GovChime
Notice ID: 2f6684c78c344f04bff2faa23d312fd4Sources SoughtArchived

READINESS CENTER ADDITION COMMISSIONING SERVICES

Archived on May 1, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
11:00 AM HST
Posted
March 26, 2025
Notice type
Sources Sought
NAICS
541310: Architectural Services
Agency
Department of WarDepartment of the Army

Notice details

Office
W7M4 USPFO ACTIVITY HI ARNG
Place of performance
Kapolei, HI, 96707
Last updated
Nov 15, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W912J6-25-Q-15SH
Notice ID
2f6684c78c344f04bff2faa23d312fd4

Description

This announcement is a Sources Sought (market research) Notice. This is not a Request for Quote (RFQ) or Request for Proposal (RFP). This announcement is for information and planning purposes only and is not to be taken as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. The Hawaii National Guard has a requirement for building commissioning for the following systems: HVAC components and equipment, HVAC systems, Building Automation System, Lighting control system, domestic hot water system, electrical system (interaction of emergency power, UPS, life safety systems), and photo voltaic system. The tentative period of performance for this acquisition is 1 December 2024 to 31 May 2026. The purpose of this sources sought notice is to determine interest and capability of potential qualified firms relative to the North American Industry Classification (NAICS) code 541310 (Architectural Services) and the applicable size standard is $12.5M. 5.0 Requirements: The contractor shall provide the necessary personnel, labor, materials, supplies, and equipment as indicated below to perform the tasks outlined: 5.1 Commissioning Services. The contractor shall perform the following: 5.1.1 Conduct building commissioning for the following systems: HVAC components and equipment, HVAC systems, Building Automation System, Lighting control system, domestic hot water system, electrical system (interaction of emergency power, UPS, life safety systems) 5.1.2 Develop a Commissioning Plan describing commissioning process, commissioning team and commissioning schedule. 5.1.3 Review construction documents including commissioning specifications, plans, and basis of design. 5.1.4 Review submittals for building and photo voltaic systems, including but not limited to HVAC, plumbing, electrical and fire protection systems. 5.1.5 Attend construction progress meetings, conduct site observations, and attend pre-installation meetings for eight months twice per month. 5.1.6 Develop systems pre-functional checklists. 5.1.7 Develop specific equipment and system functional performance test procedures. 5.1.8 Review Operations and Maintenance data. 5.1.9 Witness equipment startups. 5.1.10 Witness/conduct functional performance tests. 5.1.11 Coordinate training sessions. 5.1.12 Provide a written report regarding the results of the commissioning process. 5.1.13 Complete LEED Fundamental Commissioning pre-requisite template and provide supporting documentation. SUBMISSION REQUIREMENT FOR RESPONSES TO THIS SOURCES SOUGHT NOTICE: 1) Your intent to submit a quote for this requirement when it is formally advertised; 2) Name of firm with address, phone number, e-mail address, and point of contact 3) Cage code and Unique Entity ID#; 4) Size of firm including category of small business, such as 8(a), Women-Owned Small Business (WOSB), HUBZone, Small Disadvantaged Veteran Owned Small Business (SDVOSB); and 5) Statement of Capability stating your skills, experience, and knowledge required to perform the specific type of work. Firms responding to this sources sought notice, who fail to provide all of the required information requested, will not be used to assist the Government in the acquisition decision. This announcement is a Sources Sought (market research) Notice. This is not a Request for Quote (RFQ) or Request for Proposal (RFP). This announcement is for information and planning purposes only and is not to be taken as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. NOTE: IF YOU DO NOT INTEND TO SUBMIT A QUOTE FOR THIS REQUIREMENT WHEN IT IS FORMALLY ADVERTISED, PLEASE DO NOT SUBMIT A RESPONSE TO THIS SOURCES SOUGHT NOTICE.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Documents

No documents available.

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    READINESS CENTER ADDITION COMMISSIONING SERVICES

    Notice 2f6684c78c344f04bff2faa23d312fd4 on SAM.gov

  2. 6
    Version 6Combined Synopsis/SolicitationArchived

    Type changed from Sources Sought to Combined Synopsis/Solicitation

    READINESS CENTER ADDITION COMMISSIONING SERVICES

    Notice bfb3acffedf443f385bd2b31358593f6 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W912J6-25-Q-15SH

Archive Date

May 1, 2025

Office Address

HONOLULU, HI, 96816-4495