Notice ID: 4499e19bf353c149f719073d7e19e7e5Presolicitation

Y--John Day Powerhouse Bridge Cranes Rehabilitation

Archived on September 27, 2009. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 AM UTC−05:00
Posted
July 14, 2009
Notice type
Presolicitation
Agency
Department of WarDepartment of the Army

Notice details

Office
W071 ENDIST PORTLAND
Place of performance
Portland District, US Army Corps of Engineers Contracting Division (CENWP-CT_, P.O. Box 2946 Portland OR 97208-2946 US
PSC
Y: CONSTRUCT OF STRUCTURES/FACILITIES
Last updated
Sep 25, 2026

Identifiers

Solicitation number
W9127N08R0020
Notice ID
4499e19bf353c149f719073d7e19e7e5

Description

The U.S. Army Corps of Engineers (USACE), Portland District (NWP) has a requirement for John Day Powerhouse Bridge Cranes, with a Magnitude of Construction ranging between $5,000,000.00 and $10,000,000.00. The work includes all operations required to provide the design and to perform the work required to rehabilitate both existing 375-ton bridge cranes as well as rail replacement and power distribution installation at the John Day Powerhouse. The bridge cranes shall be rerated, tested and certified at 385 tons. Work includes: a. Structural Work to replace operator cabs including new captain-style operator's chair with integrated control console on both the north and south bridge cranes. b. Crane Rail Track Replacement. c. Mechanical Work includes: replace gearboxes, replace all wire rope, replace all motors, brakes, and replace couplings, replace seals and bearings, align machinery and gearing to obtain proper alignment, rebuild main and auxiliary lower and upper blocks. d. Electrical Work includes: Replace the complete existing power and control systems and associated equipment including: main line conductors, panels, enclosures, transformers, wiring, wireways, festoons, and conduit; motors and brakes with winding and enclosure heaters; gear case heaters; limit switches; and lighting. As part of the new control system, provide new flux-vector variable frequency drives (VFD) for all hoists, and provide open-loop vector VFDs for all travel. As part of the new control system, provide remote (radio) control. Provide new load cells and indication system for all hoists. Provide indication in the operator's cab and on the radio remote transmitter. Provide PA system for both cranes Detailed specification will be inclusive in the solicitation package. A Site Safety and Health Officer (SSHO) shall be provided for all new contracts with this District. For this project, the person that will act as the SSHO is required to have a minimum of 3 years safety work with similar projects and a 30 Hour OSHA construction safety class (or equivalent) taken within the last 3 years. The SSHO may have no other duties for this work except function as the on-site CQC Manager. This procurement is open to both small and large business concerns; large businesses are required to submit a subcontracting plan. The NAICS Code is 811310 and the small business size standard is $7 million. Large business will be required to submit a small business subcontracting plan. The Magnitude of Construction is between $5,000,000.00 and $10,000,000.00. Interested business concerns must be enrolled in the Central Contractor Registry (CCR) at www.ccr.gov to conduct business with the Department of Defense. A Request for Proposal (RFP) utilizing the Best Value/LPTA method will be issued. Evaluation criteria will be provided in the solicitation, and a single firm fixed-price contract may be negotiated as a result of this procurement. The solicitation for this project will be issued in electronic format on/or about 24 July 2009 with a proposal due date 30 days after issuance; a notice and link to download this solicitation via Army Single Face to IndustryASFI (https://acquisition.army.mil/asfi/default.cfm) will be posted on the Federal Business Opportunity (www.fbo.gov) when the solicitation is available for download. Interested parties must be registered in FedTeDS to download the solicitation information. Interested parties are responsible for checking the referenced websites for any update(s). The Government is not responsible for any loss of Internet connectivity or for any parties inability to access the document posted at the referenced websites. Technical Point of Contact is Steven Sipe at Steven.C.Sipe@usace.army.mil . Administrative matters related to the contract can be addressed by e-mail to Ken Piper at Kenneth.G.Piper@usace.army.mil. All inquiries regarding this solicitation are to be submitted via Bidder Inquiry. Telephone and email inquiries will not be accepted. Bidder Inquiry is a web-based program that allows bidders to post questions regarding the solicitation and to view all questions by other bidders and answers by USACE. Bidder Inquiry instructions will be detailed in the solicitation.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Barbara White, 503-808-4621 Portland District, US Army Corps of Engineers

Documents

No documents available.

Lifecycle

Solicitation:W9127N08R0020
  1. Pre-Solicitation

Formal solicitation typically follows within 30–60 days. (estimate)

  1. 2×
    Pre-SolicitationCurrentApr 18, 2008

    Y--John Day Powerhouse Bridge Cranes Rehabilitation

    Notice 4499e19bf353c149f719073d7e19e7e5 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W9127N08R0020

Archive Date

Sep 27, 2009