GovChime
Notice ID: eafbe5bea7b446e5bcb32df6de5b315bPresolicitationArchived

B706 HVAC Repair

Archived on September 26, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EDT
Posted
August 27, 2026
Notice type
Presolicitation
Set-aside
No Set aside used
NAICS
238220: Plumbing, Heating, and Air-Conditioning Contractors
Agency
Department of WarDepartment of the Air Force

Notice details

Office
AIR FORCE RESERVE COMMAND.FA6648 482 LSS LGC
Place of performance
Homestead, Florida, 33039
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
RFQ-2026-HVAC-CH-50
Notice ID
eafbe5bea7b446e5bcb32df6de5b315b

Description

This notice is issued in accordance with the Revolutionary FAR Overhaul (RFO) Part 12, specifically RFO 12.102(a) (Restricting Competition) and RFO 5.101. The Government intends to award a Firm-Fixed-Price commercial construction contract on a sole source basis to PP91 Enterprises, Inc, (UEI: TK2SC8CCNUL4), an 8(a) small business. 

The Government has a requirement for the specialized mechanical and software re-configuration of the facility's existing HVAC System . The scope of work includes, but is not limited to:

  • Re-programming and re-configuration of the chiller control sequences to align with updated building occupancy schedules.
  • Integration of the mechanical piping and variable frequency drives (VFDs) between the chiller system and the ERU dampers.
  • Testing, balancing, and commissioning of the combined HVAC/ERU loop to ensure optimal energy efficiency and air exchange metrics.
  • Verification of compliance with building automation system (BAS) communication protocols.

The Government intends to solicit and negotiate a sole-source contract with the Original Construction Contractor, for the following critical technical and warranty reasons:

  1. Warranty Integrity: The HVAC Chiller, air handlers, and ERU systems were recently installed by the Original Construction Contractor and are currently under an active, comprehensive installer and manufacturer warranty. Performing physical or software re-configuration through any third-party mechanical contractor would immediately void the remaining warranty, exposing the Government to significant financial liability for future system repairs or failures.
  2. Specialized Technical Familiarity: Having designed and built the mechanical integration of this facility, the Original Construction Contractor has unmatched technical familiarity with the custom piping geometry, flow dynamics, and specific electrical hookups of this site. Introducing a new vendor would require extensive duplicate diagnostics and system engineering, resulting in substantial duplicative costs and unacceptable delays.

Response Instructions

THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, in accordance with RFO publicizing and simplified commercial guidelines, any responsible source that believes it can fully meet the Government’s requirements may submit a capability statement, proposal, or quotation which shall be considered by the agency.

All submissions must include:

  • Company name, CAGE code, UEI, and socioeconomic status.
  • A detailed technical narrative and supporting evidence demonstrating the vendor's ability to perform the HVAC re-configuration without voiding active manufacturer warranties or requiring proprietary programming keys.
  • Pricing quote

Responses must be submitted via email to the Contracting Officer no later than 11 September 2026 at 12:00 PM EST.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

No documents available.

Lifecycle

  1. 3
    Version 3PresolicitationArchivedCurrent

    B706 HVAC Repair

    Notice eafbe5bea7b446e5bcb32df6de5b315b on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

RFQ-2026-HVAC-CH-50

Archive Date

Sep 26, 2026

Office Address