GovChime
Notice ID: 404b2c2cc3dd4fb1bce2f652929b79dfPresolicitationArchived

Notice of Intent - Sole Source, SequalPrep Normalization Plates for DNA sequencing

Archived on July 23, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
5:00 PM EDT
Posted
June 23, 2026
Notice type
Presolicitation
Set-aside
No Set aside used
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of CommerceNATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION

Notice details

Office
DEPT OF COMMERCE NOAA
Place of performance
Juneau, Alaska, 99801
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
REQUIREMENTS-26-2453
Notice ID
404b2c2cc3dd4fb1bce2f652929b79df

Description

The National Oceanic and Atmospheric Administration’s (NOAA) Acquisition & Grants Office, Western Acquisition Division, intends to negotiate and award a purchase order, on a sole source basis, under authority of RFO FAR 6.103-1, with Life Technologies Corporation (UEI JXAKAG32BVN4) for SequalPrep normalization plates to standardize DNA quantity and to remove low quality short DNA fragments that can disrupt sequencing. The normalization plates are for use in next-generation sequencing protocols, including but not limited to environmental DNA (eDNA), Genotyping-in-Thousands by sequencing (GT-seq), and whole genome resequencing. NOAA requires high-quality DNA material and yields that are crucial to downstream sequencing. The normalization plates must clean up and normalize the recovery of Polymerase Chain Reaction (PCR) reaction products in one process. With 5 µl of PCR reaction, the resulting extract must be between 1.2 and 25 ng/µl of products per well within a 2- to 3-fold concentration range.

No set aside is to be used for this sole source requirement. The associated NAICS code is 334516 - Analytical Laboratory Instrument Manufacturing.

The sole source determination is based on Life Technologies Corporation being the only vendor NOAA is aware of providing normalization plates producing the extracts within the necessary concentration of DNA quantity necessary for sequencing at the quality levels required by NOAA. NOAA has conducted extensive testing on several other normalization plates with yields of insufficient concentrations to support its DNA sequencing needs. Additionally, NOAA has established and validated sequencing workflows based on SequalPrep Normalization Plates across multiple projects involving population genomics, genetic stock identification, environmental DNA, and whole-genome sequencing applications. Existing laboratory protocols, quality control procedures, automation workflows, and historical performance metrics have been developed specifically around the SequalPrep platform. Substitution of an alternative normalization technology would require extensive method development, validation, and comparison testing to demonstrate equivalency. Such efforts would increase costs, delay project timelines, consume limited sample material, and introduce uncertainty into ongoing analyses. Accordingly, NOAA has determined that the SequalPrep normalization plates provided by Life Technologies Corporation are the only responsible source to fulfill NOAA’s requirements, and no other type of supplies will satisfy those requirements.

The period of performance is anticipated to be for a twelve month base period and three twelve month optional (per FAR 52.217-7) ordering periods. During each twelve month period, NOAA intends to order a quantity of twenty (20) normalization plates. The plates must be delivered to 17109 PT LENA LOOP RD, JUNEAU, AK 99801.

This presolicitation notice is not a request for competitive proposals and no solicitation package is available. However, firms that believe they can fully meet the government's requirements may submit substantiating documentation or a request for additional information in writing to the identified point of contact within 15 calendar days after publication of this presolicitation notice. Such requests and documentation will be evaluated solely for the purpose of determining whether or not to conduct this procurement on a competitive basis. A determination by the government not to conduct a competitive procurement, based upon responses to this notice, is solely within the discretion of the government. Oral communications are not acceptable in response to this notice.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

No documents available.

Lifecycle

  1. 3
    Version 3PresolicitationArchivedCurrent

    Notice of Intent - Sole Source, SequalPrep Normalization Plates for DNA sequencing

    Notice 404b2c2cc3dd4fb1bce2f652929b79df on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Amended to include set aside code. We require an instrument that can acquire real-time data from multiple modes of measurement, including monochromator-based fluorescence, UV/Vis absorbance, and luminescence. We require the following: linear Variable Monochromator, permitting tunable band passes up to 100nm; a tunable dichroic mirror permitting air-based light path for monochromator without light guides or fiberoptics; auto ranging of detector sensitivity and gain for fluorescence measurements below 760,000,000-counts; enhanced Dynamic Range autoranging of detector sensitivity in less than 0.1s; absorbance based on a dedicated spectrometer, not a monochromator. Complete UV/Vis absorbance spectrum from 220nm-1000nm at 1nm resolution in less than 0.5s with all wavelengths captured simultaneously with a diode array; heated optics. A heated optical head means that incubated microplate wells remain in a uniform temperature environment even during detection. The instrument should have a temperature controller than can go up to 45 C, bottom reading, two reagent injectors for automated injection for initiating kinetic events and flash luminescence, and an atmospheric control unit with software-controlled CO2 andO2 concentrations for cell culture at 5% CO2. The unit should come with software for data visualization and analysis.
73%
Combined Synopsis08/06/2026
Update closing date. Updated to acquire updated quotes and pricing. Updated to include item left off original solicitation. Force Plate
60%
Combined Synopsis10/13/2026
Please see attached soliciitation.
57%
Combined Synopsis11/24/2026
Amended to add set aside code. iWorx System Required System Specifications, Minimum 18-channel data recorder with the ability to expand to additional channels. Competing systems typically provide only 2-4 channels. Ability to gang multiple recorders together for expanded data acquisition. Includes 2 channels of wireless ECG/EMG and 3-axis accelerometer capability, with expansion to 16 wired channels. Competing products generally provide only 1-2 channels. Includes an ECG simulator. Integrated Pulse Oximetry, spirometry, grip force, and intensity sensors designed for enhanced measurement accuracy. Pre-calibrated temperature, force, spirometry, and blood pressure sensors, allowing immediate use with minimal setup requirements. Two built-in low-voltage input channels (+/-15V). Built-in isolated constant current high-voltage stimulator. Must be iWire compatible, allowing future expansion and integration of additional sensors and instrumentation. Expandable to a minimum of 34 total channels. Integrated barometric pressure sensor to improve spirometry accuracy without requiring separate external hardware. Minimum 16 digital I/O channels. Minimum 1 audio output channel. Portable design capable of operation through a USB-C power connection. Includes lifetime free LabScribe software updates and an open site license. Includes unlimited online training at no additional cost.
57%
Combined Synopsis11/26/2026
Amended to add set aside code. There is a need for an incubator shaker capable of heating and mixing Erlenmeyer flasks. Flasks working volumes will be ~100 mL each. The incubator must be able to accommodate a capacity of 36 flasks simultaneously. Flasks must be able to be secured to a tray in an incubator, the incubator must be able to be heated to 30-37 deg C, and the tray in the incubator must be able to operate at 200 rpm. These flasks must be able to be heated and mixed for days at a time.
57%
Combined Synopsis11/26/2026

Additional Details

Solicitation Number

REQUIREMENTS-26-2453

Archive Date

Jul 23, 2026

Office Address

SEATTLE, WA, 98115