Fire Suppression Monitoring and Pump Inspections
Archived on December 17, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 3:00 PM MST
- Posted
- November 26, 2025
- Notice type
- Sources Sought
- NAICS
- 561210: Facilities Support Services
- Agency
- Department of Health and Human ServicesINDIAN HEALTH SERVICE
Notice details
- Office
- BILLINGS AREA INDIAN HEALTH SVC
- Place of performance
- Crow Agency, Montana, 59022
- Last updated
- Nov 5, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- SS-IHS1520475-BI
- Notice ID
- 470d760780ae40eb954d10e5c7a244a0
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY; IT IS NOT A REQUEST FOR QUOTE, RATHER MARKET RESEARCH TO DETERMINE COMPLAINCE WITH THE BUY INDIAN ACT AND DETERMINATION OF SET-ASIDE.
The Billings Area Indian Health Service (BAIHS) is seeking to identify Indian Small Business Economic Enterprise (ISBEE) or Indian Economic Enterprises (IEE) sources pursuant to the Buy Indian Act (25 U.S.C. 47), capable of performing the Indian Health Services (IHS) requirement for Fire Suppression Monitoring and Pump Inspections located at the Crow Service Unit, Lodge Grass Clinic and Pryor Health Clinic. Any vendor responding to this notice should submit their capability statement as well as the Buy Indian Act Indian Economic Enterprise Representation Form (attached).
This notice is issued solely for information and planning purposes; it does not constitute a Request for Quotation (RFQ), or a promise to issue an RFQ in the future. This notice does not commit the U.S. Government to contract for any supply or service. Further, the Government is not seeking quotes, or proposals at this time.
INSTRUCTIONS TO INDUSTRY
ISBEEs are highly encouraged to respond to this notice. However, firms must also understand that generic capability statements are not sufficient for effective evaluation of their capacity and capability to perform the work required. To be considered a capable source, responses must directly demonstrate the company’s capability, experience, and ability to provide services as described in the attached statement of work.
Responses which do not provide the requested information specified in this sources sought notice will be considered non-responsive.
SUBMISSION
Interested parties capable of performing the required services may submit a response via email to: katrina.eaglefeathers@ihs.gov. To be considered, your response must be received no later than the time & date established for the response date on this sources sought announcement.
Interested parties shall submit their capability response as instructed above and include a copy of the Buy Indian Act Indian Economic Enterprise Representation Form. It is recommended to include the sources sought ID in the subject line: SS-IHS1520475-BI. Responses received to this notice will assist in determining the acquisition strategy of the requirement.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Lifecycle
- 3Version 3Sources SoughtArchivedCurrent
Fire Suppression Monitoring and Pump Inspections
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
The requirement consists of inspection and repair services for existing wet-pipe fire sprinkler systems located in Buildings N-104 and T-1002. Required tasks include National Fire Protection Association (NFPA) Standard 25 five-year internal obstruction investigations, sprinkler head surveys, removal and submission of sprinkler heads for Underwriters Laboratories (UL) testing, and the repair or replacement of valves, gauges, pipe sections, hangers, water motor alarms, and related fire protection system components. All work must comply with NFPA 25 (Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems), NFPA 13 (Installation of Sprinkler Systems), NFPA 72 (National Fire Alarm and Signaling Code), NFPA 101 (Life Safety Code), applicable International Code Council (ICC) building codes, and Occupational Safety and Health Administration (OSHA) regulations. The complete description of required tasks is contained in the Government?s Performance Work Statement (PWS).The applicable North American Industry Classification System (NAICS) code is 561210 ? Facilities Support Services, with the corresponding Product Service Code (PSC) H312 ? Inspection and Repair of Fire Control Equipment. | 76% | Combined Synopsis | 12/19/2025 |
Fire Alarm Testing and Maintenance Amendment | 70% | Combined Synopsis | 09/14/2026 |
The U.S. Army Corps of Engineers, Southwestern Division (SWD), Tulsa District (SWT) issued a commercial solicitation, W912BV26QA064, for the ROBERT S. KERR MARINE TERMINAL - INSPECTION AND CERTIFICATION OF FIRE SUPPRESSION SYSTEM. | 58% | Combined Synopsis | 05/22/2026 |
56% | Awarded | Open | |
PURPOSE: The purpose of the sources sought is to identify available authorized businesses to provide Fall Arrest System Inspection Services. This sources sought notice is for informational and planning purposes only. Pricing information is not being requested at this time. It does not constitute a solicitation and is not to be considered as a commitment by the Government. REQUIREMENT: This notice is issued by the U.S. Air Force, 92d Contracting Squadron, Fairchild AFB, WA. This sources sought is seeking to identify responsible potential sources to provide Fall Arrest System Inspection Services. The inspections must be in accordance with the draft Statement of Work. ANTICIPATED NAICS/SIZE STANDARD: This requirement falls under the NAICS Code of 561210 - Facilities Support Services, with a size standard of $47 Million. SUBMISSION OF INFORMATION: All firms responding to this sources sought notice are advised that their response to this notice is not a request that will be considered for contract award. All interested parties will be required to respond to the resultant solicitation separately from their response to this sources sought notice. A responsible potential source shall have registered with the System for Award Management (SAM). The response should be no more than five pages providing the following information: Business name, address, CAGE code/UEI Size and socioeconomic classification based on NAICS size standard If claiming a specific small business category, provide supporting documentation Point of contact including email and phone number | 54% | Market Research | 11/26/2026 |
Additional Details
Solicitation Number
SS-IHS1520475-BI
Archive Date
Dec 17, 2025
Office Address