Building 1 HVAC Repair
Archived on March 28, 2026. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM EDT
- Posted
- March 5, 2026
- Notice type
- Solicitation
- Set-aside
- No Set aside used
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- NATIONAL GUARD BUREAU.JFHQ USPFO OH.USPFO OH PROCUREMENT.W7NU USPFO ACTIVITY OHANG 178
- Place of performance
- Blue Ash, Ohio, 45242
- PSC
- Z2NZ: REPAIR OR ALTERATION OF OTHER UTILITIES
- Last updated
- Nov 3, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- W50S8Q26QA001
- Notice ID
- f913615fff8f4152aa8b1b40a006cc0a
Description
PROJECT TITLE: Bldg 1 HVAC Repair
PROJECT LOCATION: Blue Ash ANGB
NAICS CODE: 238220
SIZE STANDARD: $19,000,000.00
FULL AND OPEN COMPETITION
DISCLOSURE OF MAGNITUDE: IAW FAR 36.204(c) Is Between $100,00 and $250,000.
EMAIL ALL PROPOSALS TO: kurt.becka@us.af.mil & seth.taylor.8@us.af.mil
DAVIS BACON WAGE RATES ARE APPLICABLE TO THIS PROJECT. PREVAILING WAGE DERTERMINATION WILL BE INCUDED AT TIME OF AWARD.
BID BOND REQUIRED.
SEE SITE VISIT INFORMATION UNDER FAR 52.236-27
The intent of this project is to repair the HVAC at BLDG 1 Blue Ash Air National Guard Base. The following actions must be taken to meet this intent: remove and dispose of the existing 30-ton RTU. Provide and install a new RTU; install new curbing only if required to fit the new unit. Remove the existing DDC controller and install new. Install new controls onto all HVAC components that are currently on the DDC. Provide and configure a new computer and workstation for the DDC. Remove the existing roof access ladder and hatch handrail and install new.
Award Overview
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Files (15)
- Download
W50S8Q26QA001_Solicitation RFIs_B1 HVAC.pdf
65 KBAdded in Solicitation version 6Posted - Download
Solicitation Amendment - W50S8Q26QA0010002 Professional Appearance.pdf
6.3 MBAdded in Solicitation version 4Posted - Download
Solicitation Amendment W50S8Q26QA0010002 SF 30.pdf
3.8 MBAdded in Solicitation version 4Posted - Download
SOW BVGM252001-FY26-Revised1.pdf
224 KBAdded in Solicitation version 4Posted - Download
B1 Roof Plans.pdf
3.4 MBAdded in Solicitation version 3Posted - Download
Thermostat Photo.jpeg
86 KBAdded in Solicitation version 3Posted - Download
VAV Photo.JPG
422 KBAdded in Solicitation version 3Posted - Download
Final-Solicitation Amendment-W50S8Q26QA0010001-Professional Appearance.pdf
6.3 MBAdded in Solicitation version 2Posted - Download
VAV Controller Photo.JPG
241 KBAdded in Solicitation version 3Posted - Download
Final-Solicitation Amendment-W50S8Q26QA0010001-SF 30.pdf
3.8 MBAdded in Solicitation version 2Posted - Download
B1 HVAC_Site Visit Sign-In.pdf
546 KBAdded in Solicitation version 3Posted - Download
Binder_BLDG 1 HVAC Drawings.pdf
7.7 MBAdded in Solicitation version 1Posted - Download
Springfield Base Facility Standards - FINAL - March 2025 Signed.pdf
693 KBAdded in Solicitation version 1Posted - Download
Material Submittals BVGM252001.xlsx
24 KBAdded in Solicitation version 1Posted - Download
RFI Template.docx
14 KBAdded in Solicitation version 1Posted
Lifecycle
- 1Version 1SolicitationArchived
Building 1 HVAC Repair
- 2Version 2SolicitationArchived
Building 1 HVAC Repair
- 3Version 3SolicitationArchived
Building 1 HVAC Repair
- 4Version 4SolicitationArchived
Building 1 HVAC Repair
- 6Version 6SolicitationArchivedCurrent
Building 1 HVAC Repair
Similar Opportunities
Additional Details
Solicitation Number
W50S8Q26QA001
Archive Date
Mar 28, 2026
Office Address
SPRINGFIELD, OH, 45502-8785