GovChime
Notice ID: 7ddac39f72a448a4a588d642518ca8e8Presolicitation

Metal Works #2

Archived on September 27, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
3:00 PM UTC−04:00
Posted
September 5, 2024
Notice type
Presolicitation
NAICS
332999: All Other Miscellaneous Fabricated Metal Product Manufacturing
Agency
Department of WarDepartment of the Navy

Notice details

Office
NSWC PHILADELPHIA DIV
Place of performance
Philadelphia, PA, 19112
Last updated
Dec 4, 2025

Identifiers

Solicitation number
N6449824Q5183
Notice ID
7ddac39f72a448a4a588d642518ca8e8

Description

The Naval Surface Warfare Center Philadelphia Division intends to procure metalwork components associated with Unit 12 assembly to be used for CLB Sched A development in accourdance with NAVSEA drawings on a full and open competition basis. Due to the subject matter of this requirement, those interested in obtaining the Request for Quotations (RFQ) shall submit a copy of the DD Form 2345 Joint Certification Program (JCP) Certificate via email to the contact below by 9/12/2024. Upon receipt of the JCP Certification and end of pre-solicitation period, the RFQ will be sent out along with a separate email of the drawings to the email listed point of contact and location. This procurment is Firm Fixed Price and will be issued using Simplified Acquisition Procedures. Please submit JCP certifications and any questions to joseph.w.aprile2.civ@us.navy.mil

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:N6449824Q5183
  1. Pre-Solicitation

Formal solicitation typically follows within 30–60 days. (estimate)

  1. Pre-SolicitationCurrentSep 5, 2024

    Metal Works #2

    Notice 7ddac39f72a448a4a588d642518ca8e8 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
This Sources Sought notice is being issued by the Naval Surface Warfare Center, Philadelphia Division (NSWCPD), on behalf of the NSWCPD Division 45. The Government is seeking information regarding the procurement of a maximum of twenty (20) Electrical Hull Penetrators (EHP). Specifications are listed in the attached Sources Sought Notice. SUBMISSION OF RESPONSES: Respondents shall provide capability statements with specific information regarding their ability to provide the required materials (described in the Sources Sought Attachment) to meet Division 45 needs. NSWCPD will only accept unclassified, electronic submissions. Responses shall be submitted via email to christopher.m.mccarthy26.civ@us.navy.mil by 16:30 EST, 20 November 2026. Responses shall list N64498-RFPREQ-PD-45-0176 in the subject line. No phone calls shall be accepted. Government WILL NOT PAY for any information received, and the Government will not compensate the respondent for any cost incurred in developing the response to this notice. The Government will not release any information marked with a proprietary legend received in response to this notice to any firms, agencies or individuals outside the Government without written permission in accordance with the legend. Please be advised that all submissions become Government property and will not be returned. This is a follow up Sources Sought Notice to an Industry Day Virtual Event held on 27 October 2026. During that event the following questions were asked. Below each question is the answer to said question. Question #1: Is this 10/27 conference a virtual event via a web link or on site at Naval Surface Warfare Center Philadelphia Division (NSWCPD)? Answer #1: This event will take place on Microsoft TEAMs. You need to register on Eventbrite to access the link. Question #2: For this PRE-SOL for Columbia Class BST-1 Electrical Hull Penetrators and Transmitter Cable Assemblies, do cable assembly manufacturers need to have SUBSAFE Level 1 or 2 certification for doing hull penetrator work? Answer #2: The Electric Hull Penetrators (EHP) is Level I material within the SUBSAFE boundary and any vendor does not need to be in NAVSEA Note5000. Question #3: I looked again at the link and there are no answers or questions posted let alone a specific statement about SubSafe Level 1 or 2. It does mention “ in accordance with applicable documents in Section 2.0 and the Statement of Work” but there is no such documents on the link. Answer #3: Again to Confirm, The Electric Hull Penetrators (EHP) is Level I material within the SUBSAFE boundary and any vendor does not need to be in NAVSEA Note5000. As for the Section 2.0 Documents and Statement of Work, those have not been provided to any vendors at this time. They will be provided at the time the official Request for Proposal (RFP) goes out. The anticipated date that the RFP goes out has not been determined yet. Question #4: We would request that the solicitation be issued as full and open given the NAICS code stated. Answer #4: Our team is still evaluating whether competing the contract as full and open or set aside is the best path forward. Question #5: Previously a vendor has been shown specifications for a cable used on BST-1 (BST-1 CABLE REQUIREMENTS PER 1197262 (PC 19). Is the cable still a 2SWF-2 (Modified) and if so, is a neoprene outer jacket still mandatory? Answer #5: The cable is still required to be LS2SWU-12 which includes a polyolefin outer jacket. Additionally, this cable will require exterior armor for EMI protection. Question #6: Question for you regarding Welding NDT. Do you need us to complete the Shipbuilder's LVL3 NDT? Answer #6: Personnel qualified to LVL 2 are permitted to perform the weld NDT, the NDT inspection must be approved by LVL 3 qualified personnel. Question #7: For the section where the pressure proof caps go on, are those welded to the main body and require a QQ-N-286 weld procedure? Does NSWC-PD need to certify this weld procedure? Answer #7: Yes, the 4 receptacles are welded to the main body. The weld type is monel QQ-N-281 to k-monel QQ-N-286. For additional guidance on performing the weld, please refer to the latest revision of NAVSEA Tech Publication 278. The procedure developed using the guidance in 278 requires NSWCPD approval. NSWCPD would be looking for the vendor to submit their weld procedure specification (WPS), product quality report (PQR), and welder qualifications for approval. Attached to this Sources Sought Notice are Two Documents: A Breakdown of the sources sought notice in a word document and what is being requested with this notice A distributable guidance that helps give newcomers an initial roadmap to preparing to support work producing Level I material. An updated slideshow from the Industry Day Event with the questions asked and said answers during and immediately after the event. THIS SOURCES SOUGHT NOTICE IS FOR INFORMATIONAL PURPOSES ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. IT DOES NOT CONSTITUTE A SOLICITATION AND SHALL NOT BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT. RESPONSES IN ANY FORM ARE NOT OFFERS AND THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A TASK ORDER AS A RESULT OF THIS ANNOUNCEMENT. NO FUNDS ARE AVAILABLE TO PAY FOR PREPARATION OF RESPONSES TO THIS ANNOUNCEMENT. ANY INFORMATION SUBMITTED BY RESPONDENTS TO THIS SOURCES SOUGHT NOTICE IS STRICTLY VOLUNTARY.
-Market Research11/20/2026
The contractor shall supply twelve (12) 150,000 lbs. (75 ton) industrial work horses and six (6) 150,000 lbs. (75ton) per specifications in Section 3.0. Shipping shall be included with the price. The contractor shall deliver the Industrial Work Horses to NFPC. Delivery Location: Naval Foundry and Propeller Center 2003 Constitution Ave Building 1081 Philadelphia Navy Yard Philadelphia, PA 19112 Shipping Receiving Hours of Operation - M/F 0730-1400 Please Email Proposals to christopher.m.mccarthy26.civ@us.navy.mil and anthony.j.diplacido.civ@us.navy.mil. The following questions Were asked and below are there responses. Many questions were similar in nature and are thus being grouped together as they all have the same answer which is providing in a word document in the attachment/links section. NO QUESTIONS ASKED VIA EMAIL AFTER 3 NOVEMBER 2026 CAN BE GUARRANTED TO BE ANSWERED.
-Combined Synopsis11/18/2026
-Solicitation10/30/2026
The contractor shall fabricate, conduct certification testing, and deliver material components for the Cable Cutter and Reeling Machine Assembly. All material components are LEVEL I Material and/or Material to be installed in a SUBSAFE Boundary. The purpose of this amendment is to 1. Amend the page limits on the table in section L.3 2. Delete the table footer language: The entire Technical proposal (excluding cost or otherwise noted) shall not exceed twenty(20) pages in length. 3. Extend the due date to 12 March 2026.All other terms and conditions remain unchanged.
-Solicitation03/12/2026
Oil City, PA Ice Boom
-Combined Synopsis07/08/2026

Additional Details

Solicitation Number

N6449824Q5183

Archive Date

Sep 27, 2024

Office Address

PHILADELPHIA, PA, 19112-1403