GovChime
Notice ID: 07fc1dcd290849eca19e7d887a2077d1Combined Synopsis/SolicitationArchived

Notice of Intent to Solicit from Only One Source for an Optical Parametric Amplifier (OPA) High Power Ultra Short Pump Laser & Implementation Support

Archived on August 30, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM EDT
Posted
August 10, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
No Set aside used
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
AMC.ACC.ACC-CTRS.ACC-APG.W6QK ACC-APG ADELPHI
Place of performance
White Sands Missile Range, New Mexico, 88002
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911QX-26-Q-A182
Notice ID
07fc1dcd290849eca19e7d887a2077d1

Description

One (1)  ultrafast laser pump source. Reference attachments titled,"Combination Synopsis-Solicitation for Commercial Purchases (Under SAT) OPA USPL Pump Source," "Solicitation - W911QX26QA182" for applicable Provisions, Clauses, Full-Text Clauses and Adelphi Special Instructions & Information, "Salient Characteristics (Light Conversion)," and "Availability of Funds Clause."

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Documents

Files (4)

  • Solicitation - W911QX26QA182.pdf

    4.3 MBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Salient Characteristics (Light Conversion).doc

    91 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Combination Synopsis-Solicitation for Commercial Purchases (Under SAT) OPA USPL Pump Source.docx

    48 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • Availability of Funds Clause.docx

    14 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    Notice of Intent to Solicit from Only One Source for an Optical Parametric Amplifier (OPA) High Power Ultra Short Pump Laser & Implementation Support

    Notice 07fc1dcd290849eca19e7d887a2077d1 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Value Proposition: ThermaSpin, developed by scientists at Los Alamos National Laboratory, provides a reliable, cost-effective way to measure the flow behavior (viscosity) of extremely hot and reactive liquids, such as molten salts and metals, under realistic operating conditions. Unlike existing solutions that are expensive, complex or poorly suited for low-viscosity fluids, this enclosed high-temperature viscometer delivers high sensitivity, small sample requirements and precise atmospheric control, enabling accurate measurements without exposing materials to air or contamination. This capability is critical for industries such as advanced nuclear energy, thermal energy storage and high-temperature materials processing, where fluid properties directly impact system performance, safety and design. By making these measurements more accessible and practical, the ThermaSpin High-Temperature Viscometer reduces development risk, lowers testing costs and accelerates innovation in next-generation energy and industrial systems. The Challenge: Accurately measuring the viscosity of molten salts and other high-temperature liquids is extremely difficult because these materials exist under harsh conditions—temperatures approaching 1,000°C, high chemical reactivity and sensitivity to air and moisture. Traditional measurement techniques often lack the sensitivity needed for these low-viscosity fluids or require specialized, resource-intensive methods that are not widely accessible. In addition, many approaches demand large sample volumes, which can be impractical or hazardous when working with corrosive or toxic materials. Maintaining a controlled environment during testing further complicates measurements, as even minor contamination can alter results. Together, these challenges create a significant barrier to obtaining reliable data on fluid behavior in systems where precise performance understanding is essential. Problems Solved: ThermaSpin High-Temperature Viscometer addresses these challenges by providing a sealed, high-temperature measurement system that can operate reliably in extreme environments while maintaining strict control over sample purity. Its rotational design, coupled with a highly sensitive torsion-based measurement approach, enables accurate detection of the very low forces associated with low-viscosity molten fluids—something conventional instruments struggle to achieve. The enclosed architecture allows operation under inert or controlled atmospheres, preventing contamination from air or moisture, while also supporting smaller sample sizes to reduce risk and material constraints. By integrating temperature resilience, corrosion compatibility and precise mechanical measurement into a single platform, ThermaSpin overcomes the key technical and practical limitations that have historically restricted viscosity characterization in these demanding conditions. Key Advantages: Extreme temperature capability (~1000°C): Reliable operation for molten salts, metals and other high-temperature fluids High sensitivity for low-viscosity liquids: Accurately captures subtle flow behavior that conventional viscometers miss Sealed, controlled environment: Maintains sample purity by preventing exposure to air and moisture Handles corrosive and hazardous materials: Durable design compatible with chemically aggressive substances and smaller sample sizes No specialized infrastructure required: Eliminates dependence on costly, limited-access techniques like neutron imaging Versatile and integration-ready: Adaptable to multiple applications and compatible with inert atmosphere systems (e.g., glove boxes) Market Applications: Advanced Nuclear Energy: Molten salt reactors (MSRs), fusion systems and fuel cycle development Thermal Energy Storage & CSP: High-temperature heat transfer and storage fluids for renewable energy systems Metallurgy & Metal Processing: Molten metal monitoring in refining, casting and advanced manufacturing Chemical Processing: High-temperature and corrosive fluid handling in industrial chemical production Research & Development: National labs, academia and industry studying thermophysical properties of extreme-condition materials Defense & Government Applications: Controlled characterization of hazardous or sensitive molten materials in secure environments Development Status: TRL 3 US Patent pending LA-UR-26-26227 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
-Special Notice04/01/2027
Non-Invasive Ultrasonic Coating Evaluation for Electrochemical Systems Makers of fuel cells, electrolyzers and other electrochemical devices depend on catalyst coatings applied with tight consistency; yet, today’s inspection tools force production to pause so samples can be pulled and studied in a laboratory. SonicCoat, developed by researchers at Los Alamos National Laboratory, offers a faster path: A gentle ultrasonic probe reads how much catalyst has been laid down while the coating line keeps running, giving producers real-time confidence in every layer without slowing throughput or harming the part. The payoff is higher yield, more uniform device performance and lower material cost across a platform that reaches from clean-energy hardware to batteries, solar films and semiconductors. How it Works The SonicCoat method rests on a simple physical fact: Sound travels through an object differently as the object’s makeup changes. A small transducer sends acoustic waves through a coated part and listens for the natural tones, or resonances, that the material rings back. As the catalyst is sprayed onto the surface layer by layer, those resonant tones shift in pitch and loudness in step with how much material has been added, so the acoustic signature becomes a fingerprint of coating thickness and uniformity. Because the reading is taken by sound rather than by scraping, cutting or exposing the part to X-rays, the inspection happens in place and in seconds, and the part continues down the line unharmed. Technology Description SonicCoat applies Acoustic Resonance Spectroscopy (ARS) to the quality control of catalyst-coated gas diffusion layers, the porous electrodes at the heart of fuel cells and electrolyzers. A coated sample is held in fixturing fitted with transducers that excite it across a broad frequency band and record its resonant response, first as a baseline on the bare substrate and then after each successive catalyst layer. Comparing each response against the baseline reveals how the resonance peaks migrate and change in amplitude, and those movements track the amount of platinum catalyst deposited. Testing has shown peaks moving roughly in proportion to added catalyst content, which demonstrates enough sensitivity to distinguish layer-by-layer differences in loading. Because the measurement is non-destructive and adds little time to the coating cycle, the approach fits directly into continuous production rather than diverting samples for laboratory analysis by scanning electron microscopy, energy dispersive X-ray spectroscopy or X-ray fluorescence, the after-the-fact methods relied on today. Catalyst loading is a primary driver of both cost and performance in electrochemical devices, so verified, consistent deposition translates into steadier power output, longer service life and less wasted precious metal. The same principle extends to any process where a thin coating must be monitored on a substrate, and the technique suits scale-up because it neither caps throughput nor limits the number of parts that can be checked. Advantages Inspects coatings in place while the line keeps moving, with no need to stop and pull samples Fully non-destructive, so parts are never cut, scraped or exposed to X-rays Reads catalyst buildup layer by layer for tight, repeatable quality control Relies on simple, low-cost ultrasonic hardware instead of large laboratory instruments Protects costly materials such as platinum by catching over-coating or under-coating early Scales to high-volume production without limiting output Market Applications Fuel Cell and Electrolyzer Manufacturing Battery Manufacturing Solar Energy Semiconductor Fabrication Protective Coatings TRL 4 U.S. Patent pending LA-UR-26-28073 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
-Special Notice12/11/2026
MultiScan-AR from Los Alamos National Laboratory turns a routine mass spectrometry run into a high-resolution portrait of a microbe and its defenses, giving care teams the identity of a pathogen and its antibiotic-resistance profile in minutes to hours rather than the better part of a day. The method works with instruments that clinics and field laboratories already operate, from benchtop analyzers to portable units, so its advanced scanning technique and analysis pipeline add new diagnostic power without demanding an entirely new hardware footprint. For any organization racing to slow the spread of drug-resistant infections, the payoff is faster, more confident treatment decisions and a meaningful edge in patient care and public health. Overview The Multidimensional Mass Fingerprinting for Antibiotic-Resistant Bacteria approach begins by capturing bacteria or fungi from a sample onto a collection material, then breaking those cells open to release their internal parts. The released components are analyzed by mass spectrometry using matrix-assisted laser desorption ionization, a technique that gently and reproducibly converts molecules into measurable ions. Rather than take a single snapshot, MultiScan-AR applies a multidimensional scan that collects fragmentation data across the entire mass range and in both positive and negative charge modes, yielding far richer detail than a standard fingerprint. A dedicated data pipeline then organizes and annotates that complex output into a multidimensional mass fingerprint, allowing the system to identify the organism and flag the subtle molecular changes that signal antibiotic resistance. Technology Description MultiScan-AR is built around a multidimensional tandem mass spectrometry technique that interrogates lysed microbial samples with a level of granularity beyond conventional strain-typing instruments. Antibiotic resistance frequently arises from specific modifications to a cell's machinery, whether inside the cell through inactivating enzymes or at its surface through structures such as efflux pumps, and these differences are usually invisible to tools designed only to separate one species from another. By defining unique tandem fragmentation windows and stepping them across the full mass range, the method gathers MS and MS/MS information that captures those resistance-linked features rather than a coarse profile. The resulting data set is intentionally dense, combining precursor-mass and product ion-level measurements in both ionization modes, and a purpose-built processing pipeline renders it as a single multidimensional mass fingerprint for interpretation. Because the technique layers onto established platforms such as benchtop biotyping analyzers and portable field spectrometers, labs can reach species-level identification and resistance profiling on the order of minutes to hours instead of waiting on culture-dependent workflows. The practical result reinforces a more discriminating readout that distinguishes closely related strains, supports better-informed antibiotic choices and strengthens efforts to contain resistant organisms. Advantages • Delivers pathogen identification and antibiotic-resistance information in minutes to hours • Distinguishes even closely related bacterial strains that routine methods tend to miss • Works with mass spectrometry instruments already present in clinics and field settings, including portable units • Reduces reliance on prior knowledge of the suspected organism, unlike many antibody-based tests • Helps prevent incorrect antibiotic prescriptions and the resistance they encourage • Suits hospital, point-of-care and field-forward environments Market Applications • Clinical Diagnostics (hospital or core laboratories, infectious-disease testing) • Point-of-care Testing (urgent care, bedside diagnostics) • Public Health and Biosurveillance (outbreak monitoring, resistance tracking) • Field-deployable Medicine (military medicine, remote or austere care settings) • Analytical Instrument Platforms (mass spectrometry providers, diagnostic software) • Antimicrobial Research (drug development, resistance studies) TRL 3 U.S. Patent pending LA-UR-26-27335 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
-Special Notice10/01/2026
Scientists at Los Alamos National Laboratory developed the Spectrometer Purposed for Accelerator Testing and Characterization (SPATC) — a portable, easy-to-use device that allows the safe measurement of the power and energy of electron beams from particle accelerators, helping labs test and fine-tune equipment more efficiently. How it Works: SPATC uses a smart, compact design to deliver high-precision beam diagnostics conveniently. At its core, SPATC employs two precisely controlled aluminum wedges that slide together to vary thickness, allowing engineers to analyze how an electron beam’s energy interacts with the material. As the beam passes through these layers, sensors record how much energy is absorbed versus transmitted, and a graphite block captures the remaining beam for accurate current readings. Controlled remotely via computer, SPATC provides real-time data on beam energy and current—without breaking vacuum or requiring complex setup. Designed for flexibility and speed, it offers industries a reliable, low-cost, and portable solution to ensure accelerator performance meets exacting standards for research, manufacturing, or medical applications. Key Advantages: Portable and Compact: Fits into a single rugged case for easy transport and setup at any facility. Fast, Accurate Measurements: Determines beam energy and current in under an hour, minimizing downtime. Remote Operation: Fully controllable from outside the accelerator vault, improving safety and efficiency. Non-invasive Testing: Performs measurements in open air without breaking the accelerator’s vacuum. Precision Engineering: Stepper motor-driven wedges provide fine control over measurement thickness for high accuracy. Enhanced Safety: Reduces radiation exposure by eliminating the need for manual adjustments near the beam. Market Applications: Medical and Radiation Therapy Facilities: Ensures precise calibration of electron beams used in cancer treatment systems. Industrial Accelerator Operations: Enables quick verification of beam performance for material processing, sterilization, and imaging. Research Laboratories and Universities: Provides affordable, portable diagnostics for accelerator-based experiments. Accelerator Manufacturers: Offers a built-in quality assurance tool for testing and characterizing new accelerator systems. Defense and Security Applications: Supports beam validation in systems used for cargo inspection or nondestructive testing. Equipment Service and Maintenance Providers: Allows on-site testing and troubleshooting of accelerators without large diagnostic setups. Development Status: TRL 7 US Patent Pending LA-UR-26-27021 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
-Special Notice02/01/2027
Unlike conventional multichannel atomic magnetometers that require one vapor cell and one optical system for each sensing channel, the patented Multi-Channel Atomic Magnetometer (MCAM) architecture from Los Alamos National Laboratory replaces many independent atomic magnetometers with a single shared vapor cell and optical system that simultaneously generates multiple independent sensing channels. MCAM is a non-cryogenic multi-channel optical quantum sensor in a single module that captures ultra-faint biomagnetic signals from the brain, heart and other sources with sensitivity approaching that of the cryogenic SQUID-based systems that have defined the field for decades. MCAM delivers that performance at roughly one-tenth the per-channel cost without a drop of liquid helium. The module pairs one large alkali-metal vapor cell with broad pump and probe laser beams read out by a photodiode array, providing 16 independent sensing channels in a single housing, scaling into helmet-style arrays of hundreds of channels, and flexing around the patient rather than forcing the patient into a fixed cryogenic dewar. Together, these attributes more easily allow for magnetoencephalography, magnetocardiography and magnetic-particle imaging while accelerating overall magnetic imaging workflows. Ongoing development is aimed at extending the sensing architecture from the centimeter scale characterized in the current prototype toward micrometer-scale spatial resolution, opening a path into cellular-scale magnetic imaging that current cryogenic and room-temperature arrays cannot address. How it Works The MCAM module operates on the spin-exchange relaxation-free (SERF) regime, in which atomic spins of alkali-metal atoms inside a large, sealed vapor cell are aligned by a circularly polarized broad pump laser beam through optical pumping and then interrogated by a linearly polarized broad probe beam propagating along a nearly parallel path. An external magnetic field of interest tilts the aligned atomic spins by an angle proportional to the field strength, and that tilt rotates the polarization plane of the probe beam through the Faraday effect; a photodiode array reads the optical rotation simultaneously at multiple points across the cell, with each photodiode pixel reporting on its own localized sensing volume. A buffer gas inside the cell restricts atomic motion so that the small cell volumes behind each pixel behave as independent sensing channels, a rear mirror folds the beams back through the cell to shorten the stand-off distance to the magnetic source, and transparent Pyrex wire heaters hold the cell at the operating temperature needed for SERF operation. Technology Description The patented shared-cell architecture generates multiple independent sensing channels from a single vapor cell, a single pump beam, a single probe beam, and a single detector array. A pair of broad, co-propagating laser beams, one for optical pumping and the other for probing, traverses the shared vapor cell to manipulate the internal atomic spins, converting the local magnetic field distribution into a spatially resolved optical signal that is read out by a multi-pixel photodetector. Because the buffer gas inside the cell restricts atomic diffusion, each pixel of the detector reports on its own small, spatially distinct region of the cell; therefore, the single module yields a two-dimensional map of the local magnetic field rather than a single-point measurement. Operation in the SERF regime, together with an integrated heating and shielding arrangement and a fold-back optical geometry that shortens the distance from the sensing volume to the magnetic source, sets the sensitivity floor in the low tens of femtotesla per root hertz at low frequency. A development path has been identified to reduce the effective sensing-volume scale from the roughly 1 cm per-channel footprint of the current prototype toward the 1 μm range, which would extend the platform from whole-organ mapping into micro-scale magnetic imaging regimes. Architecturally, the MCAM module is engineered for arrays. Because all channels within a single module share one vapor cell, one laser pair, and one optics assembly, the per-channel parts count and tuning effort drop sharply versus designs that stack many single-channel sensors. Fiber-optic coupling between the laser sources and each sensor head lets modules be repositioned independently, so many modules can be tiled into a conformal helmet or surface array that adapts to head or torso shape and supports configurations that rigid large-cell predecessors cannot accommodate. The design is compatible with several alkali-metal and buffer-gas options and with per-module bias coils that allow each module to be tuned individually inside a larger array. Advantages Development path toward micrometer-scale spatial resolution, a roughly four-order-of-magnitude improvement over the current centimeter-scale prototype and an enabler of cellular-scale magnetic imaging Sensitivity at the low tens of femtotesla per root hertz, comparable to cryogenic SQUID arrays, while using a warm vapor, non-cryogenic architecture Roughly tenfold per-channel cost reduction by sharing one vapor cell, one laser pair and one optics set across 16 channels No liquid cryogens, eliminating recurring cryogen costs and simplifying siting, maintenance and shielding Fiber-coupled, repositionable sensor heads that conform to the patient rather than forcing the patient into a fixed dewar Scalable into helmet-style arrays of hundreds of channels, including a size-adjustable pediatric configuration Shorter sensor-to-source stand-off via rear-mirror beam folding, sharpening spatial resolution of biomagnetic sources Market Applications Medical Diagnostic Imaging (magnetoencephalography systems for epilepsy, stroke and neurodegenerative workups; magnetocardiography for arrhythmia and ischemia screening) Pediatric and Adaptive Neuroimaging (size-adjustable MEG helmets, point-of-care brain monitoring) Micro-scale Biomagnetic Imaging (single-neuron and small-circuit brain activity mapping, high-resolution cardiac tissue mapping) Cancer Diagnostics (magnetic nanoparticle imaging for tumor localization and targeted-therapy tracking) Magnetic Resonance Imaging (low-field/ultra-low field, portable MRI, functional brain imaging) Sensing (low-frequency antennas for underground or undersea links, geomagnetic surveying) Instrumentation (fundamental physics, biomagnetism laboratories, multichannel sensor R&D) Development Status: TRL 4 U.S. Patent No. 11,105,865 LA-UR-26-25904 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
-Special Notice12/13/2026

Additional Details

Solicitation Number

W911QX-26-Q-A182

Archive Date

Aug 30, 2026

Office Address

ADELPHI, MD, 20783-1197