GovChime
Notice ID: f8964e7c428943938b13869188725a7fCombined Synopsis/SolicitationArchived

Liquid Chromatography Mass Spectrometer

Archived on April 30, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM EDT
Posted
April 30, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
Place of performance
Building 753 Cullum Road, West Point NY, 10996, 10996
PSC
6630: CHEMICAL ANALYSIS INSTRUMENTS
Last updated
Oct 31, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911S226U3135
Notice ID
f8964e7c428943938b13869188725a7f

Description

Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states. Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.According to DFARS 204.7304 Solicitation provision and contract clauses (c) This is a COTS item and 252.204-7012 would be exempted from this solicitation - this item does not need to be CMMC 2.0 compliant.

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    Liquid Chromatography Mass Spectrometer

    Notice f8964e7c428943938b13869188725a7f on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

W911S226U3135

Archive Date

Apr 30, 2026

Office Address

FORT DRUM, NY, 13602-5220