Notice ID: 62e7727412c04fb99d2d65cd44448cc7Award NoticeAwardedArchived
Tionesta Dam Security Fence Installation
Awarded on May 21, 2026. Full description on SAM.gov.
Awarded tounder W911WN26PA028 (source: SAM.gov award notice)• $28.8K
Overview
- Posted
- May 21, 2026
- Notice type
- Award Notice
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238990: All Other Specialty Trade Contractors
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION GREAT LAKES AND OHIO.ENDIST PITTSBURGH.W072 ENDIST PITTSBURGH
- Place of performance
- Tionesta, Pennsylvania, 16353
- Last updated
- Oct 29, 2026
- First published
- Last updated on SAM.gov
- Award date
- May 21, 2026
- Award amount (SAM.gov award notice)
- $28.8K
Identifiers
- Solicitation number
- W911WN26PA028
- Notice ID
- 62e7727412c04fb99d2d65cd44448cc7
- Award number (PIID)
- W911WN26PA028
Description
Tionesta Dam Security Fence Installation. Award.
Award Overview
Award Number
W911WN26PA028
Award Amount (SAM.gov award notice)
$28.8K
Award Date
May 21, 2026
Awardee
Awardee UEI
TEH1LGT1UR36
Awardee CAGE Code
9D8J7
Awardee Address
Lawrenceville, PA 16929, UNITED STATES
Line Item Number
0001
Original Solicitation
Notice ID: 62e7727412c04fb99d2d65cd44448cc7
Posted Date: May 21, 2026
Original Response Deadline: Not specified
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
Files (1)
- Download
Site Visit 2 April 2026 Sign-In Sheet.pdf
1.1 MBAdded in Solicitation version 2Posted
Links (4)
- PIEE Solicitation Module Link for W911WN26QA027piee.eb.milPosted
- Web Based Training for the PIEE Solicitation Modulepieetraining.eb.milPosted
- Registration Instructions for the PIEE Solicitation Modulewww.acq.osd.milPosted
- Department of Defense Procurement Toolboxdodprocurementtoolbox.comPosted
Lifecycle
- 2Version 2SolicitationArchived
Tionesta Dam Security Fence Installation
- 5Version 5Award NoticeArchivedCurrent
Type changed from Solicitation to Award Notice
Tionesta Dam Security Fence Installation
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
The U.S. Army Corps of Engineers (USACE), Pittsburgh District has a project that involves the complete replacement of the standing seam metal roof on the Control Tower Building at Mosquito Creek Lake in Cortland, Ohio. The work is to be completed within 365 calendar days after written Notice to Proceed (NTP). Rough Estimate of this non-commercial construction project is between $150,000.00 and $350,000.00. The work includes rerouting existing vent and exhaust pipes through the masonry side wall, installing a new gutter system, and integrating a new, certified, non-penetrating Lightning Protection System. The North American Industrial Classification Code (NAICS) is 238160 - Roofing Contractors. The Small Business Size Standard is $19,000,000.00. Any resultant award will be for one (1) Firm-Fixed Price (FFP) Contract. The Request for Quote (RFQ) will be issued on, or about, 4 September 2026, via the Procurement Integrated Enterprise Environment (PIEE), which posts the opportunity to SAM.gov. The anticipated award date is 13 November 2026. Basis of Award is best value to the Government. Quotes will be evaluated in accordance with (IAW) RFO 12.203(a), price and past performance. The Government reserves the right to reject any quotes that are unrealistically low or exceed available funds for this requirement. Information regarding the U.S. Army Corps of Engineers process for settling requests for equitable adjustments and duration goals to achieve definitization of equitable adjustments for change orders under construction contracts can be found by going to https://www.usace.army.mil/Strategic-Partnerships/Partnering/mod/129895/details/443/ then scrolling down on right hand side of page by clicking on View FFP Contract Changes Playbook Here. | - | Solicitation | 10/30/2026 |
Youghiogheny Resource Managers Building Siding Replacement. USACE, Pittsburgh District, has an upcoming requirement to replace the siding of the Resource Managers Office at Youghiogheny River Lake. The work described herein shall be performed at the Youghiogheny Resource Managers Office (RMO) building located within the Youghiogheny River Lake project area in Confluence, Pennsylvania. The building currently serves as administrative office space for the U.S. Army Corps of Engineers. The RMO building was constructed in 1986 and is a multi-level, timber-framed structure built into the hillside overlooking the impoundment side of the dam. The exterior walls consist of 2x6 wood stud framing with 6-inch fiberglass batt insulation (R-19, foil-faced). Interior partitions consist of 2x4 wood studs with 1/2-inch gypsum wallboard. The existing exterior wall assembly consists of 1/2-inch asphalt-saturated fibrous sheathing with 5/8-inch cedar-faced T1-11 plywood siding, for a combined nominal thickness of 1-1/8 inches. Exterior trim and fascia consist of various widths of cedar lumber. The building is supported by cast-in-place concrete footings and 12-inch concrete masonry unit (CMU) foundation walls. The rear wall section and balcony framing are supported by 4 feet-0 inches wide by 5 feet-0 inches deep concrete footings, laminated wood columns (8-3/4 inches x 15 feet-0 inches), and laminated wood beams (8-3/4 inches x 15 feet-0 inches).This project consists of the removal and replacement of the existing exterior wall cladding system. The Contractor shall remove and dispose of the existing T1-11 siding and 1/2-inch asphalt-saturated fibrous sheathing in their entirety. The Contractor shall furnish and install a new exterior wall assembly consisting of 1/2-inch APA-rated structural wood sheathing, a continuous weather-resistive barrier (WRB), 3/8-inch nominal preservative-treated wood furring strips, and 5/16-inch fiber cement lap siding in accordance with manufacturer requirements. The new wall assembly is intended to match the existing wall thickness (approximately 1-1/8 inches) to maintain alignment with existing window and door openings. Minor dimensional variation within normal construction tolerances are acceptable and shall not require modification or resetting of existing windows and doors. The Contractor shall not reset, relocate, or otherwise modify existing windows and doors. Furring strips shall be installed vertically over the WRB at a maximum spacing of 16 inches on center and shall be fastened through the sheathing into wall framing members. Fiber cement siding shall be installed horizontally over the furring strips and fastened through the furring and sheathing into wall framing members. Furring strips are intended to provide a drainage and ventilation cavity and shall not be used as the sole fastening substrate for the fiber cement lap siding. The Contractor shall ensure that all fiber cement lap siding edges are supported by framing members or approved blocking in accordance with manufacturer requirements. The Contractor shall furnish and install all required trim at windows, doors, corners, and transitions. Trim material shall be fiber cement. The cedar hand railing on the balconys is to be new capped PVC or capped composite decking of matching color to fiber cement board siding. The Contractor shall provide complete flashing at all required locations, including but not limited to head flashing at windows and doors, Z-flashing at horizontal joints and transitions, and kick-out flashing at roof-to-wall intersections. All flashing shall be integrated with the WRB in a shingle-lap manner to maintain a continuous drainage plane. The work shall be completed within 180 after written Notice to Proceed. Disclosure of Magnitude of Construction (FAR 36.204 and DFARS 236.204) The acquisition will be procured as 100% Set-Aside for Small Business. The resulting award will be for one (1) Firm-Fixed-Price (FFP) Contract. All responsible Quoters are encouraged to participate. The Request for Quotes (RFQ) will be issued on or about 19 August 2026, online through Procurement Integrated Enterprise Environment (PIEE) which posts the opportunity to SAM.gov; therefore, requests for hardcopies of the solicitation will not be honored. The North American Industrial Classification System (NAICS) Code for this acquisition is 238170 - Siding Contractors. The Small Business Size Standard for this NAICS Code is $19,000,000.00.In order to submit a Bid on this project, your company must-1) Be registered in System for Award Management (SAM) and maintain an active registration status. 2) Be registered in the Procurement Integrated Enterprise Environment (PIEE) for the Solicitation Module with the PROPOSAL MANAGER Manger role. System for Award Management (SAM) Registration Registering in SAM.gov includes both entity validation and entity registration. To register in SAM: a. Navigate to SAM.gov b. Select Sign-In (top right)c. Select Create an Account then Follow the Instructions. d. After Account is Set-up, Select Sign In. e. Under the Entity Management widget, Select button. f. Select Register Entity. As part of entity registration, a Unique Entity ID will be assigned. For Additional Information on SAM To Register Your Entity (company), please visit https:/www.fsd.gov/gsafsd_sp?id=gsa_index . Here you will find the following, Get Started with Your Registration Check Registration Status ACTIVE, INACTIVE, PENDING Update Your Registration Become an Entity Administrator Validate Your Entity *Access User Guides *By selecting this option, you can obtain a Quick Start Guide for Contract Registrations. Also, here you will find in addition to the User Guides - FAQs, Videos, and Definitions. PLEASE NOTE It is mandatory that all companies be registered in SAM in order to receive federal contracts. There is no charge to register or maintain your company (entity) registration.Login.gov manages usernames and passwords for SAM.gov. *Important* Registration Information Registration can take at least ten (10) business days to be active in SAM.gov. Registration must be in active status upon offer submission and remain active during award period. Registration must be renewed every 365 days to remain active. The Federal Service Desk (FSD) for SAM questions, may be contacted. Phone Number: 866-606-8220Hours of Operation: Monday-Friday 8 a.m. to 8 p.m. ET Procurement Integrated Enterprise Environment (PIEE) Solicitation Module Registration To register for PIEE follow the below instructions. Register in PIEE: a. Navigate to https://piee.eb.mil/b. Select Register [top right]c. Select Vendor d. Create a User ID and Password and follow the prompts [next]e. Create Security Questions [next]f. Complete your User Profile Information [next]g. Complete your Supervisor or Approving Official Information [next]h. Complete Roles i. Step 1. Select SOL-Solicitation ii. Step 2. Select Proposal Manager iii. Step 3. Click Add Roles iv. Step 4. Fill in your Location Code (CAGE Code) [next]i. Provide a justification for your registration [next]j. Follow the remaining prompts to submit your registration The Procurement Integrated Enterprise Environment (PIEE) help desk may be reached by calling telephone number 866-618-5988 for assistance. | - | Solicitation | 09/28/2026 |
USACE, Pittsburgh District, has an upcoming requirement to replace the siding of the Resource Managers Office at Youghiogheny River Lake. The work described herein shall be performed at the Youghiogheny Resource Managers Office (RMO) building located within the Youghiogheny River Lake project area in Confluence, Pennsylvania. The building currently serves as administrative office space for the U.S. Army Corps of Engineers. The RMO building was constructed in 1986 and is a multi-level, timber-framed structure built into the hillside overlooking the impoundment side of the dam. The exterior walls consist of 2x6 wood stud framing with 6-inch fiberglass batt insulation (R-19, foil-faced). Interior partitions consist of 2x4 wood studs with 1/2-inch gypsum wallboard. The existing exterior wall assembly consists of 1/2-inch asphalt-saturated fibrous sheathing with 5/8-inch cedar-faced T1-11 plywood siding, for a combined nominal thickness of 1-1/8 inches. Exterior trim and fascia consist of various widths of cedar lumber. The building is supported by cast-in-place concrete footings and 12-inch concrete masonry unit (CMU) foundation walls. The rear wall section and balcony framing are supported by 4 feet-0 inches wide by 5 feet-0 inches deep concrete footings, laminated wood columns (8-3/4 inches x 15 feet-0 inches), and laminated wood beams (8-3/4 inches x 15 feet-0 inches).This project consists of the removal and replacement of the existing exterior wall cladding system. The Contractor shall remove and dispose of the existing T1-11 siding and 1/2-inch asphalt-saturated fibrous sheathing in their entirety. The Contractor shall furnish and install a new exterior wall assembly consisting of 1/2-inch APA-rated structural wood sheathing, a continuous weather-resistive barrier (WRB), 3/8-inch nominal preservative-treated wood furring strips, and 5/16-inch fiber cement lap siding in accordance with manufacturer requirements. The new wall assembly is intended to match the existing wall thickness (approximately 1-1/8 inches) to maintain alignment with existing window and door openings. Minor dimensional variation within normal construction tolerances are acceptable and shall not require modification or resetting of existing windows and doors. The Contractor shall not reset, relocate, or otherwise modify existing windows and doors. Furring strips shall be installed vertically over the WRB at a maximum spacing of 16 inches on center and shall be fastened through the sheathing into wall framing members. Fiber cement siding shall be installed horizontally over the furring strips and fastened through the furring and sheathing into wall framing members. Furring strips are intended to provide a drainage and ventilation cavity and shall not be used as the sole fastening substrate for the fiber cement lap siding. The Contractor shall ensure that all fiber cement lap siding edges are supported by framing members or approved blocking in accordance with manufacturer requirements. The Contractor shall furnish and install all required trim at windows, doors, corners, and transitions. Trim material shall be fiber cement. The cedar hand railing on the balconys is to be new capped PVC or capped composite decking of matching color to fiber cement board siding. The Contractor shall provide complete flashing at all required locations, including but not limited to head flashing at windows and doors, Z-flashing at horizontal joints and transitions, and kick-out flashing at roof-to-wall intersections. All flashing shall be integrated with the WRB in a shingle-lap manner to maintain a continuous drainage plane. The work shall be completed within 180 after written Notice to Proceed. The acquisition will be procured as 100% Set-Aside for Small Business. The resulting award will be for one (1) Firm-Fixed-Price (FFP) Contract. All responsible Quoters are encouraged to participate. The Request for Quotes (RFQ) will be issued on or about 19 August 2026, online through Procurement Integrated Enterprise Environment (PIEE) which posts the opportunity to SAM.gov; therefore, requests for hardcopies of the solicitation will not be honored. The North American Industrial Classification System (NAICS) Code for this acquisition is 238170 - Siding Contractors. The Small Business Size Standard for this NAICS Code is $19,000,000.00. In order to submit a Bid on this project, your company must- Be registered in System for Award Management (SAM) and maintain an active registration status. Be registered in the Procurement Integrated Enterprise Environment (PIEE) for the Solicitation Module with the PROPOSAL MANAGER Manger role. System for Award Management (SAM) Registration Registering in SAM.gov includes both entity validation and entity registration. To register in SAM: Navigate to SAM.gov Select Sign-In (top right) Select Create an Account then Follow the Instructions. After Account is Set-up, Select Sign In. Under the Entity Management widget, Select “Get Started” button. Select Register Entity. As part of entity registration, a Unique Entity ID will be assigned. For Additional Information on SAM To Register Your Entity (company), please visit https:/www.fsd.gov/gsafsd_sp?id=gsa_index . Here you will find the following, Get Started with Your Registration Check Registration Status – ACTIVE, INACTIVE, PENDING Update Your Registration Become an Entity Administrator Validate Your Entity *Access User Guides *By selecting this option, you can obtain a Quick Start Guide for Contract Registrations. Also, here you will find in addition to the User Guides - FAQs, Videos, and Definitions. PLEASE NOTE It is mandatory that all companies be registered in SAM in order to receive federal contracts. There is no charge to register or maintain your company (entity) registration. Login.gov manages usernames and passwords for SAM.gov. *Important* Registration Information Registration can take at least ten (10) business days to be active in SAM.gov. Registration must be in active status upon offer submission and remain active during award period. Registration must be renewed every 365 days to remain active. The Federal Service Desk (FSD) for SAM questions, may be contacted. Phone Number: 866-606-8220 Hours of Operation: Monday-Friday 8 a.m. to 8 p.m. ET Procurement Integrated Enterprise Environment (PIEE) Solicitation Module Registration To register for PIEE follow the below instructions. Register in PIEE: a. Navigate to https://piee.eb.mil/ b. Select Register [top right] c. Select Vendor d. Create a User ID and Password and follow the prompts [next] e. Create Security Questions [next] f. Complete your User Profile Information [next] g. Complete your Supervisor or Approving Official Information [next] h. Complete Roles i. Step 1. Select SOL-Solicitation ii. Step 2. Select Proposal Manager iii. Step 3. Click Add Roles iv. Step 4. Fill in your Location Code (CAGE Code) [next] i. Provide a justification for your registration [next] j. Follow the remaining prompts to submit your registration The Procurement Integrated Enterprise Environment (PIEE) help desk may be reached by calling telephone number 866-618-5988 for assistance. | - | Pre-Solicitation | 08/19/2026 |
Amendment 01. The Mobile District COE has a need for one MATOC for a full range of vertical construction, renovation, repair, and some incidental design task orders for general construction primarily at 12 locations in AL, FL, GA, and MS. * It is the Offeror's responsibility to monitor SAM.gov/PIEE for all solicitation and amendment specifics. | - | Solicitation | 11/05/2026 |
Amendment 0004 | - | Solicitation | 11/09/2026 |
Additional Details
Solicitation Number
W911WN26PA028
Archive Date
Jun 5, 2026
Office Address
PITTSBURGH, PA, 15222-4198