Notice ID: 0cecfcf307bea8a84b0c86852b64b023Combined Synopsis/Solicitation
Expand Fire Suppression System Bldg 1001
Archived. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 10:00 AM UTC−05:00
- Posted
- March 29, 2019
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 238220: Plumbing, Heating, and Air-Conditioning Contractors
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- W7M2 USPFO ACTIVITY FLANG 125
- Place of performance
- 125th Fighter Wing Jacksonville International Airport, 14300 FANG Dr., Jacksonville, FL, 32218
- PSC
- Z: MAINT, REPAIR, ALTER REAL PROPERTY
- Last updated
- Jan 23, 2026
Identifiers
- Solicitation number
- W911YN18B5001
- Notice ID
- 0cecfcf307bea8a84b0c86852b64b023
Description
Expand Fire Suppression System Bldg 1001 Flt. Line Avionics / Tool Room / Tire Shop This is a Invitation for Bids (IFB) for a small business setaside under North American industry classification (NAICS) code is 238220. The size standard is $15M. The magnitude of construction is between $100,000 and $250,000 with a 150 calendar Day Period of Performance. The contractor shall provide all personnel, equipment, tools, materials, supervision, transportation, and other itemsand services necessary to complete the work as Described in this Statement of Work. Work location is at the Air National Guard Base, Jacksonville International Airport, in Duval County, Florida. The project scope is to expand the automatic fire suppression system in Building 1001, to include the Flight LineAvionics offices and the Tool Room / Tire Shop under the mezzanine (combined 4652 SQ FT.). Install the additional wet pipe fire extinguishing sprinkler systems for complete fire protection coverage throughout the Flight Line Avionics offices and the Tool Room / Tire Shop under the mezzanine (combined 4652 SQ FT).Work shall include field surveys, analysis, flow calculations and drawings as required. Remove the addressable fire alarm detection devices that are located in the newly protected areas, as they are no longer required. Reprogram the Fire Alarm Control Panel (FACP) and D21 Monaco Radio Reporting system with central receivers located in Buildings 5 and 44 as needed and recertify system.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
Select documents to download
Showing 10 of 10 items
Document | Source | Agency | Posted Date | File Size | Actions | |
|---|---|---|---|---|---|---|
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - | |||
| Combined Synopsis/Solicitation | DEPT OF THE ARMY | Mar 29, 2019 | - |
Lifecycle
Solicitation:
W911YN18B5001- Combined Synopsis
- 9×Combined SynopsisCurrentAug 10, 2018
Expand Fire Suppression System Bldg 1001