Notice ID: e51f38d8e6944f20b47650b151c6795dSpecial Notice
Rosemount Temperature Monitoring Equipment
Archived on September 14, 2023. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 3:00 PM UTC−07:00
- Posted
- August 15, 2023
- Notice type
- Special Notice
- NAICS
- 334513: Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- W071 ENDIST PORTLAND
- Place of performance
- Rufus, 97050
- Last updated
- Sep 25, 2026
Identifiers
- Solicitation number
- W9127N23Q0108
- Notice ID
- e51f38d8e6944f20b47650b151c6795d
Description
THIS IS A SPECIAL NOTICE PREPARED IN ACCORDANCE WITH FEDERAL ACQUISITION REGULATION (FAR) SUBPART 5.2 “SYNOPSES OF PROPOSED CONTRACT ACTIONS” NAICS 334513, Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables Response Deadline: 30 Aug 2023 The U.S. Army Corps of Engineers (USACE), Portland District (NWP) intends to negotiate/award a firm-fixed price (FFP) supply, single source procurement to Rosemount, Inc. for Rosemount temperature monitoring equipment to include Rosemount temperature sensors, Rosemount temperature transmitters, and Rosemount sensor and transmitter assembly to support John Day Lock and Dam. REASON FOR SOLE SOURCE ACQUISITION: The statutory authority for this non-competitive acquisition is FAR 13.106-1(b)(i), Soliciting from a single source for purchases not exceeding the simplified acquisition threshold. The purpose is to provide Rosemount temperature monitoring equipment to John Day Lock and Dam, to maintain authorization to discharge water into the Columbia River by remaining in compliance with the conditions of John Day’s NPDES (National Pollutant Discharge Elimination System) permit. Background: U.S. Army Corps of Engineers (USACE) Portland District project sites on the Columbia River use temperature monitoring system equipment to ensure compliance with the NPDES permit program. Heat load is a pollutant that is subject to a continuous monitoring requirement. Discharge temperature must be continuously monitored overtime and combined with the discharge flow rate. The permit defines continuous monitoring as collecting data once every 30 minutes and further requires that the temperature measurement be performed with a device of high accuracy. For John Day, the continuous temperature and flow monitoring requirements apply to the supply and discharge pipes of cooling water for main units 15 and 16, the discharge pipes of the powerhouse unwatering pumps 3 and 4, and the supply and discharge pipes of cooling water for the fan coil circuit breaker gallery cooling system in bay 15. The resulting monitoring system must provide a sufficiently accurate temperature measurement that is stored, it must calculate the required temperature, flow, and heat load metrics from the stored data, and it must provide the metrics data in the required format at regular intervals as required by the EPA. Justification: Rosemount Inc. is the only authorized vendor that can provide the necessary Rosemount temperature monitoring equipment needed to satisfy this requirement. Other manufacturers’ products do not meet the technical requirements to ensure successful continuous temperature monitoring. As the only authorized vendor, Rosemount Inc. is the only vendor able to provide OEM warranties and support for the required equipment. Impact: Failure to utilize Rosemount temperature monitoring equipment would result in an inability to measure discharge water temperature to the standard required by NPDES leading to penalties and potential litigation for failing to meet NPDES permit requirements and prevent the Corps in Engineers from legally discharging water resulting in lost electrical power generation and significant safety risk. The Government intends to solicit Rosemount, Inc. directly for these supplies on or around 30-AUG-2023. At this time, a solicitation does not exist. All responsible sources may submit a capability statement, proposal, or quotation, which shall be considered by the agency. *NO PHONE INQUIRIES, PLEASE. CAPABILITY STATEMENT SUBMISSION REQUIREMENTS (PLEASE REVIEW ALL BELOW) Point of Contact name, email address and phone number, CAGE code and SAM.gov Unique Entity ID number; In the event that the organization is a small business, please state the category of small business, such as 8(a), HUBZone, SDVOSB/VOSB, Women-Owned Small Business. Send responses, labeled as “W9127N23Q0108 – Rosemount Temperature Monitoring Equipment,” to the following: david.c.boone@usace.army.mil
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
No documents available.
Lifecycle
Solicitation:
W9127N23Q0108- Special NoticeCurrentAug 15, 2023
Rosemount Temperature Monitoring Equipment
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Handheld Monitoring Detector; Repost due to clarification of salient characteristics. - Only bids submitted through the solicitation will be accepted, please do not email them to the customer. Bids that do not meet the firm requirements listed in the description will not be accepted. This solicitation is posted as a brand name or equal. In the absence of a brand name listed in the solicitation, the salient physical function or performance characteristics must still be met. A completed Buy American form MUST be filled out and included with your bid to be considered. Offer submissions not including a completed attachment may be rejected as non-responsive. All Shipping/packaging/inspection charges to be included! A single shipment/invoice is requested. Multiple shipments must be approved in writing through the listed POC prior to shipping. | 65% | Combined Synopsis | 02/24/2026 |
CX300 Electronic Test Equipment | 61% | Combined Synopsis | 04/24/2026 |
Permanent GPS Base Station bundle and a prism with active and passive modes for tracking. Rugged batteries and a radio module and radio antennas. | 60% | Combined Synopsis | 09/17/2026 |
GPS Equipment | 60% | Combined Synopsis | 09/16/2026 |
This is a solicitation RFQ to purchase an xray fluorescent analyzer, meeting the same requirements as SciAps X-550 Pb HUD/EPA Lead Paint Analyzer | 59% | Combined Synopsis | 06/26/2026 |
Additional Details
Solicitation Number
W9127N23Q0108
Archive Date
Sep 14, 2023
Office Address
PORTLAND, OR, 97204-3495