GovChime
Notice ID: 839e811ca6cd4c409243e7ef91783d81Combined Synopsis/Solicitation

Backflow Preventers

Archived on September 26, 2026. Original response deadline: . Full description on SAM.gov.

Description

The U.S. Embassy Kingston requires the supply and delivery of backflow preventers and spares for use at the Embassy compound. This is a commercial supply acquisition in accordance with FAR Part 12 and FAR Part 13.

The Contractor shall provide backflow preventers and service kits.   The system should be certified to prevent contamination and require limited manual intervention and can be safely operated to minimize the impact on residence.  The Contractor shall provide and deliver the following items :

14 Double-Check Valve Assembly (DCVA) Backflow Preventers with Installation Kit

  1. 2 x 1.5" Lead Free Double Check Valve Assembly
  2. 2 x 2" Lead Free Double Check Valve Assembly
  3. 2 x 2.5" Lead Free Double Check Valve Assembly with service kit
  4. 6 x 3" Lead Free Double Check Valve Assembly
  5. 4 x Service Kit for 3" Lead Free Double Check Valve Assembly
  6. 2 x 4" Lead Free Double Check Valve Assembly with service kit
  7. 1 x 6" Lead Free Reduce Pressure Zone Backflow Prevention Assembly with service kit

All specialized tools, and instructions required to complete installation

All certificates of applicable standards and codes

All calibration and commissioning instructions

The Government reserves the right to reject non-conforming products.

1. Mandatory Standards and Compliance

  • ASSE 1015/CSA B64.5/cUPC: The device must meet these standards for double check valve assemblies.
  • AWWA C510: Compliant with American Water Works Association standards for double check valve assemblies.
  • NSF/ANSI/CAN 61 & 372: Must meet lead-free requirements and safe drinking water standards.
  • Hazard Rating: Suitable only for non-health hazard (low hazard) applications. 

2. Specifications (Technical Data)

  • Assembly Components: Must be factory assembled, including two check valves, two shutoff valves, and four test cocks.
  • Working Pressure: Minimum 175 psi (12.1 bar).
  • Temperature Range: 33°F to 180°F (0.5°C to 82°C).
  • Check Valve Type: Spring-loaded check valves.
  • Sizes: 3/4" to 2" bronze bodies, 2-1/2" to 10" epoxy-coated iron.
  • Shutoff Valves: Full-port resilient-seated ball valves (for sizes 2" and smaller) or non-rising stem gate valves (for sizes 2-1/2" and larger).
  • Replaceable stainless steel seats
  • Max Flow at low pressure drops
  • Ease of maintenance
  • Corrosion resistance of internals
  • No special tools required for servicing
  • Captured spring assemblies for safety

3. Common Recommended Models

  • Watts: Series LF007 (Lead Free) or Series 757.
  • FEBCO: Series 850 Small (Lead Free).
  • Ames Fire & Waterworks: Series 2000B (Small) or 2000SS

All items must be supplied with a mimum Warranty of 1 year

Delivery Terms

Delivery shall be no more than 30 calendar days after award, FOB Destination - SUVI Global Services - Doral, FL. 33178. US. The Contractor shall be responsible for all costs associated with packaging, handling, transportation and delivery.

The items should be packaged for international shipping to final destination - US Embassy Kingston - Kingston, Jamaica

Response

Quotations should be sent in USD excluding duties or taxes and must include delivery time, warranty information, detailed product specifications and certification documentation .

All firms that respond to this request for quotation must at the time of submitting their quotations must have an active registration in the System for Award Management (SAM). Interested parties should email quotations with completed NDAA889 representations to kingstonquotes@state.gov no later than the response date.

Full description on SAM.gov

Overview

Agency:
Department of State
Office:US EMBASSY KINGSTON
Posted:September 8, 2026
NAICS:238220: Plumbing, Heating, and Air-Conditioning Contractors
Last Updated:Oct 24, 2026
First published:
Last updated on SAM.gov:
PSC:4820: VALVES, NONPOWERED
Set-Aside:No Set aside used
Type:Combined Synopsis/Solicitation
Place of Performance:Kingston

Award Overview

Possible prior contracts

Sign in to see possible prior contracts for this requirement (matched by agency, NAICS and place of performance; not confirmed).

Contacts

Contracting Officer

Primary Contact

U.S. Embassy Kingston Procurement Office

Secondary Contact

Documents

Files (1)

  • PR16173182_Backflow Preventers - Questions and Answers.pdf

    110 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download

Lifecycle

  1. 1
    Version 1Combined Synopsis/SolicitationArchived

    Backflow Preventers

    Notice beb95821c4324650a530dfacd2604886 on SAM.gov

  2. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    Backflow Preventers

    Notice 839e811ca6cd4c409243e7ef91783d81 on SAM.gov

Similar Opportunities

Title
Phase
Agency
NAICS
Set Aside
Posted
Deadline
Location

Additional Details

Solicitation Number

PR16173182

Archive Date

Sep 26, 2026

Place of Performance Country

JAMAICA

Office Address

WASHINGTON, DC, 20520