GovChime
Notice ID: af40becf10b84441acd6a4daec01faadCombined Synopsis/Solicitation

Hanger Light Replacements

Archived on October 10, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
4:00 PM UTC−07:00
Posted
September 19, 2023
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Agency
Department of WarDepartment of the Navy

Notice details

Office
NAVAL AIR WARFARE CENTER
Place of performance
Point Mugu NAWC, CA
Last updated
Dec 4, 2025

Identifiers

Solicitation number
N6893623Q0254
Notice ID
af40becf10b84441acd6a4daec01faad

Description

The purpose of this amendment is to include 52.252-3 in section L posting of questions and answers received regarding hangar light replacements. Closing date and time of 10/10/2023 at 4:00 PM PST remains unchanged. Submit quotes via email to Beth Exzabe at Beth.a.exzabe.civ@us.navy.mil. 1 . What is the height from finished floor to highest point in Hangar? Answer: The height from floor to the interior hangar ceiling 28 01 . 2. Is the hangar clear of obstacles or is Contractor to put into price, moving of objects to get lifts in to complete work? Answer: The hangar is occupied with jets and drones. The government representatives (Rodney and Nick) will work with the tenants to move equipment around the work area and man-lift during this construction. 3. What size wire is currently feeding Lighting panel LPA ? Answer: The actual wire size from the main switchboard to panel LP is unknown. However, it is 225A panel so it should be 4#4/0 under 75C. 4. It states that the Site Safety and Health Officer may also serve as the Site Superintendent. It than states that the Quality Control can be a Roving Project Manager Does this mean that the SSHO and Superintendent are one hat and to be on-site at ALL times and the QCM does NOT have to be on-site at all times but as needed? This would mean the contractor is to put one hat into proposal? Answer:The Part 2a required a full time Superintendent and a part time (roving) QC manager. So just a superintendent will not meet the requirements of Part 2a. The QC position (second Hat) will need to be proposed, but it will not need be a full time position.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:N6893623Q0254
  1. Combined Synopsis
  1. 2×
    Combined SynopsisCurrentAug 30, 2023

    Hanger Light Replacements

    Notice af40becf10b84441acd6a4daec01faad on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

N6893623Q0254

Archive Date

Oct 10, 2024

Office Address

CHINA LAKE, CA, 93555-6018