DC Power Supply
Overview
- Response deadline
- 5:00 PM PST
- Posted
- November 19, 2026
- Notice type
- Solicitation
- NAICS
- NAICS 3333 Commercial and Service Industry Machinery Manufacturing (reported as 333300)
- Agency
- Department of Energy
Notice details
- Office
- SLAC Natl Accel Lab -DOE Contractor
- Place of performance
- Menlo Park, California, 94025
- PSC
- AJ12: R&D- GENERAL SCIENCE/TECHNOLOGY: PHYSICAL SCIENCES (APPLIED RESEARCH/EXPLORATORY DEVELOPMENT)
- Last updated
- Nov 19, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- SLAC_369019_DCPowerSupply
- Notice ID
- 4d763bc71eb74c8bb6a606420b2782d2
Description
SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy. As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.
Please review the requirements and provide your best and final offer for both price and lead-time.
The following has been attached for you to complete and review:
- (BAA) Buy American Act Certification
- Representations & Certifications Rider
- Confirm attached SLAC Terms and Conditions are accepted
- Technical Specifications
Requested for Quote:
Modular, remotely controllable DC power supply system for detector electronics
Quantity: 1 EA
Please provide a price and lead time quotation by Monday, November 30, 2026.
Technical Evaluation Factors Listed Below:
- Ability to Meet the Technical Requirements: The Offeror’s proposal and supporting technical documentation will be evaluated to confirm compliance with the required detector power-supply specifications listed below.
- Schedule and Delivery Date: The University will evaluate the proposed lead time and delivery schedule against SLAC’s required project schedule. An acceptable lead time is within 30 weeks after issuance of the purchase order.
- Past Performance: The University may evaluate documentation demonstrating prior manufacturing and delivery of similar or comparable equipment. Offerors with no relevant past or present performance history may receive an “Unknown Confidence” rating.
Required item(s) are listed below:
Modular, remotely controllable DC power supply system for detector electronics
Quantity: 1 EA
Technical Requirements:
- Provide stable, low-noise, programmable DC power over at least the 30–60 VDC range.
- Support detector loads requiring up to 13.5 A and approximately 650 W per required output or load group.
- Support multiple independently controllable outputs, with the final number of outputs determined by the detector configuration and support for up to 16 outputs where applicable.
- Outputs shall be electrically isolated/potential-free where required by the detector grounding scheme.
- Provide programmable voltage and current limits, ramp rates, trip thresholds, temperature protection, and configurable fault behavior, including individual-channel and grouped-channel shutdown where needed to protect detector electronics.
- Output noise and ripple shall be sufficiently low for sensitive detector operation. Vendors shall provide guaranteed ripple and noise specifications with measurement conditions.
- Ethernet-based remote monitoring and control are required, including readback of voltage, current, status, fault state, and temperature or over-temperature status.
- A local service/configuration interface is required. Web interface and SNMP support are specifically required for SLAC controls integration.
- The system shall be air-cooled, protected against over-temperature conditions, and suitable for continuous operation at rated load in the intended SLAC installation environment.
- Operate from SLAC-compatible AC mains power, nominally 100–240 VAC, 50/60 Hz, with appropriate power factor correction and compliance with applicable electrical safety and EMC standards.
- The system shall be compatible with standard SLAC rack or detector support installations. Standard 19-inch rack mounting is required if installed in existing SLAC racks.
- A compact form factor, such as 3U height or less and approximately 450 mm depth or less, is preferred unless the final installation envelope requires these limits.
- Vendors shall provide mechanical dimensions, weight, cooling requirements, power input requirements, output connector details, isolation ratings, safety certifications, and remote-control interface documentation.
- Redundant output capability, master-slave or parallel operation for current boosting, extended floating voltage capability, browser-based configuration, SNMP support, and modular field-serviceable architecture are required by the detector configuration.
Source Selection:
Source selection will be conducted using the Lowest Price Technically Acceptable (LPTA) method.
Award will be made to the responsible Offeror submitting the lowest-priced offer that is determined technically acceptable in accordance with the stated evaluation factors.
Please provide a price and lead time quotation by Monday, November 30, 2026.
Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?
Buy American Act Certification (BAA) applies as applicable to this procurement.
Representations & Certifications Rider is required. Once completed, the Reps and Certs is valid for one year until renewal. If you have already completed one within the year, please disregard. Otherwise, please complete and return.
Please include in your proposal the Harmonized Tariff Schedule (HTS Code) and Export Control Classification Number (ECCN), if applicable.
Please identify any applicable tariffs, duties, or other import-related charges as separate line items in your quotation.
All subcontractors are required to register in the System for Award Management (SAM.gov).
If possible, please provide a link to your webpage for a published price list or other information to substantiate the prices quoted.
The resulting purchase order will be issued on a fixed-price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services, as well as any applicable supplemental rider, will be made a part of the resulting order. Please markup the terms and conditions if you wish to negotiate. No markups mean that you accept SLAC Terms and Conditions.
Payment Terms will be NET-30.
Domestic Suppliers: Freight terms will be FOB Destination Prepaid and Add.
Foreign Suppliers: Shipment will be made CIP SLAC, Menlo Park, and Duty Unpaid.
You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.
Please submit your quotation by Monday, November 30, 2026.
Contact me directly with any questions.
Ashli Gibson | Procurement Commodities Team
BSD Supply Chain Management
P: 650-926-3167
E: ashlig@slac.stanford.edu
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Files (4)
- Download
SLAC General Terms and Conditions Supplemental Rider Rev August 2026.pdf
750 KBAdded in Solicitation version 2Posted - Download
Fixed_Price_Commercial_Supplies_and_Services_Subcontract_Aug2023.pdf
325 KBAdded in Solicitation version 2Posted - Download
Reps and certs Rider - September 2022.pdf
983 KBAdded in Solicitation version 2Posted - Download
01. BAA_Certification_08.29.2023_(D5) (1).pdf
570 KBAdded in Solicitation version 2Posted
Lifecycle
- 1
- 2
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
SLAC_369019_DCPowerSupply
Archive Date
Dec 15, 2026
Office Address
Menlo Park, CA, 94025