GovChime
Notice ID: 3d7009800ca3e8d4322f58d4a99203c9Solicitation

25--Installation of Liftgates and Tow Hitches

Archived on May 14, 2011. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
7:00 AM UTC+02:00
Posted
May 4, 2011
Notice type
Solicitation
Set-aside
Women-Owned Small Business
NAICS
238290: Other Building Equipment Contractors
Agency
Department of WarDepartment of the Army

Notice details

Office
0413 AQ HQ RCO-HI
Place of performance
US EXPEDITIONARY CONTRACTING COMMAND PACIFIC 413TH CONTRACTING SUPPORT BRIGADE ATTN: BLDG 692 MCCORNACK ROAD-BASEMENT SCHOFIELD BARRACKS HI 96857-5000 US
PSC
25: VEHICULAR EQUIPMENT COMPONENTS
Last updated
Dec 5, 2025

Identifiers

Solicitation number
W912CN11T0188
Notice ID
3d7009800ca3e8d4322f58d4a99203c9

Description

Interested offerors are required to download the solicitation and any subsequent amendments from the website. Once posted on the website, interested offerors are responsible for monitoring the website until the closing date for any issued amendments or changes. This is a new requirement. No previous procurement history is available. Offeror shall furnish equipment, tools, supplies, labor, transportation, and materials necessary to install Five (5) liftgates and tow hitches on DPW utility vehicles, at Schofield Barracks, Island of Oahu, Hawaii. Install liftgates and tow hitches to manufacturer's specifications. 1.1. Liftgate Specifications. Liftgate shall be 1,000# capacity. Return all automotive parts taken off the utility vehicles back to the Government. 1.2. Install remote pendent control in addition to the standard fixed control. Outside mount liftgates are required. Government Vehicles are as follows: 0001AA: 2009 Chevrolet, 2500 HD with Service Body- liftgate type, original series cable type #54-1040 F11 TP, 1000lb capacity, Gate width 52" x 38" 0001AB: 2006 Chevrolet, 2500 HD with Service Body- liftgate type, original series cable type #54-1040 F11 TP, 1000lb capacity, Gate width 52" x 38" 0001AC: 2010 Ford, 250 with Service Body- liftgate type, original series cable type #54-1040 F11 TP, 1000lb capacity, Gate width 52" x 38" 0001AD: 2008 Chevrolet, Express Van- Only Cable Type liftgate available for Vans, 1000 lb capacity, 63" x 38" 0001AE: 2010 Ford, E-350 Van- Only Cable Type liftgate available for Vans, 1000 lb capacity, 63" x 38" FEWR: RP001110J

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Marlene G. Barretto, 808-655-3044 RCO Hawaii (PARC Pacific, 413th CSB)

Documents

No documents available.

Lifecycle

Solicitation:W912CN11T0188
  1. Pre-Solicitation
  2. Solicitation

Award typically follows within 30–90 days after the response deadline. (estimate)

  1. 3×
    Pre-SolicitationApr 19, 2011

    25--Installation of Liftgates and Tow Hitches

    Notice 5525bf62c9b6030482b6bdddc8c534e4 on SAM.gov

  2. SolicitationCurrentMay 4, 2011

    25--Installation of Liftgates and Tow Hitches

    Notice 3d7009800ca3e8d4322f58d4a99203c9 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
The U.S. Army Corps of Engineers - New England District is issuing a Solicitation Notice for Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT. THE WORK CONSISTS OF: The Contractor shall furnish all necessary materials, equipment, and labor required to construct and commission a new power system for the Dike B Operator unit. The scope of work involves comprehensive site preparation to support the construction of a reinforced concrete generator pad and the installation of secure perimeter fencing. The Contractor is responsible for the procurement and installation of a standalone, propane-powered generator and a corresponding propane fuel storage tanks. Following the physical installation, the Contractor shall execute all final electrical connections and integration into the existing sluice gate operator unit and control panel. All work shall comply with all applicable federal laws and codes, and shall be completed in accordance with the Statement of Work. This procurement is set-aside for small business vendors. The applicable NAICS code is 238290 with a Small Business Size Standard of $22 Million. ALL VENDORS MUST HAVE AN ACTIVE REGISTRATION IN SAM.GOV AT THE TIME OF SUBMISSION IN ORDER TO BE CONSIDERED. ANY VENDOR THAT DOES NOT HAVE AN ACTIVE SAM.GOV REGISTRATION WILL BE REJECTED AS NON RESPONSIVE.
55%
Solicitation11/18/2026
As of 18 August 2026: Amendment 0001 posted to respond to contractor RFis. The New York District Army Corps of Engineers intends to award a contract for a Request for Proposal for the Design and Installation of 3M Fall Protection Systems Davit Arm and Detent Anchors at AFO. The Project has four main requirements:(a) Engineering Assessment and Design The contractor will be required to evaluate the required installation sites for fall protection equipment and develop a Design Document to appropriately install the equipment.(b) Install Government Furnished Equipment (GFE) The Government will provide the fall protection equipment to be installed. The contractor will provide 3M certified installers and install the equipment per the design.(c) Testing and Inspection The contractor will test and inspect all installed equipment to ensure it will function as intended.(d) End User Training The contractor will provide a training session for AFO employees that will use and maintain the equipment. Offerors should be regularly engaged in the business of installing fall protection systems and be able to provide 3M Certified Installers.
52%
Solicitation08/31/2026
Sound Proofing installation in Building 19 Room B125.
51%
Combined Synopsis08/13/2026
The U.S. Army Corps of Engineers, New England District is issuing this Sources Sought Announcement for Construction Services for the replacing the wire ropes and designated associated sheave blocks for the number 1 service gate of the dam at the Franklin Falls Dam in Franklin NH. This announcement is to determine interest, availability and capability of 8(a), HUBZone, Service-Disabled Veteran-Owned, Women-Owned and Small Business concerns for this project. The NAICS code for this procurement is 237990 with a size standard of $22M. The project is planned to be solicited in the Spring of 2027 with construction to begin place in the Spring/Summer of 2027. The estimated construction cost is between $350,000 - $500,000. The project site is the inlet culvert on the lake side of the Franklin Falls Dam in Franklin, NH. Work for this project will likely include, but not be limited to, the following: Replace the existing stainless steel wire ropes that operate the number 1 service gate. Wire ropes must meet the following conditions: Meet US Steel Manufacture Requirements. Shall be 1,085 linear feet of 1” X 6X26 GALV XIP IWRC RRL PLAIN ENDS. The wire rope shall have a minimum breaking strength of 100 tons. The wire rope shall be lubed during the time of manufacture with accepted lubrication. Specification sections 35 01 70.13 and 35 20 16.53 will be included in the solicitation. Wire rope clips and thimbles will be designed by the contractor for this project and must fully conform with ASME B30 standards and proper amount of clips shall be provided for wire rope size and requirements for proper wire rope turnback. Remove and replace the lower sheave block assembly (five total) that is associated with the number 1 service gate. The following will be applicable for these assemblies: Sheave pins and bushings. Site plates, hitch plates, keeper plates Tap bolts, pipe separator and bolts Hitch pins Finishes and paint Contractors shall install the wire ropes and lower sheave blocks according to appropriate industry standards for Load Handling Equipment of this type and configuration. Interested firms should submit a capabilities package to include the following: business classification (i.e. HUBZone, small business, etc.), as well as qualifications and experience in performing the work components stated above. Please include at least two specific examples of the firm’s experience performing the work requirements stated above. The projects must have been performed within the last seven years. Please indicate the team subcontractor(s) (if any), including their prior experience and qualifications, which will be used to support the offeror’s effort, and their experience must also have been performed within the last seven years. Proof of bonding capability is required. Responses are limited to twenty pages. Responses are due by 25 November 2026 at 1:00 PM Eastern. Responses should be emailed to: Distephano Marcellus – Distephano.Marcellus@usace.army.mil Phone Contact: (978) 318-8890 Interested firms shall provide the above documentation in one original form and one copy. The Government will not pay for any material provided in response to this market survey nor return the data provided. This notice is for information purposes only and is not a request to be placed on a solicitation mailing list nor is it a Request for Proposal (RFP) or an announcement of a solicitation. The results of this survey will be considered to be in effect for a period of one year from the date of this notice. Government Agency URL: www.nae.usace.army.mil Government Agency URL Description: New England District, Corps of Engineers
45%
Market Research11/25/2026
This acquisition is for a a non-personal services contract to provide facility maintenance services and certain related facility management services at Fort Hood to include operation, preventative maintenance (PM) and corrective maintenance (CM) service (M and S) for approximately 136 automatic doors, 3,375 overhead doors (some hangers), and commercial doors for preventative and corrective (on demand) maintenance at the Fort Hood Army Installation, Fort Hood, Texas. This requirement also includes certain facility management and support services, as defined in this PWS, at US Army Garrison Fort Hood. The Contractor shall provide required PM and (CM) services in compliance with all code; criteria; regulations; and Federal, State, and local laws. All work shall be performed at Fort Hood, Texas, which consists of the Main Cantonment, West Fort Hood, and all areas under the control of Fort Hoods Installation or Installation considered Real Property. AMENDMENT 1: The purpose of amendment 1 is to incorporate site visit information detail. Location: FT Hood, TX. Date: 6 August 2026 Time: 1:30 PM CST. Attachments enclosed. AMENDMENT 2: Extend proposal due date to 14 August 2026, 1:00 PM CST (Posted to GPE/Sam.gov on 7 Aug 2026). AMENDMENT 3: The purpose of amendment 3 is to incorporate revised documents. Please see the updated Solicitation Amendment 3 for details. AMENDMENT 4: The purpose of amendment 4 is to communicate revisions to the evaluation factors detailed in RFO 52.212-2, Evaluation-Commercial Products and Commercial Services. (Deviation 2026-O0038). Please see updated solicitation attachment: Solicitation Amendment 4_W912DY26RA0760001_12 Aug.
45%
AwardedOpen

Additional Details

Solicitation Number

W912CN11T0188

Archive Date

May 14, 2011