Notice ID: 2c1613e4e97942a4bff5babbc406045cSolicitation
Gavins Point Spillway Gate Heater Redesign
Archived on September 26, 2020. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- Posted
- September 8, 2020
- Notice type
- Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 332313: Plate Work Manufacturing
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- W071 ENDIST OMAHA
- Place of performance
- NE, 68739
- Last updated
- Apr 29, 2026
Identifiers
- Solicitation number
- W9128F20Q0069
- Notice ID
- 2c1613e4e97942a4bff5babbc406045c
Description
Amendment 1 has been posted to Attachments. The purpose of this amendment is to provide a minor correction to the dimension of the cover plate outer radius on the bridging drawings sheet M-101. The bottom cover plate outer radius on sheet M-101 shall be revised to read (29'-3" R, not 29'-2 3/16" R), such that the centerline radius of the bullnose bolt holes (29' 2 - 15/32") and the back wall plate will align with dimensions on the bullnose section. The offer due date has not been extended. All other terms and conditions remain the same. ******************************************************************************************************************* This project consists of the entire work to furnish all supervision, labor, materials, off-site facility, qualified aluminum welders, and equipment to fabricate new spillway gate wall heater aluminum plates and hardware shown on the bridged drawings. Work shall be completed by trained and certified fabricators who have minimum of 2 years of experience in the aluminum fabrication and welding work. This work will be for a total of twenty eight (28) custom aluminum plates made in accordance to the specifications attached. Seven (7) back wall plates will be constructed as shown, along with seven (7) on the opposite hand for a total of fourteen (14) back wall plates. Seven (7) cover plates will be constructed as shown, along with seven (7) on the opposite hand for a total of fourteen (14) cover plates. Contractor will be responsible for transportation, loading / unloading of all furnished items to/from the Gavins Point Dam and contractors off-site facility. Contractor will not be involved in the installation Please see attached full solicitation for a more detailed Scope of Work, along with the Attachments for the bridging drawings and photos of the existing heater plates.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
No documents available.
Lifecycle
Solicitation:
W9128F20Q0069- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- SolicitationAug 11, 2020
Gavins Point Spillway Gate Heater Redesign
- Pre-SolicitationAug 11, 2020
Gavins Point Spillway Gate Heater Redesign
- SolicitationCurrentSep 8, 2020
Gavins Point Spillway Gate Heater Redesign
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
W9128F20Q0069
Archive Date
Sep 26, 2020
Office Address
OMAHA, NE, 68102-4901