Notice ID: 85be8f19834145b3b23fab107d076122Combined Synopsis/Solicitation
RECONDITIONING AND REPAIR OF 270 TON DUNHAM-BUSH SCREW CHILLER FOR NORTHEAST FISHERIES SCIENCE CENTER (NEFSC) IN SANDY HOOK, NEW JERSEY.
Archived on June 22, 2022. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 5:00 PM UTC−06:00
- Posted
- May 31, 2022
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of CommerceNATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION
Notice details
- Office
- DEPT OF COMMERCE NOAA
- Place of performance
- Highlands, NJ
- Last updated
- Dec 4, 2025
Identifiers
- Solicitation number
- NFFM7723-22-02417MCW
- Notice ID
- 85be8f19834145b3b23fab107d076122
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice and in accordance with the simplified acquisition procedures authorized in FAR Part 13. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation is being issued as a total small business set-aside. The associated NAICS code is 238220. The small business size standard is $16.5M. This combined solicitation/synopsis is for purchase of the following commercial services: Reconditioning and repair of a 270 ton Dunham-Bush Screw Chiller Description of requirements is as follows: Please refer to the attached Statement of Work for full technical specifications/requirements. See attached full Combined Synopsis with all terms and conditions which all vendors must be in compliance with to be eligible for award. Vendors must provide their Will or Will Not and Does or Does Not Statement per FAR Provision 52.204-24 which goes with FAR Clause 52.204-25. At a minimum, all quotes should include contact information and CAGE Code.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
NFFM7723-22-02417MCW- Combined Synopsis
- Combined SynopsisCurrentMay 31, 2022
RECONDITIONING AND REPAIR OF 270 TON DUNHAM-BUSH SCREW CHILLER FOR NORTHEAST FISHERIES SCIENCE CENTER (NEFSC) IN SANDY HOOK, NEW JERSEY.
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
HVAC Unit Replacement | - | Combined Synopsis | 11/20/2026 |
This notice is for Solicitation Number 36C24226R0127, Project Number 561-22-600 Upgrade Mechanical Systems-C Level at the VA NJ Health Care System, East Orange, NJ. This shall be a Service-Disabled Veteran Owned Small Business (SDVOSB) Set-Aside. As a result, all SDVOSB's may submit an offer, which will be considered by the agency. This project is classified under NAICS Code 238220 and has a size standard of $19 Million. The Magnitude of Construction for this project is between $5,000,000 and $10,000,000. Scope of Work: The scope of work shall generally consist of, but not limited to the following: Project will renovate the existing C Level utility space located at C Level of Building 1 which will provide environmentally safe, comfortable, and compliant conditions for maintenance staff. The current HVAC equipment and plumbing systems are in poor condition causing continuous water & steam leakage. The improper function of pumps is leaving the pump-pit filled with water. Newly renovated space will optimize daily activities, routine maintenance of utilities and provide safe environment for maintenance staff at C Level at VA New Jersey Health Care System East Orange Campus. Contractor shall completely prepare site for building operations, including demolition and removal of existing structures, and furnish labor and materials to perform work for VA Project 561-24-600 Upgrade Mechanical Systems-C Level as required by AE drawings and specifications, including but are not limited to: Steam Header Replacement and Distribution Condensate & Steam Piping Modification and Replacement of PRVs, Hangers & Valves Architectural and Structural Modification to Condensate Pump Pit Modification to Supply & Exhaust Air and Repair of Outside Air Intakes Hazardous Material Remediation and Insulation Repair Mechanical Room Drainage Enhancement Improvement of Lighting and Electrical Panels Refinish Surfaces, Removal of Brine Residue, Overall System Tagging/Identification and Systems Monitoring, Safety & Security. The contractor shall also furnish all labor, materials, tool, and supervision necessary to perform work for VA Project 561-22-600 Upgrade Mechanical Systems C-Level, in accordance with AE drawings and specifications. Project Completion: 430 Calendar Days from Notice to Proceed (NTP). All other details and information shall be contained in the solicitation which shall be posted on www.sam.gov. The solicitation will be released on or about November 23, 2026. The response submittal address, date and time will be included in the solicitation. This project requires bonding and all responses/submissions to the solicitation to be posted later shall be emailed. No hand-carried bids will be accepted. All prospective bidders must be currently registered in www.sam.gov , and be registered and verified as a Service Disabled Veteran Owned Small Business (SDVOSB) in https://search.certifications.sba.gov/ at the time of offer submission and before award of this procurement. End of Description. | - | Pre-Solicitation | 01/04/2027 |
Amendment 0001 posted Summary of Changes: Terms & Conditions Added bullet 8 for attachments C04 Attachment 9 – Q&A’s and Pictures Disregard questions as we are past the due date for all main questions Solicitation closing extended to November 20th, 2026 with offers due by 1500hrs MST Attachment 9 – Q&A Question and Answers from site visits and email submissions received by vendors. Statement of Work Added , 454B or R32 GWP refrigerants are also acceptable to Refrigerant requirements Updates to verbiage/requirements and information based on site visits Added Duchesne Bunkhouse floor plan and work notes, see page 20 Schedule of Items Adjusted to show correct solicitation #: 1240LR27Q0002 ****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.**** This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotatuions are being requested and a separate written solicitation will not be issued. Solicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for : BASE BID – The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to: • Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations. • Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal. • Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required. • Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding. • Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications. • Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system. • Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards. • Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition. All work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system. This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220. The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency. | - | Combined Synopsis | 11/20/2026 |
The Fort Yuma Health Center operates three EVAPCO cooling tower cells that require refurbishment of internal heat-transfer and drift-control components. The existing fill supports support the tower media/packing, which promotes even water and air distribution for heat transfer. The Government requires replacement of the fill media, fill supports, and eliminator assemblies in all three cooling tower cells to restore and maintain reliable cooling tower performance. | - | Market Research | 11/18/2026 |
HVAC Piping Insulation Project, Please see N6660427Q0490 and all attachments for complete requirement details. | - | Combined Synopsis | 11/20/2026 |
Additional Details
Solicitation Number
NFFM7723-22-02417MCW
Archive Date
Jun 22, 2022
Office Address
SEATTLE, WA, 98115