Notice ID: e87f885e6a6142d2b88024a9480b8346Combined Synopsis/Solicitation
Mobile Ground Power Unit
Archived on August 31, 2024. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM UTC−04:00
- Posted
- August 7, 2024
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Small Business Set Aside - Total
- NAICS
- 335311: Power, Distribution, and Specialty Transformer Manufacturing
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- W7NR USPFO ACTIVITY NYANG 105
- Place of performance
- Newburgh, 12550
- Last updated
- Sep 25, 2026
Identifiers
- Solicitation number
- W50S8D24Q10X1
- Notice ID
- e87f885e6a6142d2b88024a9480b8346
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. Solicitation W50S8D24Q10X1 is being issued as a Request for Quote (RFQ). Incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-05. This acquisition is being solicited as a total small business set-aside. The North American Industry Classification System (NAICS) code is 335311 with a small business size standard of 800 employees. Only one (1) award will be made as a result of this combined synopsis/solicitation. The 105th Airlift Wing is seeking the following items on a brand name or equal basis. CLIN 0001 Unitron Part # UFC-20M-420UDC, 20-kVA AC/DC PwrKart mobile combination frequency converter / ground power system. CLIN 0002 Part # WIH-20, Input cable, 20 feet, single jacket 3-conductor with ground and plug ready. CLIN 0003 Part # WOA-30M, AC output cable, 30 feet, banded multiple conductor with aircraft plug. CLIN 0004 Part # WOD-30M – DC output cable, 30 feet, banded multiple conductor with aircraft plug. The Government will award a contract resulting from this solicitation to the responsible offeror whose quote conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: (i) Price (ii) Technical Capability Evaluation of price will be performed using one or more of the price analysis techniques in FAR 13.106-3. Through these techniques the Government will determine whether the price is reasonable, complete and not unbalanced. Quotes must include cutsheet product information on the proposed equipment to allow the government to determine technical merit. This may include descriptive product literature, technical information, spec sheets, etc., which clearly indicates the products offered meet the Government's minimum requirements. Failure to provide this information will render the quote non-responsive and will be removed from further award consideration. Award will be made to the lowest priced quote that provides sufficient explanation/documentation to demonstrate their ability to conform to the requirements of the Statement of Work. Quotes are due no later than 2:00 PM EST, 16 August 2024. If there are any questions regarding this requirement, please contact Mr. Joseph Kugler by email: joseph.kugler.1@us.af.mil. All interested offerors must be registered in the System for Award Management (SAM) before an award can be made. To register with SAM, log on to https://www.sam.gov. The following provisions/clauses are applicable to this procurement: FAR 52.203-18 Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements-Representation; FAR 52.203-19 Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements; FAR 52.204-7 System for Award Management; FAR 52.204-16 Commercial and Government Entity Code Reporting; 52.204-22 Alternative Line Item Proposal; FAR 52.204-23 Prohibition on Contracting for Hardware, Software, and Services Developed or Provided by Kaspersky Lab and Other Covered Entities; FAR 52.204-24 Representation Regarding Certain Telecommunications and Video Surveillance Services or Equipment; 52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment; FAR 52.204-26 Covered Telecommunications Equipment or Services- Representation; FAR 52.211-6 Brand Name or Equal; FAR 52.212-1 Instructions to Offerors; FAR 52.212-4 Contract Terms and Conditions; FAR 52.212-5 Contract Terms and Conditions Required To Implement Statutes Or Executive Orders; FAR 52.219-6 Notice of Total Small Business Set-Aside; FAR 52.222-21 Prohibition of Segregated Facilities; FAR 52.222-26 Equal Opportunity; FAR 52.222-41 Service Contract Labor Standards; 52.222-50 Combating Trafficking in Persons; FAR 52.222-55 Minimum Wages for Contractor Workers Under Executive Order 14026; FAR 52.225-13 Restrictions on Certain Foreign Purchases; FAR 52.232-33 Payment by Electronic Funds Transfer-System for Award Management; FAR 52.232-40 Providing Accelerated Payments to Small Business Subcontractors; FAR 52.233-3 Protest After Award; FAR 52.233-4 Applicable Law for Breach of Contract Claim; FAR 52.237-1 Site Visit; FAR 52.252-2 Clauses incorporated by reference; DFARS 252.203-7000 Requirements Relating to Compensation of Former DoD Officials; DFARS 252.203-7005 Representation Relating to Compensation of Former DoD Officials; DFARS 252.204-7003 Control of Government Personnel Work Product; DFARS 252.204-7011 Alternative Line Item Structure; 252.204-7012 Safeguarding Covered Defense Information and Cyber Incident Reporting (DEVIATION 2024-O0013); DFARS 252.204-7015 Notice of Authorized Disclosure of Information for Litigation Support; DFARS 252.204-7016 Covered Defense Telecommunications Equipment or Services-Representation; DFARS 252.204-7017 Prohibition on the Acquisition of Covered Defense Telecommunications Equipment or Services-Representation; DFARS 252.204-7018 Prohibition on the Acquisition of Covered Defense Telecommunications Equipment or Services; 252.204-7024 Notice on the Use of the Supplier Performance Risk System; DFARS 252.225-7031 Secondary Arab Boycott of Israel; DFARS 252.225-7059 Prohibition on Certain Procurements from the Xinjiang Uyghur Autonomous Region–Representation; DFARS 252.225-7060 Prohibition on Certain Procurements from the Xinjiang Uyghur Autonomous Region; DFARS 252.232-7003 Electronic Submission of Payment Requests; DFARS 252.232-7010 Levies on Contract Payments; DFARS 252.244-7000 Subcontracts for Commercial Items; Full text clauses may be accessed electronically at https://www.acquisition.gov/. 52.252-6 AUTHORIZED DEVIATIONS IN CLAUSES (APR 1984) (a) The use in this solicitation or contract of any Federal Acquisition Regulation (48 CFR Chapter 1) clause with an authorized deviation is indicated by the addition of "(DEVIATION)" after the date of the clause. (b) The use in this solicitation or contract of any Defense Federal Acquisition Regulation Supplement (48 CFR Chapter 2) clause with an authorized deviation is indicated by the addition of "(DEVIATION)" after the name of the regulation.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
No documents available.
Lifecycle
Solicitation:
W50S8D24Q10X1- Combined Synopsis
- 2×Combined SynopsisCurrentAug 4, 2024
Mobile Ground Power Unit
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Fuseholder | - | Combined Synopsis | 10/06/2026 |
1000 KVA TRANSFORMER | - | Combined Synopsis | 09/30/2026 |
Pad Mount Transformer | - | Combined Synopsis | 08/31/2026 |
Provide one Pad Mounted Transformer 750 kVA, 13.2 kV /208Y/120 V. Salient Characteristics: Furnish one (1) pad mounted, dead front, radial transformer, rated: ? Capacity: 750 kVA ? Phases: 3 ? Primary Voltage: 13,200 V (15 kV class) ?Secondary Voltage: 208Y/120 V ? Frequency: 60 Hz ? Phase: Three phase ? Cooling :ONAN ? Fluid: Mineral oil 2. Mandatory Physical Dimensions: The following dimensions are non negotiable: ? Height: 63? inches (up to 64? inches) ? Width: 65 inches ? Depth: May varies (existing is 41 inches) The Contractor shall confirm with proposal the manufacturing dimensions, either in writing or by a shop drawing, for government approval. 3. Mechanical and Construction Requirements: The transformer shall include: ?Stainless steel tank, cabinet and hardware (304) ? Dead front construction ? Pentahead security hardware ? ANSI 61 Grey color to match with existing enclosure ? Welded tank construction, sealed and pressure tested ? 1-inch Oil drain valve located on the primary side with 3/8-inch water sampler (required due to secondary side cable congestion) ? Arc-flash and safety labeling ? Lifting lugs and jacking pads ? Nameplate per ANSI C57.12.00 4.Electrical Requirements: ? Primary bushings: (6) 200 A load break wells with inserts for (3)LV and (3) 10KV arresters ? Secondary bushings: NEMA spade w/ supports terminals 10holes (3) LV and (1) neutral per ANSI ? Configuration: Radial Feed ? Impedance: Standard ANSI values for 750 kVA ? Taps: 2 x 2.5% (standard 5 position no load tap changer) 5.Protection and Monitoring: The transformer shall include: ? Bayonet fuse with isolation link? Current limiting fuses ? Load break switch (2 position minimum) ? Nitrogen pressure gauge, test port and blanket ? Temperature gauge ? Pressure vacuum gauge ? Liquid level indicator ? Schrader valve Note: All gauges must be visible. 6. Compliance Requirements: The transformer must comply with: ? ANSI/IEEE C57.12 series ? DOE 2016 efficiency standards ? National Electrical Safety Code (NESC) ? National Electrical Code (NEC /NFPA 70) ? UFGS 26 12 19 ? Pad Mounted, Liquid Filled, Medium Voltage Transformers ?American Buy Act ? PCB-free oil certification ? UL Listed 002. Provide Factory routine test Reports Results and documentation as minimum: ? Insulation resistance test ? Winding resistance test ? Turns ratio (TTR) ?Polarity and phase-relation test ? No-load and load-loss test ? Dielectric test ? Excitation test ?Impedance test ? Applied and Induced potential tests ? Leak Test ? Oil quality test (dielectric strength, moisture, interfacial tension) ? Certified As-built drawings ? Certified test report signed by manufacturer ? Installation and OM manuals ? Warranty documentation (minimum 1 year) ? Destination to the federal facility Fort Buchanan, Puerto Rico00934 ? ECD: 40 weeks ? Unit must arrive fully assembled and ready for installation ?Packing slip must include contract number, PO number, and serial number? Minimum 1 year manufacturer warranty covering defects in equipment. | - | Combined Synopsis | 07/29/2026 |
1600 A automatic transfer switch | - | Combined Synopsis | 06/17/2026 |
Additional Details
Solicitation Number
W50S8D24Q10X1
Archive Date
Aug 31, 2024
Office Address