GovChime
Notice ID: 93b2bb1884a74e75a25dc88710b88a8aCombined Synopsis/Solicitation

Particulate Monitors

Archived on October 26, 2021. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:59 AM UTC−06:00
Posted
September 23, 2021
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
Agency
Department of WarDepartment of the Army

Notice details

Office
W0MM TOOELE ARMY DEPOT
Place of performance
Tooele, UT, 84074
Last updated
Dec 4, 2025

Identifiers

Solicitation number
W90WL521Q003X
Notice ID
93b2bb1884a74e75a25dc88710b88a8a

Description

Tooele Army Depot September 23, 2021 The Government seeks a Qualified Contractors for Firm-fixed Price bids for the following Items evaluated on Best-Value: One (1) Brand-Name or Equal- SICK Dust Hunter SP-100 Particulate Optical Scattered Monitor To Include: Sender/receiver unit, DHSP-T4V11NNXX NL 435 mm, up to 400 C, probe material: lance and protection tube SS 1.4571. Control unit MCU-NWODN01000NNNE in wall-mounted cabinet SICK orange, w/o integrated purge air provision. - with LC-Display - with 3 analog and 5 relay outputs - with 4 digital and 2 analog inputs - supply voltage 90...250 V AC T-MOD Ethernet V2,MODBUS TCP, pulse Interface module, with pulse output (MCUP only), with connection cable for MCU/MCUP Purge-air adapter for instrument air Connection: I-Air: 1/4'' inner thread Instrument: Diameter 25 mm Plug connectors and cables Connecting cables, Connection cable Connection type head A: Female connector Connection type head B: Ferrule Cable: 10 m, 5-wire Description: Connection cable, slave, for connection of S/E units Sets and kits, Mounting kit flange/analyzer Description: Mounting kit consisting of: nuts, spring discs Flanges Weld-in flange, Flange with tube Description: Flange with tube, inner diameter 70.2 mm, nominal length 130 mm Material: Stainless steel 1.4571 One (1) Brand-Name or Equal- Filter Set for SICK SP-100 Particulate Monitor To include: Test and monitoring tools, Control filter set Description: Control filter set comprises: filter with approx. 0%, 18%, 40%, 60%, 80% transmission, filter holder, lens cloth, case with insert One (1) Brand-Name or Equal- SICK Weather-Proof aluminum enclosure for SP-100 To include: Device protection (mechanical) Protective housings and protective pipes, Weather proof cover Description: Weather proof cover Material: Aluminum One (1) Brand-Name or Equal- B3 Interface for TS-2-0-DD-R Particulate Monitor Description: 7" screen, analog output, alarm output epa-454/r-98-015 guidance, nema 4 rated, capable of ethernet i/p communication to allen bradley plc One (1) Brand-Name or Equal- B3 Particulate Monitor Description: TS-2-0-SS-R, 24V DC,20" diameter stack,1000 deg f, dynamic induction technology, accuracy <.01 mg/mg3,meets epa-454/r-98-015 guidance, nema 4 Rated One (1) Brand-Name or Equal-B3 Start-up and Set-up Support Description: Start up & setup of b3 TS-2-0-SS-R particulate monitor, includes Technical support for installation & setup All Items must meet EPA 454R98015 Bag Leak Detection Guidance. Monitoring system must have the ability to withstand 750 Deg F at moisture content of 7% non-condensing. Monitoring system must have the ability to withstand 450 Deg F at moisture content of 40% non-condensing. Meet current EPA and MACT requirements for bag house leak detectors with continual monitoring of instrument health and automatic drift and sensitivity testing. The detector will be capable of a hardwired 4-20mA signal on the current control platform but also have capability of Ethernet I/P integration for the future control platform. Items are to be new, unused products. Items to be bid FOB Destination. Shipping Address: Tooele Army Depot 1 Tooele Army Depot Road-Bldg 503 Tooele, UT 84074-5003 TEAD Hours of Operation to accept shipments: Monday-Thursday 7am-430pm All potential bidders must be registered in https://sam.gov/SAM/ prior to bid submission. All potential bidders must provide completed FAR Clause 52.204-24 (P rovided) at the time of bid submission if not already uploaded in SAM. Best Value Evaluation factors shall be price and delivery. Please sign and submit all bids via email to james.m.drak.civ@mail.mil CLAUSE ADDENDUM -Included in Attachment

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:W90WL521Q003X
  1. Combined Synopsis
  1. Combined SynopsisCurrentSep 23, 2021

    Particulate Monitors

    Notice 93b2bb1884a74e75a25dc88710b88a8a on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W90WL521Q003X

Archive Date

Oct 26, 2021

Office Address

TOOELE, UT, 84074-5000