Notice ID: 9a99b38488df4a31a78b196b7e16f0a8Combined Synopsis/Solicitation
Electric Power Resiliency Building 56
Active, responses due . Full description on SAM.gov.
Overview
- Response deadline
- 1:00 PM EST
- Posted
- November 12, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Small Business Set Aside - Total
- NAICS
- 238210: Electrical Contractors and Other Wiring Installation Contractors
- Agency
- Department of WarDEFENSE LOGISTICS AGENCY
Notice details
- Office
- DLA DISTRIBUTION.DLA DISTRIBUTION
- Place of performance
- Tracy CA, 95304
- PSC
- Z2GZ: REPAIR OR ALTERATION OF OTHER WAREHOUSE BUILDINGS
- Last updated
- Nov 12, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- SP330027Q0012
- Notice ID
- 9a99b38488df4a31a78b196b7e16f0a8
Description
Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.
Award Overview
No prior contract identified
No matching prior contract was found within an 18-month window using the same agency, NAICS, place-of-performance state, and PSC. This may be a new requirement, or the prior award uses a different classification.
Contacts
Contracting Officer
Primary Contact
Documents
Links (4)
- PIEE Solicitation Module Link for SP330027Q0012piee.eb.milPosted
- Web Based Training for the PIEE Solicitation Modulepieetraining.eb.milPosted
- Registration Instructions for the PIEE Solicitation Modulewww.acq.osd.milPosted
- Department of Defense Procurement Toolboxtoolbox-piee.eb.milPosted
Lifecycle
- 1Version 1Combined Synopsis/Solicitation
Electric Power Resiliency Building 56
- 2Version 2Combined Synopsis/SolicitationCurrent
Electric Power Resiliency Building 56
Similar Opportunities
Title | Phase | Deadline |
|---|---|---|
Additional Details
Solicitation Number
SP330027Q0012
Archive Date
Mar 31, 2027
Office Address
NEW CUMBERLAND, PA, 17070-5002