Archived on October 1, 2024. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
2:00 PM UTC−07:00
Posted
August 29, 2024
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Agency
Department of WarDepartment of the Army

Notice details

Office
W071 ENDIST PORTLAND
Place of performance
Cascade Locks, OR, 97014
Last updated
Dec 4, 2025

Identifiers

Solicitation number
W9127N24Q0138
Notice ID
a01a48e84f444e009a0a6711a8472168

Description

U.S. Army Corps of Engineers (USACE) Bonneville Dam has nine escalators that are over 40 years old. Evaluations are needed to identify any faulty, worn, or defective parts and components along with estimated requirements to reestablish service on one escalator that is currently non-functioning. Contractor will provide assessment report with overall assessment and complete rehabilitation and replacement costs. Contractor will be required to partially disassemble to inspect internal mechanical and electrical components. The Contractor must furnish suitable equipment, tools, and labor to perform all work required to safely access all escalator components, evaluate, and make recommendations for rehabilitation or replacement at Bonneville Dam Powerhouse 2 and Vistor Orientation Building. The contractor must provide information that shows capability of performing detailed assessment of commercial escalators with at least 2 assessments of similar scope within the last 4 years. All testing and final assessment report must be completed within 10 weeks from award of contract unless otherwise notified by the government. The contractor must submit a schedule plan for on site evaluation of escalators which must incorporate arrival time, set up, clean up, and closing up of equipment at Bonneville Dam project. The contractor will be allowed to inspect and evaluate escalators at the Bonneville Site during normal working days from 7:00 am to 4:30 pm. Extensions to the daily time schedule may be allowable but must be submitted to the Government for approval at least 10 days in advance. An organized Site Visit is set. Additional information for attending is in the attached Combined Synopsis and Solicitation Package. DATE: 10 SEP 2024 TIME: 10:00 AM PST MEETING LOCATION: Bonneville Dam Security Office, HWY 84 exit 40, Cascade Locks, OR 97014

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

Solicitation:W9127N24Q0138
  1. Combined Synopsis
  1. 2×
    Combined SynopsisCurrentAug 29, 2024

    Escalator Assessment Bonneville Lock and Dam

    Notice a01a48e84f444e009a0a6711a8472168 on SAM.gov