UPS Maintenance

Archived on April 29, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
5:00 PM PDT
Posted
April 13, 2026
Notice type
Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
811210: Electronic and Precision Equipment Repair and Maintenance
Agency
Department of WarDepartment of the Navy

Notice details

Office
SSP.STRATEGIC WEAPONS FAC PAC FINANCIAL
Place of performance
Silverdale, Washington, 98315
PSC
J061: MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
N6471026Q0007
Notice ID
8373da152b364876be53dddb5256d776

Description

Statement Of Work

UPS Maintenance and Repair

  1. BACKGROUND

Strategic Weapons Facility Pacific (SWFPAC) requires comprehensive maintenance and repair service contract for three (3) Uninterruptible Power Supply (UPS) units located at SWFPAC facilities on Naval Base Kitsap-Bangor in Silverdale, WA.

The purpose of this contract is to ensure the reliable operation of critical power infrastructure through proactive maintenance and timely emergency support.

2. Equipment Covered:

Make

Model

Description

Serial Number

APC

SYCF40KF

Symmetra PX UPS 20kVA 40 and/or PDU

QD1633340704

APC

SYCF40KF

Symmetra PX UPS 40kVA 40 and/or PDU

QD1830240733

APC

SYCF40KF

Symmetra PX UPS 40kVA 40 and/or PDU

QD1830240729

  1. SCOPE:   

The contractor shall provide all-inclusive preventative maintenance, on-site emergency repair, and remote technical support for the UPS equipment listed in paragraph 2. To ensure the manufacturer's warranty remains valid, services must be delivered by an American Power Conversion (APC)-certified or authorized service provider. All components, parts, and consumables used for maintenance or repair must be new, genuine original equipment manufacturer parts that meet APC specifications.

3.1. Technical Support

The contractor shall provide 24 hours a day, 7 days a week, 365 days a year (24/7/365) telephone and email access to a technical support center for troubleshooting and service dispatch.

3.2. On-Site Support

Emergency On-Site Response: For any critical failure resulting in a loss of redundancy or an inability to support the protected load, a qualified technician must arrive on-site within six (6) hours of the service request being logged. This six (6) hour response shall be guaranteed 24/7/365.

Standard On-Site Response: For non-critical failures where the UPS remains operational, a qualified technician must arrive on-site no later than the next business day.

Parts & Labor: This contract shall cover 100% of the costs for all replacement parts, hardware, capacitors, fans, and any other components needed to restore the UPS units listed in paragraph 2 to full operational status. All associated labor, travel, and expenses for on-site visits shall be included.

Equivalent Hardware: If a failed hardware component is no longer manufactured, it shall be replaced with an equivalent or superior component that is fully compatible.

3.3. Preventative Maintenance (PM)

The contractor shall perform one (1) scheduled on-site preventative maintenance visit during the contract period. This visit shall include all UPS units listed in paragraph 2.

The PM service must include, at a minimum, the following tasks for each UPS:

  • Visual Inspection: Check for loose connections, overheating, component discoloration, and physical defects.
  • Environmental Checks: Measure and record ambient temperature and humidity.
  • Cleaning: Clean and remove dust/debris from the interior and exterior of the UPS.
  • Electrical Checks: Perform thermal scans on electrical connections to identify potential failure points. Check and tighten all terminal connections as needed.
  • Battery Maintenance: Conduct a full battery string inspection, including voltage checks, impedance testing, and a system load test to verify battery performance and runtime.
  • System Calibration: Calibrate and verify all system alarms, setpoints, and transfer mechanisms.
  • Firmware & Software: Review installed firmware and operating system software. Install any necessary updates, patches, or security fixes after receiving approval from SWFPAC personnel.
  • Functional Test: Perform a full functional test to ensure the unit operates correctly in all modes (e.g., normal, battery, bypass).

4. DELIVERABLES

The following deliverables are required:

Field Service Report: After each preventative maintenance visit or emergency repair, the contractor shall provide a detailed electronic service report within five (5) business days. This report must document all work performed, tests conducted, parts replaced, and findings or recommendations.

Annual System Health Report: At the conclusion of the contract period, the contractor shall provide a summary report detailing the overall health of the UPS fleet, a summary of service activities for the year, and recommendations for future maintenance or upgrades.

5. CONTRACTOR & PERSONNEL REQUIREMENTS

Certification: All on-site technicians must be certified by APC to work on the specified UPS models. Proof of certification may be requested.

Security & Access: The contractor and its personnel must comply with all SWFPAC security protocols, including requirements for background checks, site access, and safety procedures. The contractor will be escorted at all times unless prior arrangements are made.

Base Access: Contractors must be able to gain access to SWFPAC on Naval Base Kitsap – Bangor,

WA.  Base access may be granted using the Rapid Gate System, DBIDS System, or other approved base

access system at the Contractor’s expense.  Once base access is granted, Contractors will be required to

apply for a visitor badge (BAVR request) at https://www.bavr.cnic.navy.mil/.  Coordination of the visitor

badge will be through the Government Point of Contract.

Vehicle Pass: In order to drive a non-Government vehicle to the work location, the contractor must

submit a SWFPAC Vehicle Pass Request and required documents to the COR.  The non-Government

vehicle must be registered in the company’s name and must have a clear logo displayed on the vehicle

indicating the company it is registered to.  When entering the base, the vehicle must have the approved

vehicle pass displayed in the driver’s side windshield at all times.  No Bluetooth, telephonic, or electronic

devices are allowed in secured locations on base. 

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (3)

  • 4.0_1301328155_Solicitation Amendment - N6471026Q00070002.pdf

    2.0 MBAdded in Solicitation version 3Posted
    Download
  • 3.3_1301328155_J&A Brand Name Justification_REDACTED_Redacted.pdf

    145 KBAdded in Solicitation version 3Posted
    Download
  • 4.0_130132155_Solicitation Amendment - N6471026Q00070001_Conformed.pdf

    2.0 MBAdded in Solicitation version 3Posted
    Download

Lifecycle

  1. 1
    Version 1SolicitationArchived

    UPS Maintenance

    Notice dbf322459eff4368901db8386c41a8e5 on SAM.gov

  2. 3
    Version 3SolicitationArchivedCurrent

    UPS Maintenance

    Notice 8373da152b364876be53dddb5256d776 on SAM.gov

Other notices for this solicitation

  1. Pre-SolicitationApr 6, 2026

    UPS Maintenance

    Notice 7232c13bd3df45838b86b48d3667e3d8 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

N6471026Q0007

Archive Date

Apr 29, 2026

Office Address

SILVERDALE, WA, 98315-6499