GovChime
Notice ID: d08849b9f2658d2b6e02f93c9ef66f78Combined Synopsis/SolicitationCancelled on SAM.gov

3-axis Magnetic Field Cancelation System

Cancelled on SAM.gov (notice posted January 4, 2016). Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
1:00 AM UTC+01:00
Posted
January 4, 2016
Notice type
Combined Synopsis/Solicitation
NAICS
333517: Machine Tool Manufacturing
Agency
Department of CommerceNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

Notice details

Office
DEPT OF COMMERCE NIST
Place of performance
325 Broadway , Boulder, 80305
PSC
66: INSTRUMENTS AND LABORATORY EQPT
Last updated
Jan 23, 2026

Identifiers

Solicitation number
NB686080-16-00594
Notice ID
d08849b9f2658d2b6e02f93c9ef66f78

Description

NB686080-16-00594 3-AXIS MAGNETIC FIELD CANCELATION SYSTEM PURPOSE The Applied Physics Division (div. 686), in conjunction with the National Institute of Standards and Technology (NIST) require a 3-axis magnetic field cancelation system for a preexisting cryogenic microwave probe station recently installed at NIST Boulder. TECHNICAL SPECIFICATIONS: 1. The system must include a 3-axis sensor whose dimensions should be less than or approximately equal to 120x35x35mm. The sensor band width must be from DC to at least 100 kHz. 2. The system must be capable of nulling fields over a wide bandwidth (DC - 10kHz) with at least -40 dB attenuation at DC and -25 dB attenuation at 1 kHz. 3. The magnetic field sensor noise must be below 1nT/sqrt(Hz) for frequencies above 1 Hz. 4. The system must effectively cancel DC fields up to 70uT (given 36" square field cancelation coils). 5. System controller: the system must come with a system controller that can provide up to 6 channels of output current to control field null coils. The controller must have at least 16 bit output resolution to control coils. The controller must include a USB or RS 232 control interface. The controller must be rack mountable in a standard 19" equipment rack. 6. Coil interface and coil power: The system must include a simple interface to connect to a set of six NIST fabricating nulling coils. The maximum output power per coil must be at least 20 W/coil. 7. Software: the system must come with Windows based software to display sensed fields, set tuning parameters, and display operation parameters. TECHNICAL CONSIDERATIONS The system must be capable of nulling the earth's magnetic field, which typically varies from 25 to 65 microTesla to less than 100 nTesla. INSPECTION AND ACCEPTANCE The system must reduce both the DC and AC magnetic fields to the level specified above when installed on the existing NIST cryogenic probe station for acceptance. DELIVERABLE SCHEDULE The Contractor shall deliver no later than sixteen (16) weeks after receipt of order.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Select documents to download

Showing 4 of 4 items

Document
Source
Agency
Posted Date
File Size
Actions
Combined Synopsis/SolicitationNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGYJan 4, 2016-
Combined Synopsis/SolicitationNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGYJan 4, 2016-
Combined Synopsis/SolicitationNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGYJan 4, 2016-
Combined Synopsis/SolicitationNATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGYJan 4, 2016-

Lifecycle

Solicitation:NB686080-16-00594
  1. Combined Synopsis
  1. 2×
    Combined SynopsisCurrentDec 18, 2015

    3-axis Magnetic Field Cancelation System

    Notice d08849b9f2658d2b6e02f93c9ef66f78 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

NB686080-16-00594

Archive Date

Jan 21, 2016