GovChime
Notice ID: b40571c7dab44667957f3777caabc3e9Combined Synopsis/Solicitation

60 Klbf Universal Test Machine

Responses closed . Full description on SAM.gov.

Overview

Response deadline
3:00 PM MDT
Posted
June 29, 2026
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
334519: Other Measuring and Controlling Device Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
Place of performance
US ARMY YUMA PROVING GROUND301 C STREET YUMA AZ 85365, 85365
PSC
6650: OPTICAL INSTRUMENTS, TEST EQUIPMENT, COMPONENTS AND ACCESSORIES
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911S226U3510
Notice ID
b40571c7dab44667957f3777caabc3e9

Description

amended to include Set aside code. Model 68FM-300 Floor Mounted Materials Testing System, Force Capacity 300 kN (30,600 kgf, 67,500 lbf) Dual column oor mounted electromechanical testing system including:1. Integrated digital closed-loop control and data acquisition electronics including crosshead extension and load measurement channels (two optional strain channels can be added to software-based systems)2. Automatic recognition and calibration of transducers3. Pre-loaded balls crew drive and crosshead guidance system powered by a bush-less AC servomotor4. Ergonomic handset with two programmable soft keys, start, stop and return functions, variable speed jog and specimen protection5. User selectable system of units: SI, metric and US customary6. Operator protects architecture7. Auto positioning8. Collision mitigation9. Testing Speed Range 0.00005 to 560 mm/min (0.000002 in/min to 22 in/min)10. Crosshead return speed 640 mm/min (25 in/min)11. Type IIF LH (M48 x 2 threaded hole) base tting12. CE mark conformity10-Year Mechanical Systems Warranty English language option Tall Height Load Frame Support Base for Models 68FM-100 and 68FM-300 Load FrameHeight of testing platform is approximately 748 mm (29.4 in), which is 300 mm (11.8 in) over Standard Height. Provides shelf area with capacity rating of 100 kg 220 lbs. evenly distributed. 13. 1 Phase 208 VAC - North America Plug: NEMA L6-20P Maximum Crosshead Travel: 1359 mm (53.5 in)Total System Height for Standard Base: 2287 mm (90 in) Total System Height for Tall Base: 2587 mm (101.9 in) Horizontal test space 575 mm (22.6 in)System footprint (W x D): 1140 mm x 786 mm (44.8 in x 30.9 in) No Pneumatic Air Control Kit Static Load Cell: 300 kN (30,600 kgf, 67,500 lbf) - Type II 14. Tension and Compression15. Type IIF tting (M48 x 2 LH threaded hole)16. Bolt-on design with self identi cation and electrical calibrationSystem installation and training Installation performed by an Instron factory and eld trained Service Engineer Representative. The introduction system can be provided for up to 3 operators. For larger numbers of operators, Instron Training classes are recommended. Some or all the following activities will be performed subject to the system quoted and system con guration:a. Set up of systemb. Safety awareness and general testing safety precautionsc. Make all physical and electrical connections, except 3 phase power and waterd. Mount, install and test all peripheral xtures and transducers, environmental chambers, and any major accessories that are supplied with the systeme. Check correct operation of the system.f. Check correct operation of all electrical components and mechanical assemblies and transducers (where tted)g. Con gure controller and test for correct operation including all adjustments and tuning (includes Console software for Dynamic systems)h. General instruction associated with any hardware elements of the systemi. Review basic operation manuals and any other related documentationj. Calibration and veri cation services are quoted separatelyk. Basic System and Software instruction are quoted separately System Warranty ServicesThe service and support agreement for this system while under warranty includes the following services during the rst year of system ownership (see Instron Terms and Conditions for exact details, limitations and restrictions):a. Parts, labor and travel for repair/replacement for covered items (as de ned in terms and conditions)b. Priority telephone support during normal business hours at our Norwood MA headquarters.c. Direct Veri cation Remindersd. Software Update Noti cationse. Downloadable Software Updates via Instron Connect Software and Customer Portalf. Online Access to Calibration Certi cates and Service Historyg. System Diagnostics via Instron Connecth. Direct Screen Share with Voice via Instron Connecti. Augmented Reality (AR) App Supportj. AI-Driven Troubleshooting Tool via Mobile App and Instron Connect Portal Instron Connect Agreement for New Systems or Software Upgrades/UpdatesInstron Connect includes several technologies that create a secure connection between the testing systems at your facility and Instron. Our problem-solving tools harness innovative technology to rapidly troubleshoot issues and answer your technical questions, increasing productivity, reducing risk and minimizing downtime.Through the Instron Connect Software, Customer Portal, Mobile App and AR Support Tool, you can:k. Share your screen and system diagnostics data with Instron Technical Supportl. Receive calibration and service agreement reminders through the Connect softwarem. Send priority requests for technical support, calibration or on-site servicen. Download software updateso. Access calibration certi cates and service historyp. View your service agreementq. Self-diagnose and solve your system issues with the InSkill AI troubleshooting tool and mobile appr. Receive remote visual support through the AR Support Tool, bringing Instron?s technical support team eyes into your lab

Full description on SAM.gov

Award Overview

Contacts

Contracting Officer

Primary Contact

Documents

Lifecycle

  1. 1
    Version 1Combined Synopsis/Solicitation

    60 Klbf Universal Test Machine

    Notice 872a3e6f74a14842a346ba166b317b54 on SAM.gov

  2. 2
    Version 2Combined Synopsis/Solicitation

    60 Klbf Universal Test Machine

    Notice 8afdf026feb64db9a341e1136963fc19 on SAM.gov

  3. 3
    Version 3Combined Synopsis/SolicitationCurrent

    60 Klbf Universal Test Machine

    Notice b40571c7dab44667957f3777caabc3e9 on SAM.gov

Similar Opportunities

Additional Details

Solicitation Number

W911S226U3510

Archive Date

Jun 29, 2027

Office Address

FORT DRUM, NY, 13602-5220