICS) code identified for the anticipated requirement is 237110, Water and Sewer Line and Related Structures Construction. The small business size standard for the NAICS, as established by the U.S. Small Business Administration, is $45,500,000.00 annual revenue. The Product or Service Code (PSC) for the anticipated requirement is Y1PD, Construction of Waste Treatment and Storage Facilities. If there is a reasonable expectation that two (2) or more responsible small business concerns under the NAICS can provide the anticipated services, the Contracting Officer is required to set the acquisition aside for small business concerns. If competition is set-aside for competition limited to small businesses, Federal Acquisition Regulation (FAR) 52.219-14, Limitations on Subcontracting (Deviation), requires that construction small business Contractors self-perform at least twenty-five percent (25%) of the cost of the contract, excluding the cost of materials. If no set aside is made, the requirement is competed with full and open competition, and the awarded Contractor is not a small business, the Contractor may be required to self-perform a percentage of work if required in the solicitation. Contractors with the skill, capabilities, workload capacity, and ability to obtain bonding to complete the project described above (either through self-performance and/or Subcontractor management) are invited to provide capability statements to the primary point of contact listed below. Other than small businesses are also encouraged to submit Capability Statements. CAPABILITY STATEMENT: Responses must be limited to ten (10) 8.5 x 11 inch pages with a minimum font size of point 10. Please provide the following information: 1) Company name, System for Award Management (SAM) Unique Entity Identification (UEID) number or Employer Identification Number (EIN), address, point of contact name, contact phone number, contact e-mail address, and statement identifying whether the company employs union or non-union workers. 2) Experience and capability to complete contracts of similar magnitude and complexity to the potential requirement, including at least three (3) examples of comparable work performed within the past six (6) years. Each example should include a brief description of the project, description of the work performed (identification of self-performance and/or Subcontractor management), customer name, customer satisfaction, timeliness of performance, dollar value of the project, and whether there were any challenges experienced during the project (delays, investigations, health and safety issues, labor shortages, management / organizational issues, etc.). 3) Business size and socioeconomic type for the applicable NAICS (ex: Woman-Owned Small Business, Serviced-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), certified Historically Underutilized Business Zone (HUBZone), 8(a) Participant, small business, or other than small business (large business)). 4) Bonding capability (in the form of a Surety letter). Please submit all capabilities statements, information, brochures, and/or marketing material as one (1) document, limited to the page quantity above. Responses will not be considered an offer, proposal, or bid for any solicitation that may result from this Notice. Moreover, responses will not restrict the Government to an acquisition approach. This Notice is for information and planning purposes only. Respondents will not be notified of the results of any review conducted or the capability statements received. Please provide responses and/or questions by e-mail to the Contract Specialist, Costa Laliotitis, at (Constantinos.Laliotitis@usace.army.mil) by 0800 / 8:00 a.m. Pacific Time on Monday, 7 December 2026. Please include the Sources Sought Notice number W9123827X1CHG in the e-mail subject line. | - | Market Research | 12/07/2026 |
Update 0005 is to adjust the estimated solicitation issue date to on or about January 04, 2027 and estimated response date (bid opening) to on or about February 04, 2027. Update 0005 is for administrative purposes only, any official amendment will be accompanied by an SF30. Update 0004 is to adjust the estimated solicitation issue date to on or about July 20, 2026 and estimated response date (bid opening) to on or about August 20, 2026. Update 0004 is for administrative purposes only, any official amendment will be accompanied by an SF30. Update 0003 is to adjust the estimated solicitation issue date to on or about April 13, 2026 and estimated response date (bid opening) to on or about May 13, 2026. Update 0003 is for administrative purposes only, any official amendment will be accompanied by an SF30. Update 0002 is to adjust the estimated solicitation issue date to on or about March 13, 2026 and estimated response date (bid opening) to on or about April 13, 2026. Update 0002 is for administrative purposes only, any official amendment will be accompanied by an SF30. Amd 0001 to Notice to add the estimated solicitation issue date of January 23, 2026 and estimated response date (bid opening) February 24, 2026 to the notice. The work includes various maintenance access and pipeline isolation improvements along the existing Brine Discharge Pipeline (16-inch to 30-inch diameters). Construction generally includes the installation of 4 pipeline/access improvements along Goetz Road, 2 pipeline/access improvements along Winter Circle, 4 pipeline/access improvements along the Salt Creek channel and within the Salt Creek Trail, and 2 pipeline/access improvements located inside the Districts Sun City Regional Water Reclamation Facility property. The work also includes cleaning of approximately 13,140 linear feet of the existing Brine Discharge Pipeline. The work is located in the City of Menifee, Riverside County, California. This is a Small Business Set Aside acquisition. This acquisition will be conducted under Federal Acquisition Regulation (FAR)Part 14 Sealed Bid. The estimated magnitude of construction is $5,000,000 - $10,000,000. North American Industry Classification System (NAICS) code - 237110 Water and Sewer System Construction. Size Standard $45,000,000.00. BIDDERS PLEASE NOTE: This project may be delayed, canceled or revised at any time prior to issuance of solicitation, bid opening or contract award. | - | Pre-Solicitation | 02/04/2027 |
Yosemite Valley Sewer Line and Manhole Repairs - Yosemite NP - Mariposa County, CA | - | Awarded | Open |
Additional Details
Solicitation Number
N6247317R4624
Archive Date
Nov 29, 2018
Office Address
SAN DIEGO, CA, 92132-0001