Safety Air Monitoring Replacement Gas Chromatograph (GC) Phase III

Archived on April 15, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM MDT
Posted
March 24, 2026
Notice type
Combined Synopsis/Solicitation
NAICS
334516: Analytical Laboratory Instrument Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.418TH CSB.W6QM MICC-DUGWAY PROV GRD
Place of performance
Dugway, Utah, 84022
Last updated
Nov 2, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W911S6-26-Q-A011
Notice ID
be3da5dd8b324349a1765ea5e1d2079e

Description

A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments.

Procure one GC instrument with the following specifications:                               

  • Detector capable of detecting halogen containing chemical agents and compounds that also do not contain a phosphorous or sulfur element.  Detector is an alternate to existing Flame Photometric Detector (FPD) and Flame Ionization Detector (FID)
  • Chromatographic column: MXT-1701 phase 
  • Air sampling Quick Change Trap Module with flow rate through the trap of at least 500mL/min
  • External mass flow controller, ability to capture the flow meter readings
  • Oven programmable from ambient to 400℃
  • Cycle time from injection to injection of 15 minutes or less
  • Visible and audible alarms for system faults and sample concentration detections
  • Integrated GC engine, NUMAVIEW with touchscreen display, integrated processor, and storage.
  • Data logging.  Ability to capture instrument set points and measured values such as: sample flow, temperatures, pressures, calibration, concentration, injection type – calibration, service, sample, etc.  Data captured locally with the ability to retrieve and use for other reporting or calculating of sample data.
  • Automatic calibration feature.  Calibration of the instrument using an averaged single point or multi-point calibration curve.  Capable of calibrating and obtaining sample concentrations using the onboard integration engine, and values displayed on the graphical user interface.
  • Heated exhaust to prevent expulsion of water.  Detector exhaust must expel water in gas/vapor form elimination water drip from the instrument detector.
  • Sample bypass capability.  Ability for continuous sample flow at inlet in a bypass state.  A minimum flow of 500mL/min required for bypass capability.
  • GC approximate dimensions - 17” x 11” x 8.5” (width x height x depth)
  • Instrument weight approximately 25 pounds

Shipping: Delivery shall be completed by 30 September 2026 or upon customer notification.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

Files (2)

  • SAMARS Phase 3 Combined Synopsis Solicitation.pdf

    504 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download
  • SAMARS Phase 3 JA Redacted.pdf

    430 KBAdded in Combined Synopsis/Solicitation version 3Posted
    Download

Lifecycle

  1. 3
    Version 3Combined Synopsis/SolicitationArchivedCurrent

    Safety Air Monitoring Replacement Gas Chromatograph (GC) Phase III

    Notice be3da5dd8b324349a1765ea5e1d2079e on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
There is a need for an incubator shaker capable of heating and mixing Erlenmeyer flasks. Flasks working volumes will be ~100 mL each. The incubator must be able to accommodate a capacity of 36 flasks simultaneously. Flasks must be able to be secured to a tray in an incubator, the incubator must be able to be heated to 30-37 deg C, and the tray in the incubator must be able to operate at 200 rpm. These flasks must be able to be heated and mixed for days at a time.
66%
Combined Synopsis11/26/2026
iWorx System Required System Specifications, Minimum 18-channel data recorder with the ability to expand to additional channels. Competing systems typically provide only 2-4 channels. Ability to gang multiple recorders together for expanded data acquisition. Includes 2 channels of wireless ECG/EMG and 3-axis accelerometer capability, with expansion to 16 wired channels. Competing products generally provide only 1-2 channels. Includes an ECG simulator. Integrated Pulse Oximetry, spirometry, grip force, and intensity sensors designed for enhanced measurement accuracy. Pre-calibrated temperature, force, spirometry, and blood pressure sensors, allowing immediate use with minimal setup requirements. Two built-in low-voltage input channels (+/-15V). Built-in isolated constant current high-voltage stimulator. Must be iWire compatible, allowing future expansion and integration of additional sensors and instrumentation. Expandable to a minimum of 34 total channels. Integrated barometric pressure sensor to improve spirometry accuracy without requiring separate external hardware. Minimum 16 digital I/O channels. Minimum 1 audio output channel. Portable design capable of operation through a USB-C power connection. Includes lifetime free LabScribe software updates and an open site license. Includes unlimited online training at no additional cost.
66%
Combined Synopsis11/26/2026
Solicitation Amendment for Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES)
66%
Combined Synopsis11/15/2026
Please see attached RFI and DRAFT Salient Characteristics, please respond accordingly.
66%
Market Research11/06/2026
Amended to include need for analysis software and filter cubes. Amended to include Set aside code. We require an instrument that can acquire real-time data from multiple modes of measurement simultaneously to yield insight about protein behavior. The instrument should be reproducible to facilitate different users acquiring the same results ,have minimal running costs without the use of proprietary consumables, come with software to setup experiments and collect data. Automated experiments should collect fluorescence, absorbance, light scattering, and pH/conductivity data. Automated titration sare required. Temperature and mixing speed must be controllable. The instrument should perform experiments in phase separation, protein interactions, protein aggregation, thermal stability, ion binding, and pH stability
66%
Combined Synopsis09/16/2026

Additional Details

Solicitation Number

W911S6-26-Q-A011

Archive Date

Apr 15, 2026

Office Address

DUGWAY, UT, 84022-5000