Notice ID: 3255948b75dd3fc84e0ad66e2983b896Solicitation
J--DESIGN TO REPLACE CHILLED WATER CONTROLS
Archived on January 10, 2013. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 7:00 AM UTC+02:00
- Posted
- July 24, 2012
- Notice type
- Solicitation
- NAICS
- 238210: Electrical Contractors and Other Wiring Installation Contractors
Notice details
- PSC
- J: MAINT, REPAIR, REBUILD EQUIPMENT
- Last updated
- Dec 3, 2025
Identifiers
- Solicitation number
- NNK12435778R
- Notice ID
- 3255948b75dd3fc84e0ad66e2983b896
Description
Contracting Office Address NASA/John F. Kennedy Space Center, Procurement, Kennedy Space Center, FL 32899Description NASA/John F. Kennedy Space Center plans to issue a Request for Proposal (RFP) forNNK12435778R Design to Replace Chilled Water Controls, Industrial Area, John F. KennedySpace Center, Florida. THE CONTRACTOR SHALL PROVIDE THE NECESSARY RESOURCES TO:The primary work to be performed under this project consists of installing a newdistributed programmable logic controller (PLC) based industrial process monitoring andcontrol system based upon specialized redundant servers and workstations with control andhuman machine interface capability in conjunction with supporting ancillary related fielddevices and equipment in the KSC industrial area.Primary monitoring and control equipment will be installed at KSC Building M7-407(Industrial Area Chiller Plant [IACP]). Servers, workstations and PLCs will monitor andcontrol equipment within the IACP including water chillers, chiller water pumps,condenser water pumps, condenser tower fans, air compressors, control valves andsecondary loop pumps. Most of the equipment is fully redundant and the plant generallyoperates around 5000 tons. Additionally, the servers and workstations at the IACP willalso monitor and control pumps, control valves, variable frequency drive units, andother miscellaneous equipment (including magnetic flow meters, smart temperaturetransmitters, signal isolators, protocol converters, and serial and Ethernetcommunication devices) via an Ethernet fiber optic network connected to local PLC controlsystems at the following remote facilities on the chilled water loop: M6-409 (EngineeringDevelopment Laboratory), M7-360 (Space Station Processing Facility), M7-355 (Operationsand Checkout Building), M7-505 (Payload Support Building), M7-351 (Training Auditorium),M6-399 (Headquarters Building), M6-342 (Central Instrumentation Facility), and M6-495(Occupational Health Facility).The NAICS code for this procurement is 238210 with a small business size standard of$14M. The contract effort for this RFP will include the following:Task 1 -Design to Replace Chilled Water Controls, Industrial AreaOption 1-Relocate Loop Chilled Water Control ValvesOption 2-Design-Build Replacement of Eight (8) 100 Horsepower Variable Speed Motor DrivesOption 3-Upgrade Four (4) York Chiller Control Plants The basic contract task and each option shall be separately priced. The performanceperiod for completion of all tasks and options is 730 calendar days after notice toproceed. In accordance with Federal Acquisition Regulation 36.204, Disclosure of theMagnitude of Construction Projects, the estimated price range is as follows: The total estimated cost of this project is in the estimated construction contract pricerange of between $1,000,000 and $5,000,000.The acquisition shall be conducted as a Full and Open Competition. The anticipated release date of the RFP is on or about May 30, 2012 with an anticipatedoffer closing date of on or about June 30, 2012. The firm date for receipt of bids orproposals shall be stated in the RFP. A site visit will be scheduled on or about June14, 2012. Prime contractors will be limited on the number of personnel in attendance. Specifications and Drawings will be made available for download through the postedsolicitation.All responsible sources may submit a proposal which shall be considered by the agency. An ombudsman has been appointed -- See NASA Specific Note "B". The solicitation and any documents related to this procurement shall be available overthe Internet. These documents will reside on a World-Wide Web (WWW) server, which may beaccessed using a WWW browser application. The Internet site, or URL, for the NASA/KSC Business Opportunities page ishttp://prod.nais.nasa.gov/cgi-bin/eps/bizops.cgi?gr=D&pin=76 Prospective offerors are encouraged to register their intent to submit an offer onwww.fedbizopps.gov. Search for the solicitation number and then select Add Me ToInterested Vendors. It is the offerors responsibility to monitor the Internet site forthe release of the solicitation and amendments (if any). Potential offerors will beresponsible for downloading their own copy of the solicitation and amendments (if any). All contractual and technical questions must be submitted by email. Telephone questionswill not be accepted. Point of Contact:Name: Robert Glanowski Title: Contract Specialist Phone: 321-867-0243 Fax: 321-867-2042 Email: robert.glanowski@nasa.gov
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Robert J Glanowski, Contract Specialist, Phone 321-867-7345, Fax 321-867-1166, Email robert.glanowski@nasa.gov - Lester S Howard, Contracting Officer, Phone 321-867-7432, Fax 321-867-3945, Email Lester.S.Howard@nasa.gov Robert J Glanowski
Documents
No documents available.
Lifecycle
Solicitation:
NNK12435778R- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- 5×Pre-SolicitationMay 9, 2012
J--DESIGN TO REPLACE CHILLED WATER CONTROLS
- SolicitationCurrentJul 24, 2012
J--DESIGN TO REPLACE CHILLED WATER CONTROLS
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
NNK12435778R
Archive Date
Jan 10, 2013