GovChime
Notice ID: 82e14b4bce45d6d476b51a67c4baf1b6Presolicitation

99--RTS WRIGHT INDUSTRIES LLC 15229 Woodcrest Drive Clive, IA 50325

Archived on December 29, 2008. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 AM UTC−05:00
Posted
November 25, 2008
Notice type
Presolicitation
NAICS
541990: All Other Professional, Scientific, and Technical Services

Notice details

Place of performance
VA Boston Healthcare System;940 Belmont Street;Brockton;MA 02301 USA
PSC
99: MISCELLANEOUS
Last updated
Sep 25, 2026

Identifiers

Solicitation number
VA-241-09-RQ-0072
Notice ID
82e14b4bce45d6d476b51a67c4baf1b6

Description

The Department of Veterans, VA Boston Healthcare System, has a requirement for vendor, RTS Wright Industries LLC, located in 15229 Woodcrest Drive, Clive, IA 50325 to provide the RTS Blood Fractionation System for MAVERIC, in Jamaica Plain campus, 150 South Huntington Ave., Boston, MA 02130. It is the Government's intention to solicit and negotiate only with this source. Please refer to the Sole Source Justification. This is not a solicitation; it is notice of intent to sole source a requirement. Also this notice of intent is not a request for competitive quotes. No solicitation document is available and telephone requests will not be accepted. However, any firm that believes it can meet these requirements may give written notification to the Contracting Officer within five (5) calendar days from the date of publication of this synopsis. Supporting evidence must be furnished in sufficient detail, to demonstrate the ability to comply with the above requirements. This information can be faxed to Christine Gorman at 774-826-3347. Responses will be evaluated; however, a determination by the Government not to compete the proposed procurement based upon responses to this notice is solely within the discretion of the Government. Inquires/information received after established deadline of Friday, November 29, 2008 16:00 EST shall not be considered. The submission of any data for review shall not impede award of this contract as planned. The Government does not intend to pay for information solicited. This synopsis is issued pursuant to FAR 6.302-1. Post in FBO today for 5 days i.e. 11/24/2008 16:00 pm ESTDeadline 11/29/2008 16:00 pm EST Contract Specialist: Christine Gorman, e-mail: Christine.Gorman@va.gov JUSTIFICATION FOR OTHER THAN FULL AND OPEN COMPETITION: 1. Transaction # or Purchase order #: 523-09-1-9183-0037 2. Identification of the agency and the contracting activity: VA Medical Center, Research - MAVERIC, Boston, MA 3. Nature and/or description of the action being approved: Sole Source Procurement for Supplies/Services 4. Description of the supplies or services required to meet the agency's needs (including the estimated value): RTS Blood Fractionation SystemVendor: RTS Wright Industries US Patent application 2006/0077376Price: $750,890 The Massachusetts Veterans Epidemiology Research and Information Center (MAVERIC) Core Laboratory processes and stores specimens for clinical trails run by the VA Cooperative Studies Program. The laboratory has over a half million vials of specimens in 18 REVCO freezers and 19 MVE liquid nitrogen tanks. Central Office is ramping up the ability of the laboratory to process specimens and has asked us to purchase an automated system for processing blood samples. The automated system must be able to identify and separate the three components of blood (plasma, buffy coat, red cells) that are present after centrifuging blood specimens. An automated system can process many more samples per day than a laboratory technician can and likely in a more precise manner. Adding more technicians is expensive and requires the purchase of additional expensive safety engineering controls such as biological safety cabinets. In addition, the laboratory does not have room to add this equipment and there is little, if any, additional space available in the research building. MAVERIC has already purchased one automated system from RTS, in order to provide a backup system; a duplicate of the automated system must be purchased. Technical specifications of the two systems are identical and all components interchangeable. 5. Identification of the statutory authority permitting other than full and open competition: FAR 6.302-1, USC 253(c)(1) Only One Responsible Source. 6. Demonstration that the proposed contractor's unique qualifications or the nature of the acquisition requires use of the authority cited: RTS developed and has placed in service high throughput blood fractionation systems for both the UK Biobank and the HUNT Biobank in Norway. These systems are being used to separate blood into plasma, buff coats, and red cell aliquots for storage. RTS developed this system and has patents pending on the process which may explain the lack of similar systems by other vendors. There are many systems on the market that can remove the top plasma layer. These are widely used in clinical laboratories throughout the country. However, these systems simply remove an aliquot of plasma from the top of the blood tube. None of these systems can identify the buffy coat region that sits under the plasma layer and on top of the red cells. This buffy coat is the most important component for the research laboratories because this is the component that contains the white cells and DNA. It is critical that this component be separately stored. 7. Description of efforts made to ensure that offers are solicited from as many potential sources as is practicable, including whether a Commerce Business Daily notice was or will be publicized as required by Subpart 5.2 (copy attached) and, if not, which exception under 5.202 applies: MAVERIC has already purchased (in FY 07) one automated blood fractionation system (set for delivery in 10/08). Since the original purchase we recognized the need for a backup system in the event of breakdown or servicing of the 1st system. In order to provide redundant capabilities, a second system must be purchased. Addition of the second machine should provide continuous service of at least one machine in the lab at all times and guarantee that the lab is able to process the hundreds of blood specimens that will arrive from VA Hospitals each day.There is still no other commercially available machine that can perform the function of the RTS ABF500 machine (distinguish the three components of blood in a blood tube and separately aliquot the fractions). Even if a another machine was available, robotic machines from two different vendors are not going to have the same exact specifications as the RTS automated fractionation system is patented. This would mean parts are not interchangeable and a second system would not guarantee continuous operations in the laboratory. 8. Determination by the contracting officer that the anticipated cost to the government will be fair and reasonable: The cost to the Government will be determined to be fair and reasonable in accordance with criteria stipulated in FAR 15 and Historical data. 9. Description of the market survey conducted (i.e., names of firms and the date(s) the firms were contacted) and the results, or a statement of the reasons a market survey was not conducted: None today. 10. Any other facts supporting the use of other than full and open competition, such as an explanation why technical data packages, specifications, engineering descriptions, statements of work, or purchase descriptions suitable for full and open competition have not been developed or are not available: None to date. 11. A listing of the sources, if any, that expressed, in writing, an interest in the acquisition: None to date. 12. A statement of the actions, if any, the agency may take to remove or overcome any barriers to competition before any subsequent acquisition for the supplies or services required: Contracting Activity will continue to encourage full and open competition whenever possible. STATEMENT OF WORK ADDENDUM TO BLOCK 19 ON SF-1449 SUPPLIES OR SERVICES AND PRICES/COST SUMMARY: Furnish one (1) Automated Blood Fractionation System (ABF500) Quantity Unit Unit Cost Amount Automated Blood Fractionation System 1 EA Refrigeration 1 EA TRANSPORTATION 1 EA Delivery and Installation 1 SV Extended Warranty 1 SV (Gold Support) _________ Grand total: $ ========= SECTION C - DESCRIPTION / SPECIFICATION ITEM 1. Automated Blood Fractionation System is a robotic processing system for fractionating whole blood. This unit will be identical to the machine currently under order and will be installed in the MAVERIC Core Laboratory (RB-8). On addition of centrifuged blood tubes, the system will read the bar-coded identifier on the tube and determine the locations of the blood fractions (plasma, buffy coat, red cells) within the tube. The robotic system will automatically remove user-specified volumes of each fraction and separately aliquot into a user-specified number of bar-coded cryovials. The system will track sample identifiers, specimen type, cryovial identifier, and sample location (rack ID and location within rack), and maintain a complete audit trail. The system specifications are identical to the ABF500 currently under order (ref: VA-241-P-0225) and covers the following stipulations as detailed in that document (except paragraph h which has been modified to suit delivery of this second instrument): a) The system design must have the flexibility to work with cryovials and vacutainers of our specification. The cryovials must be compatible with an automated capper/decapper system. b) The system must operate in a continuous mode, ie the user will be able to load single racks of centrifuged vacutainers part way through the run. c) Automatically read bar codes of tubes and racks at each stage so that a complete audit trail is maintained. This should include tracking the ID of each sample processed as well as the location of each aliquot within the sample output racks (ie rack ID and position). d) The system must have the ability to cope with a wide range of blood samples, including differences in the volume of blood in each tube and also the consistency of each blood fraction. e) The system must have the ability to separate the three components of centrifuged blood,including plasma, buffy coat, and red cells. Once these three levels have been identified they must be automatically transferred to separate cryovials. f) The system must include an 8 tip pipettor with liquid level detection, a camera based vision system to detect fractions, and controlling software. g) The system must be able to process at a minimum 500 samples per day. h) Delivery date to be confirmed but will be on or before September 30, 2009. i. The purchase price includes a one year warranty that includes all machine parts, software, and service to maintain normal operation of the automated blood fractionation system. j) The system will be installed in R8-8 (Research Laboratory), of the Boston VAHCS, Jamaica Plain campus. The primary point of contact in coordinating the installation of the equipment isDonald Humphries, PhD, Scientific Director, MAVERIC Laboratory.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Christine Gorman Contract Specialist

Documents

No documents available.

Lifecycle

Solicitation:VA-241-09-RQ-0072
  1. Pre-Solicitation

Formal solicitation typically follows within 30–60 days. (estimate)

  1. Pre-SolicitationCurrentNov 25, 2008

    99--RTS WRIGHT INDUSTRIES LLC 15229 Woodcrest Drive Clive, IA 50325

    Notice 82e14b4bce45d6d476b51a67c4baf1b6 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

VA-241-09-RQ-0072

Archive Date

Dec 29, 2008