GovChime
Notice ID: efdf09848777c1bc9e516761dcfa7aafSolicitation

43--Supply Air Compressor Units for Surge Tank Bubbler and Draft tube Depressing Air Systems Garrison Dam, Riverdale ND. Replacement Air Compressors for Draft Tube Depressing (2 each) and Surge Tank Bubbler (2 each) Air Systems.

Archived on September 28, 2013. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
7:00 AM UTC+02:00
Posted
September 13, 2013
Notice type
Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
333912: Air and Gas Compressor Manufacturing
Agency
Department of WarDepartment of the Army

Notice details

Office
W071 ENDIST OMAHA
Place of performance
USACE District, Omaha P.O. Box 527 Riverdale ND 58565 US
PSC
43: PUMPS AND COMPRESSORS
Last updated
Dec 5, 2025

Identifiers

Solicitation number
W9128F13T0125
Notice ID
efdf09848777c1bc9e516761dcfa7aaf

Description

Supply Air Compressor Units for Surge Tank Bubbler and Draft tube Depressing Air Systems Garrison Dam, Riverdale ND. Replacement Air Compressors for Draft Tube Depressing (2 each) and Surge Tank Bubbler (2 each) Air Systems. A. Draft Tube Water Depressing and Surge Tank Bubbler Air Compressors (4 total ). See attached specifications. Salient features are as follows: a. 460 V, 3 phase, 60 hertz NEMA premium efficiency motor rated at 100 horsepower or approved equal. b. Oil Free air meeting the requirements of ISO 8573-1 (2002) Class 0 c. Minimum capacity of 400 CFM at 115psi, maximum system pressure of 125 psig. d. Compressor unit shall operate with a power source of 460Volts, 3 phase, 60 cycle, from the adjacent motor control center (MCC 6A&B), Eaton Freedom 2100 with Eaton HMCP with Eaton C441 electronic motor protection. Replacement of conduit and/or conductors from MCC to new compressor units if necessary due to differences between old and new units shall be included. e. Microprocessor control, monitoring and alarm system with RS-232 Serial communications and Ethernet communication utilizing MODBUS and communication module for sequencing. Unit must have NEMA 4 enclosure for electrical/electronic components due to environment that compressors are housed. f. Air cooled with air cooled aftercooler if applicable. Ambient air rarely exceeds 70 degrees F but may drop to 20 degrees F with high humidity (50-95 %). Features of supplied compressor units must address this range via heaters and/or condensate control. g. Compressor Unit shall be equal to Atlas COPCO GA 75, Ingersoll-Rand IRN100H-OF, or Gardner-Denver Style ST100, Model EBP or other approved equal.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Rachelle Hairston, 402-995-2045 USACE District, Omaha

Documents

No documents available.

Lifecycle

Solicitation:W9128F13T0125
  1. Pre-Solicitation
  2. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. Pre-SolicitationSep 13, 2013

    43--Supply Air Compressor Units for Surge Tank Bubbler and Draft tube Depressing Air Systems Garrison Dam, Riverdale ND. Replacement Air Compressors for Draft Tube Depressing (2 each) and Surge Tank Bubbler (2 each) Air Systems.

    Notice 3d5b08d9a6909787774b1bc7635c4971 on SAM.gov

  2. SolicitationCurrentSep 13, 2013

    43--Supply Air Compressor Units for Surge Tank Bubbler and Draft tube Depressing Air Systems Garrison Dam, Riverdale ND. Replacement Air Compressors for Draft Tube Depressing (2 each) and Surge Tank Bubbler (2 each) Air Systems.

    Notice efdf09848777c1bc9e516761dcfa7aaf on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W9128F13T0125

Archive Date

Sep 28, 2013