RPC Power Factor Correction Work Package 1 - Demolition

Archived on July 24, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM PDT
Posted
July 17, 2026
Notice type
Sources Sought
Set-aside
No Set aside used
Agency
Department of Energy

Notice details

Office
SLAC Natl Accel Lab -DOE Contractor
Place of performance
Menlo Park, California, 94025
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
SLAC_RFP_367094
Notice ID
99bbf7310e21477c91b960e33506e947

Description

Introduction and Overview:

The subcontractor must provide all labor, oversight, tools, materials, equipment, and services necessary to complete the work safely and in compliance with approved BIO documents as well as SLAC, DOE, and ES&H standards. SLAC receives power at its Master Substation (MSS) from a PG&E 230kV transmission line via two 230kV/12.47kV stepdown transformers. SLAC identifies that its AC power system encounters power factor issues at the point of connection (POC) with PG&E, where the power factor strays outside the contractual range (0.97 lag to 0.99 lead). This deviation stems from various factors, including reactive power imbalances, capacitive or inductive loads, etc. Consequently, suboptimal power factor conditions can result in increased power losses, reduced system efficiency, and involve potential penalties imposed by PG&E. To address this challenge, SLAC plans to implement power factor correction measures through the installation of two switched power factor correction (PFC) systems – one on 12.47 kV Bus-1 and another on 12.47kV Bus-2 at the Master Substation (MSS). These PFC units will dynamically improve reactive power flow, compensating for system reactive power demand, and maintaining the overall power factor within the required range. Enhancing power factor correction in this manner will optimize energy utilization, reduce system losses, and ensure continued compliance with PG&E contractual requirements.

Purpose:
Prior to the installation of the new power factor correction equipment, it is necessary to demolish existing buildings (B308 and B311) with equipment inside them to create adequate space within the MSS Yard. This Statement of Work outlines the scope for the demolition, disassembly, and removal of existing assets, including metal buildings B308 and B311, a non-operational synchronous condenser, and the associated electrical equipment and cabling and wiring serving the condenser. All identified buildings and equipment are located in the SLAC MSS Yard.

THIS IS FOR SOURCES SOUGHT ONLY, DO NOT SUMBIT BIDS. While the draft RFP package has been included with this post, the RFP has not been released. Interested vendors should express their interest by sending their capabilities statement to Doreen Agbayani at doreena@slac.stanford.edu.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Documents

Files (25)

  • B2_07.1_DBA_WD_CA20260018_7.14.26_Mod_06_DRAFT.pdf

    3.7 MBAdded in Sources Sought version 3Posted
    Download
  • B2_05.1_Fixed_Price_Construction_March2024_DRAFT.pdf

    1.3 MBAdded in Sources Sought version 3Posted
    Download
  • B2_09.2_Section_L_Attachment_B_SLAC_Question&Answer_Log_(RFI)_DRAFT.pdf

    754 KBAdded in Sources Sought version 3Posted
    Download
  • B2_07.4_SF1413_DRAFT.pdf

    699 KBAdded in Sources Sought version 3Posted
    Download
  • B2_07.3_Work_Classification_Form_367094_DRAFT.pdf

    649 KBAdded in Sources Sought version 3Posted
    Download
  • B2_04_Section_F_(Deliveries_Performance)_DRAFT.pdf

    641 KBAdded in Sources Sought version 3Posted
    Download
  • B2_07.6_NTP_Submittal_Checklist_061424_DRAFT.pdf

    582 KBAdded in Sources Sought version 3Posted
    Download
  • B2_09.0_Section_L_Instruction_to_Offerors_DRAFT.pdf

    322 KBAdded in Sources Sought version 3Posted
    Download
  • B2_07.5_SubcontractorFormSQF_DRAFT.pdf

    322 KBAdded in Sources Sought version 3Posted
    Download
  • B2_10_Section_M_Evaluation_Methodology_DRAFT.pdf

    241 KBAdded in Sources Sought version 3Posted
    Download
  • B2_05.0_Section_G_(General_TsCs)_DRAFT.pdf

    235 KBAdded in Sources Sought version 3Posted
    Download
  • B2_07.2_Subcontractor_Form_IIPP_052121_DRAFT.pdf

    228 KBAdded in Sources Sought version 3Posted
    Download
  • B2_07.8_Construction_Subcontracts_Final_Release_DRAFT.pdf

    186 KBAdded in Sources Sought version 3Posted
    Download
  • B2_07.0_Section_J_(List_of_Attachments)_DRAFT.pdf

    170 KBAdded in Sources Sought version 3Posted
    Download
  • B2_06_Section_H_(Special TsCs)_DRAFT.pdf

    185 KBAdded in Sources Sought version 3Posted
    Download
  • B2_08.0_Section_K_(Rep_and_Certs)_DRAFT.pdf

    163 KBAdded in Sources Sought version 3Posted
    Download
  • B2_07.7_Final_Inspection_Report_DRAFT.pdf

    123 KBAdded in Sources Sought version 3Posted
    Download
  • B2_09.1_Section_L_Attachment_A_Proposal_Breakdown_Sheet_DRAFT.pdf

    122 KBAdded in Sources Sought version 3Posted
    Download
  • B2_08.1_Reps_and_Certs_Supplement_DRAFT.pdf

    65 KBAdded in Sources Sought version 3Posted
    Download
  • B2_01_Section_A_(Subcontract_Form)_DRAFT.pdf

    634 KBAdded in Sources Sought version 3Posted
    Download
  • B2_02_Section_B_(Supplies_or_Services_and_Price_Costs)_DRAFT.pdf

    631 KBAdded in Sources Sought version 3Posted
    Download
  • B2_00_RFP_Cover_DRAFT.pdf

    622 KBAdded in Sources Sought version 3Posted
    Download
  • B2_03.0_Section_C_(Specifications_SOW)_DRAFT.pdf

    586 KBAdded in Sources Sought version 3Posted
    Download
  • B2_03.3_SLAC BIO Adopted Codes and Standards (Updated 01012025)_DRAFT.pdf

    466 KBAdded in Sources Sought version 3Posted
    Download
  • B2_03.1_SOW_RPC WP1 Demolition_R3_DRAFT.pdf

    386 KBAdded in Sources Sought version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    RPC Power Factor Correction Work Package 1 - Demolition

    Notice 99bbf7310e21477c91b960e33506e947 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

SLAC_RFP_367094

Archive Date

Jul 24, 2026

Office Address

Menlo Park, CA, 94025