GovChime
Notice ID: a15fb13a7ff245ff8a84e96a48f96042Award NoticeAwarded

John Day SQ and SU Boards Replacement

Awarded on November 30, 2017. Full description on SAM.gov.

Awarded tounder W9127N18C0009 (source: SAM.gov award notice)• $7.5M

Overview

Posted
December 1, 2017
Notice type
Award Notice
Agency
Department of WarDepartment of the Army

Notice details

Office
W071 ENDIST PORTLAND
Place of performance
John Day Lock and Dam, Sherman County, Oregon and Klickitat County, Washington
PSC
Z: MAINT, REPAIR, ALTER REAL PROPERTY
Last updated
Dec 4, 2025
Award date
Nov 30, 2017
Award amount (SAM.gov award notice)
$7.5M

Identifiers

Solicitation number
W9127N17R0031
Notice ID
a15fb13a7ff245ff8a84e96a48f96042
Award number (PIID)
W9127N18C0009

Description

Synopsis: The U.S. Army Corps of Engineers (USACE) Portland District intends to solicit construction firms who are interested in submitting a competitive firm-fixed-price proposal for this project. This announcement is for the replacement of the John Day SQ and SU Boards at the John Day Lock and Dam located in Sherman County, Oregon and Klickitat County, Washington. Project Description: The U.S. Army Corps of Engineers, Portland District, has a requirement to replace the SQ and SU Boards at the John Day Lock and Dam located in Sherman County, Oregon and Klickitat County, Washington. The project scope includes, but is not limited to: 4.16 KV SP SWITCHGEAR o Replace protective relays and wiring o Update relay output annunciation and wiring o Test and assist commissioning of new relays and system 480 V STATION SERVICE SWITCHGEAR o Replace double ended switchgear o Replace protective relays and wiring o Replace control equipment and wiring o Add an adjacent Remote Operating Panel o Update annunciation and wiring o Replace 4.16 kV Supply Conductors o Replace AC & DC feeder conductors as shown and if needed (optional items) o Replace 4.16kV/480VAC transformers at SQO1, SQO2, & SQ1-4 o Add High Resistance Grounding system to 480V system o Replace 4.16kV manually operated disconnect switches at SQO2 and SQ1-4 with 5 kV load break switches 480 VAC & 125/250 VDC MOTOR CONTROL CENTERS o Replace SU Boards with new; including Main Breakers o Maintain existing Bus 1 & Bus 2 configuration o Replace feeder conductors where necessary. SU feeders to be included as an optional bid item. Acquisition Strategy: The solicitation will be a request for proposal (RFP). The Best Value Tradeoff source selection process will be used to evaluate proposals. Evaluation criteria will be stated in the RFP. The Government will include options in the RFP. This acquisition will result in a single firm-fixed-price contract. Magnitude of Construction: The estimated cost of the project is between $10,000,000 and $25,000,000. Set Asides and Codes: This is an unrestricted, full and open procurement. This effort is classified through the North American Industry Classification System (NAICS) under code 238210 - Electrical Contractors and Other Wiring Installation Contractors ($15.0M). The FSC is Z2KA - Repair or Alteration of Dams. Proposal Period: The solicitation is scheduled for release on or about 13 July 2017. The tentative date for receipt of proposals is on or about 13 August 2017. Plans and Specifications: The solicitation will be posted on the Federal Business Opportunities website, https://www.fbo.gov/, once it is issued. Firms are requested to register electronically to receive a copy of the solicitation when it is issued. System for Award Management (SAM): Offerors must register in the SAM at https://www.sam.gov/portal/public/SAM/ prior to receiving an award. Point of Contact: The USACE-NWP Contracting Office will be the sole point of contact for this action. E-mail responses to the Primary Point of Contact, Mr. Ryan S. Shoemaker at ryan.s.shoemaker2@usace.army.mil. Email is the preferred method for receiving responses to this pre-solicitation notice. THIS PRE-SOLICITATION NOTICE IS FOR THE PURPOSE OF INFORMING INDUSTRY THAT THIS SOLICITATION WILL BE POSTED ON FBO ON OR ABOUT 13 JULY 2017. THIS NOTICE IS NOT A REQUEST FOR PROPOSALS AND PROPOSALS RECEIVED AS A RESULT OF THIS PRE-SOLICITATION NOTICE WILL NOT BE ACCEPTED OR EVALUATED. THE GOVERNMENT RESERVES THE RIGHT TO CANCEL THIS SOLICITATION EITHER BEBORE OR AFTER THE CLOSING DATE. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS PRE-SOLICITATION NOTICE OR ANY FOLLOW-UP INFORMATION REQUEST.

Full description on SAM.gov

Award Overview

Award Number

W9127N18C0009

Award Amount (SAM.gov award notice)

$7.5M

Award Date

Nov 30, 2017

Awardee

Awardee UEI

EURDTQUCGAV5

Original Solicitation

Notice ID: a15fb13a7ff245ff8a84e96a48f96042

Posted Date: Dec 1, 2017

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

5
  • W912EF22C0002
    PICK ELECTRIC, INC.
    Department of DefenseNAICS 238210
    $14.4MSigned Jun 23, 2026
  • W912EF22C0002
    PICK ELECTRIC, INC.
    Department of DefenseNAICS 238210
    $14.2MSigned Feb 4, 2026
  • W912EF22C0002
    PICK ELECTRIC, INC.
    Department of DefenseNAICS 238210
    $14.2MSigned Nov 17, 2025
  • W912EF22C0002
    PICK ELECTRIC, INC.
    Department of DefenseNAICS 238210
    $13.8MSigned Sep 8, 2025
  • W912EF22C0002
    PICK ELECTRIC, INC.
    Department of DefenseNAICS 238210
    $13.8MSigned Jun 23, 2025

Contacts

Documents

No documents available.

Lifecycle

Solicitation:W9127N17R0031
  1. Pre-Solicitation
  2. Solicitation
  3. Awarded

This opportunity has been awarded.

  1. 5×
    Pre-SolicitationJun 28, 2017

    John Day SQ and SU Boards Replacement

    Notice dbf38325d73559c3da5dc7e5cb5bfeed on SAM.gov

  2. 2×
    SolicitationAug 18, 2017

    John Day SQ and SU Boards Replacement

    Notice 6119e88a22d04e2ba6616009b7459db8 on SAM.gov

  3. 2×
    AwardedCurrentNov 30, 2017

    John Day SQ and SU Boards Replacement

    Notice a15fb13a7ff245ff8a84e96a48f96042 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W9127N17R0031

Archive Date

Jan 17, 2020

Office Address