GovChime
Notice ID: ab4d6b0cc41e42909c812cd9c517d6a6Combined Synopsis/SolicitationArchived

Procurement of Benchtop Environmental Temp/Humidity Chamber

Archived on October 10, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EDT
Posted
September 23, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
No Set aside used
NAICS
334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
Agency
Department of Health and Human ServicesFOOD AND DRUG ADMINISTRATION

Notice details

Office
FDA OFFICE OF ACQ GRANT SVCS
Place of performance
85894, Massachusetts
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
OC-2026-136029
Notice ID
ab4d6b0cc41e42909c812cd9c517d6a6

Description

Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued. The NAICS for this requirement is: 334516. The government is not obligated to make an award. The Government is not obligated to pay costs incurred by the Contractor during quote preparation and quote submission.

Background: The FDA laboratory at the Winchester Engineering Analytical Center (WEAC) uses an environmental chamber to condition regulatory samples (such as tampons, gowns, patches, etc.) at specific temperature and humidity levels before physical testing. The chamber also supports CDRH-directed research and test method development for other medical devices received by the laboratory for analysis.
 

Minimum Performance Requirements/Salient Characteristics:

This is a Brand Name or Equal requirement. Products other than the aforementioned are acceptable but shall meet all the salient characteristics contained in the Minimum Technical Requirements below:

All of the following system requirements are minimum requirements. Equivalent requirements that differ from these minimum requirements shall be justified by the proposing vendor and evaluated by the WEAC prior to purchase:

General

The contractor shall provide an environmental chamber that uniformly conditions samples across a variety of temperature and humidity settings. The chamber must meet the following specifications:
 

  1. Temperature range: at least -20°C to 180°C
  2. Humidity range: 10% to 95% relative humidity (RH)
  3. Capacity: 4 cu. Ft.
  4. Power: Standard power cord and plug (no hardwiring)
  5. Water supply: Easily accessible water supply connection
  6. Humidity sensor: Solid-state humidity sensor
  7. Leak Detection: Must have a water leak containment and detection system
  8. Viewing window: For visual monitoring of samples
  9. Interior shelf: At least one internal shelf
  10. Mobility: Mobile cart with space-saving footprint (lab has no bench space and limited floor space for the chamber)
  11. Cable port: At least one 2-inch diameter cable port with a flexible plug
  12. Calibration: Factory calibration with an ISO 17025 certificate, or instrument calibration at start-up with ISO 17025 certificate
  13. Warranty: At least one year

Additional Specifications are included in the updated attachments

On-site Installation, Training and Commissioning

  • On-site installation and commissioning of the Environmental Chamber

Trade and Service Specification

  • All components shall be newly manufactured, not used or refurbished, and/or previously used for demonstration.
  • System installation shall occur after being received at the laboratory.
  • The entire system shall be warranted for parts and labor for a minimum of 12 months from date of formal government acceptance after on-site installation.
  • The warranty must include unlimited telephone/e-mail support for questions regarding operation.

Additional Section 508 Requirements:

      • Must meet WCAG 2.0 A and AA
      • E101.2 Equivalent Facilitation (Appendix A, Application and Scoping Requirements)
      • E203 Access to Functionality (Appendix A, Application and Scoping Requirements)
      • E204 Functional Performance Criteria (Appendix A, Application and Scoping Requirements)
      • E205 Electronic Content (Appendix A, Application and Scoping Requirements)
      • 302 Functional Performance Criteria (Appendix C, Functional Performance Criteria and Technical Requirements)
      • Electronic content must be accessible to HHS acceptance criteria. Checklist for various formats are available at https://www.hhs.gov/web/section-508/making-files-

accessible/index.html, or from the Section 508 Coordinator listed at https://www.hhs.gov/web/section-508/additional- resources/section-508-

contacts/index.html. Materials that are final items for delivery should be accompanied by the appropriate checklist, except upon approval of the Contracting Officer or Representative.

      • E208 Support Documentation and Services (Appendix A, Application and Scoping Requirements)
      • Chapter 6 Support Documentation and Services (Appendix C, Functional Performance Criteria
      • E206 Hardware (Appendix A, Application and Scoping Requirements)
      • Chapter 4 Hardware (Appendix C, Functional Performance Criteria and Technical Requirements) and Technical Requirements)
      • E207 Software (Appendix A, Application and Scoping Requirements)
      • Chapter 5 Software (Appendix C, Functional Performance Criteria and Technical Requirements)

Place of Performance:
The prospective vendor should provide insured shipping of equipment to:

U.S. Food and Drug Administration,

Winchester Engineering and Analytical Center

(WEAC)

Office of Specialty Laboratories and Enforcement Support

109 Holton Street

Winchester, MA 01890

  

Period of Performance:

Performance begins on the date of formal government acceptance and continues through the end of the manufacturer's warranty period.

Quotes are due by email on or before September 25 2026, by 12:00 P.M. (Eastern Standard Time) and should be sent to brandon.rafus@fda.hhs.gov.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (2)

  • Statement of Work- OC-2026-136029- Revised Final- 09.23.2026.docx

    20 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Combined Synopsis Solicitation- FDA-RFQ- OC-2026-136029- Revised Final-09.23.2026.pdf

    421 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    Procurement of Benchtop Environmental Temp/Humidity Chamber

    Notice 8b366130444f467bbf9556ba8ea6632a on SAM.gov

  2. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    Procurement of Benchtop Environmental Temp/Humidity Chamber

    Notice ab4d6b0cc41e42909c812cd9c517d6a6 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

OC-2026-136029

Archive Date

Oct 10, 2026

Office Address

Rockville, MD, 20852