Notice ID: 0adc0653340c058589f66aee7856df34Solicitation
Z--Replace Manual Tie Switch with New Automatic Tie Breaker
Archived on January 24, 2012. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 12:00 AM UTC+01:00
- Posted
- December 20, 2011
- Notice type
- Solicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business Set Aside
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- W075 ENDIST SACRAMENTO
- Place of performance
- USACE District, Sacramento 1325 J. Street, Sacramento CA 95814 US
- PSC
- Z: MAINT, REPAIR, ALTER REAL PROPERTY
- Last updated
- Dec 5, 2025
Identifiers
- Solicitation number
- W9123812Q0007
- Notice ID
- 0adc0653340c058589f66aee7856df34
Description
(a) Content: Pre-solicitation Notice - Synopses 1. Action Code: P 2. Date: 11/09 3. Year: 2011 4. Contracting Office Zip Code: 95814 5. Classification Code: Z2AZ - Repair or Alteration of other Administrative Facilities and Service Buildings 6. Contracting Office Address: United States Army Corps of Engineers, 1325 J. St. Sacramento, CA. 7. Subject: Replace Manual Tie Switch with Automatic Tie Breaker 8. Proposed Solicitation Number: W91238-12-Q-0007 9. Closing Response Date: 28 Dec 2011 10. Contact Point or Contracting Officer: MSG Haynes - eunice.haynes@usace.army.mil 11. Contract Award and Solicitation Number: To Be Determined (TBD) 12. Contract Award Dollar Amount TBD 13. Contract Line Item Number: NA 14. Contract Award Date: TBD 15. Contractor: TBD 16. Description: Demolish/remove: Existing manual tie switch. Supply and install: New Automatic Tie Breaker 17. Place of Contract Performance: Building 100, DDJC Tracy Site 18. Set-aside Status: Service Disabled Veterans Owned Small Business Concerns (b) Solicitation specifications will not be provided in hard paper copy or CD format. The solicitation and all amendments for this acquisition shall be posted on FedBizOpps Government website www.fbo.gov on 28 November 2011. It is the responsibility of the contractor to check FedBizOpps frequently for any amendments or changes in the solicitation. (c) Description: Contractor shall Demolish/remove Existing manual tie switch - Square D, 1200A, 600VAC, single through, not fusible, Cat# HU368, Type 1 enclosure. Demolish, remove and transport material from site to DRMO, Lathrop, CA., per government environmental regulations and DRMO protocol. Supply and install one new automatic tie breaker, 1200A, 600VAC, AIC-100 K symmetrical (Siemens, GE or approved equal). Supply and install new control panel with required digital relays (Basler, Schneider Electric or approved equal), digital controls (Westinghouse, GE or approved equal) and required voltage and current sensors to enable second generator to come on line when first generator fails to start and vice versa. Existing generators shall not run parallel with each other or local utility. Tie Breaker and control panel shall be in same NEMA I enclosure. Control panel shall be tested at site for all the features as mentioned in Emergency Operation Requirements. Provide one 750 KVA back up portable generator and accessories for the time when both existing generators are in-operable, during construction phase. Portable generator shall be adequately equipped to feed emergency UPS bus. Create single line diagram of entire building 100 power distribution system including new automatic tie breaker control circuit and provide three sets of as built drawings. Partial existing single line diagram may be available for reference. New drawings shall be stamped by PE registered with the state of California and have minimum of five years experience with designing generator control circuits. Entire work and Field Testing shall be performed on weekends and holidays. Display tie breaker operation instructions in a laminated framed board in front of tie breaker control panel. (d) Emergency Operation Requirements: The following field tests shall be conducted to the satisfaction of Project Engineer: When local utility (PG&E) power source to building 100 is interrupted, both the generators should come on line and operate independently with tie breaker open. When local utility (PG&E) power source to building 100 is interrupted and both generators are operational. If anyone of the generators fails, tie breaker should close after failed generator breaker is locked out. When failed generator comes back on during PG&E power interruption, tie breaker should open first and then allow the failed generator breaker to close. If both generators fail or not in service, tie breaker should remain open. (e) General: Contractor shall provide three sets of operations manuals. Provide operations, maintenance and safety training for new automatic tie breaker and controls to plant personnel (minimum 4 Hrs). Submit shop drawings for approval, prior to installation, of all the material and control circuits. Contractor shall submit material demolition and disposal plan and get approval from DLA environmental group and DRMO prior to equipment demolition. Manual tie switch shall be demolished and new tie breaker shall be installed and tested as per all applicable codes including but not limited to ANSI, ASME, ASTM, EGSA, MSS, NEMA, SAE, NEC, NFPA, CEC, UFC and IEEE and attached specifications. (1) National Stock Number (NSN) : Not Applicable (2) Specification: Demolish and remove existing manual tie switch - Square D, 1200A, 600VAC, single through, not fusible, Cat# HU368, Type 1 enclosure. Provide and Install one (1) new, automatic tie breaker, 1200A, 600VAC, AIC-100 K symmetrical (3) Quantity: One (1) - Replace one (1) Manual Tie Switch with one (1) New Automatic tie breaker. (4) Unit of Issue: Lump sum (5) Destination Information: Building 100, DDJC Tracy Site, Defense Location Agency (DLA) San Joaquin, CA. (6) Delivery/Duration of Contract Period/ Performance for Schedule: Entire project including all Field Testing shall be completed no later than (NLT) 90 calendar days after notice to proceed (NTP) (7) Proposed Contract Action: (i) This acquisition is proceeding as a Request for Quote (RFQ). This RFQ is a Service Disabled Veteran Owned Small Business Set-Aside (SDVO) and all responsible sources may submit a quotation which shall be considered by the agency. The award decision will be based on the lowest acceptable price that specifies a product that meets the technical specifications of the requirements. (ii) Estimated Cost Range is between $25,000 - $100,000 (iii) The anticipated award date is TBD (8) This procurement is subject to the Buy American Act- Construction Materials FAR 52.225-9 (9) Technical data including plans, drawings and specifications will be furnished through FedBizOpps with the solicitation at https://www.fedbizopps.gov This Procurement will be conducted under FSC code: Z2AZ; NAICS Code: 238210. The size standard for this code is $14,000,000.00. Questions may be directed to the Contract Specialist, MSG Haynes at email, eunice.a.haynes@usace.army.mil An organized site visit/pre-proposal conference will be scheduled at project location Building 100, DDJC Tracy Site, approximately one week after the solicitation is posted on 6 December 2011. Attendance for the site-visit is not mandatory. For all attendees requiring access information to location please contact project manager Mr. Duane Balch no later than 3 working days before the scheduled site visit Duane.C.Balch@usace.army.mil phone 916 557-7450 Participation in the site visit will require the following information: Name: Last-four digits of attendees' social security number: Company Name: A phone number and (POC) point of contact email address A confirmation will be sent to POC email address. It is anticipated that the solicitation will be issued on or about 28 November 2011, for downloading at the Government website at http://www.fedbizopps.gov/ Contractors are advised that this project may be delayed, cancelled or revised at any time during the selection process
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Carol A. Dones
Contracting Officer
Documents
No documents available.
Lifecycle
Solicitation:
W9123812Q0007- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- 5×Pre-SolicitationNov 10, 2011
Z--Replace Manual Tie Switch with New Automatic Tie Breaker
- SolicitationCurrentDec 20, 2011
Z--Replace Manual Tie Switch with New Automatic Tie Breaker
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
W9123812Q0007
Archive Date
Jan 24, 2012