GovChime
Notice ID: e35124c511454faa81bba2e76c4bfb84Sources SoughtArchived

Cryogenic Freezers

Archived on May 30, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM CDT
Posted
May 12, 2026
Notice type
Sources Sought
Agency
Department of WarDepartment of the Army

Notice details

Office
US ARMY MEDICAL COMMAND.US ARMY HEALTH CONTRACTING ACTIVITY.W40M MRC0 WEST
Place of performance
San Antonio, Texas, 78264
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W81K00-26-Q-A157
Notice ID
e35124c511454faa81bba2e76c4bfb84

Description

The purpose of this sources sought notice is to conduct market research to determine if responsible sources exist by determining if this effort can be successfully competed and/or set-aside for Small Businesses. The proposed North American Industry Classification System (NAICS) Code is 339112 – Surgical and Medical Instrument Manufacturing which has a size standard of 1,000 employees. The Government will use this information to determine the best acquisition strategy for this procurement. The Government is interested in all large and small businesses to include 8(a), Service-Disabled Veteran-Owned, HubZone, and Women-Owned small business concerns.

The Medical Readiness Contracting Office-West (MRCO-W), JBSA, Fort Sam Houston, Texas, is seeking potential sources who can provide Cryogenic Freezers in support of the Department Pathology at Brooke Army Medical Center (BAMC), JBSA – Fort Sam Houston, Texas. The HexaLux Cryogenic Freezers must adhere to the FULL list of salient characteristics outlined in Attachment 1. This is a one-time purchase.

This is not a solicitation. This information is for planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Contractors responding to this source sought notice are advised that their response does not ensure participation in future solicitations or contract awards. The Government will not reimburse any company or individual for any expense associated with preparation or participation in this research. Interested parties should e-mail responses to the Contract Specialist, Ivette Jefferson, at Ivette.y.jefferson.civ@health.mil and the Contracting Officer, James Davis, at james.m.davis1.civ@health.mil no later than 15 May 2026 by 10:00 AM CST.  

Salient Characteristics - Liquid Nitrogen Freezers

Minimum Clinical Performance Requirements

- Must be able to hold a temperature probe in the interspace of the vat so the probe is not touching samples or directly into liquid nitrogen. It is used to be monitored by REES and Amega currently. Along with additional manual temperature checks as need with Liquid Nitrogen(LN) Thermometer probes.

- The alarms need to physically and audibly with the same ranges as the REES and amega systems, The vat itself needs to be able to be manually set for the ranges. Level of LN varies between models >4 inches, >6 inches, >7inches. Temperature -150- -196 degrees C

-The stem cell bags fit in a rack that has these measurements. 25”x 7”X 0.5”. It holds 3 bags per rack. 2900 cellular therapy bags/ 967 racks

Source Considerations:  No requirements

Biomedical Tech Considerations: Annual maintenance supported by manufacturer 

Certifications:  None

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

No documents available.

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    Cryogenic Freezers

    Notice e35124c511454faa81bba2e76c4bfb84 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W81K00-26-Q-A157

Archive Date

May 30, 2026

Office Address

JBSA FT SAM HOUSTON, TX, 78234-4504