GovChime
Notice ID: 3fa39b077e484161a17dc90f7b1e2274Sources SoughtArchived

Kentucky Lock Lift Pump Station Repair/Replacement

Archived on January 13, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM CST
Posted
December 15, 2025
Notice type
Sources Sought
Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS
238210: Electrical Contractors and Other Wiring Installation Contractors
Agency
Department of WarDepartment of the Army

Notice details

Office
US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION GREAT LAKES AND OHIO.ENDIST NASHVILLE.W072 ENDIST NASHVILLE
Place of performance
Grand Rivers, Kentucky
Last updated
Nov 5, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W912P5-26-Q-KLSR
Notice ID
3fa39b077e484161a17dc90f7b1e2274

Description

Request for Information: The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.

This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.

Requirement: Contractor shall furnish all materials, supplies, tools, equipment, transportation, supervision, quality control, and labor necessary to complete this Scope of Work.  All materials and workmanship will be manufactured and accomplished according to industry standards and specifications. For additional information, reference the attached document, “Lock Wall Lift Station Pump Repairs Reference Document”.

  1. Two (2) new pumps, 40 GPM and 108 feet TDH, 5.0 HP, 3450 RPM, 460/3/60 Hz will be procured and installed within the Lock Wall lift station. The existing pump supports within the lift station are damaged and new pump supports will need to be installed. The contractor shall also verify if the Conery base can be reused without modification. If not, the contractor will be responsible for replacing the base. Costs estimated for this work shall include any pumping/removal of existing waste in the lift station that is required to complete this task safely. Reference the provided reference document for additional details related to existing utilities associated with the lift station.
  2. The existing lift station contains two (2) grinder pumps. One of the existing pumps has been removed and replaced. The removed pump shall be repaired to full functionality. The removed pump is a Zoeller Model G7112, 7.5 HP, 3450 RPM, 460/3/60 Hz, submersible high head grinder pump complete with 2 ½ inch horizontal discharge flange that is adaptable to 3-inch, SC/SC lower seal, 7.125-inch diameter impeller complete with 25-feet power & control cable.
  3. The contractor shall repair or replace the transducer associated with the lift station pump. The currently installed transducer is precision digital PDA6420 Split Core AC Current Transducer.
  4. The contractor shall replace “in-kind” the 2” check valve inside the wet well. The existing check valve is Flomatic Check Valves Model 508 Part Number 3235.
  5. The contractor shall replace “in-kind” the 2” ball valve inside the wet well. The existing ball valve is Flomatic Ball Valves Part Number SSBV1000-20. Verify operation of the new ball valve with the extension handle.
  6. The Contractor shall perform a functionality test to ensure the system works as intended. Test procedures describing the functionality test shall be submitted to the Government for review and approval. The following functions shall be tested to verify that they are functioning as intended by design:
    • Both pumps automatically run via the transducer system.
    • Both pumps automatically run via the float system.
    • The pumps automatically switch from the transducer system to the float system if the transducer system fails.

Period of Performance: The Period of Performance shall be performed within 30 calendar days of the award date.

Place of Performance:  

Kentucky Lock Resident Office

193 Taylor Park Rd.

Grand Rivers, KY 42045

NAICS: The anticipated NAICS code for this requirement is 238210 (Electrical Contractors and Other Wiring Installation Contractors) with a size standard of $19,000,000.

Survey: Please send responses to the Market Survey to Samantha Clay at Samantha.J.Clay@usace.army.mil  and Cierra Vega at Cierra.R.Vega@usace.army.mil by 12:00PM CT on December 29, 2025.

  1. Name of Firm:
  2. CAGE:
  3. Point of Contact (include email address)
  4. Are you classified as a small business under any of the following NAICS code:
  • 238210 (Electrical Contractors and Other Wiring Installation Contractors)

      5. If this requirement is advertised, do you anticipate submitting a quote?

      6. List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience with electrical and wiring installation:

  • Project Name / General Description:

           Contract Number (if applicable):

           Dollar Amount:

  • Project Name / General Description:

           Contract Number (if applicable):

           Dollar Amount:

  • Project Name / General Description:

           Contract Number (if applicable):

           Dollar Amount:

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

No documents available.

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    Kentucky Lock Lift Pump Station Repair/Replacement

    Notice 3fa39b077e484161a17dc90f7b1e2274 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
Title: LLA Navigation Lock Switchgear Replacement: The work is located at the Lower Granite Dam, Pomeroy, Washington. The solicitation will be issued as a Best Value Trade-Off (BVTO) Request for Proposal (RFP) and result in a single firm-fixed price construction contract. This procurement is a small business set aside. 100% Performance and payment bonds will be required for this project. The North American Industry Classification System (NAICS code for this project is 238210 Electrical Contractors and Other Wiring Installation Contractors and the associated small business size standard is $19 million. Solicitation number W912EF27RA002 will be posted to the SAM.gov Contract Opportunities website on or about mid November 2026. The proposal due date will be contained in the solicitation and any solicitation amendments that may be issued. The solicitation will be made available for download on the SAM.gov Contract Opportunities website. Offerors are responsible for checking the referenced page for any updates to the Notice. The Government is not responsible for any loss of Internet connectivity or for an offeror's inability to access the documents posted at the referenced website. Proposals will be due approximately 30 days after the solicitation is posted. The exact proposal due date will be indicated in the solicitation. System for Award Management (SAM): Offerors must register in the SAM at https://sam.gov/content/home prior to receiving an award. NOTE: The response date that is required to post this notice is not in any way a due date for any submission. This is a pre-solicitation notice only. Scope: The scope of the work involves replacing existing medium and low voltage switchgear lineups and their associated feeder cables with modernized medium and low voltage switchgear and motor control center lineups at Lower Granite Dam Navigation Lock. The main features of work includes: Provide and install one (1) new medium voltage switch gear. Provide and install one (1) new low voltage switch gear. Provide and install two (2) new motor control center lineups. Provide modernized controls for existing electrical loads. Provide one (1) new 4,160/480-V 1,000 kVA transformer. Provide lighting load centers to replace existing panels. Provide new concrete housekeeping pads for new electrical equipment. Provide new cable trays and conduits where required by circuit reconfigurations and to bring fill ratios to levels that meet electrical codes. Provide an HMI screen to replace an existing annunciator panel. Demolish existing medium and low voltage switchgear, motor controls centers, and transformers. Demolish the existing 480VAC feeders routed from existing low voltage switchgear and motor control centers. Seal hatch and any expansion joints, or cracks, to prevent water intrusion in an existing electrical room. This work is anticipated to be performed in 2028 and 2029, with cutover power construction work being completed during the 2028 and 2029 navigation lock outages. Access to the navigation lock deck and electrical substation rooms will be available for workers and equipment. THE GOVERNMENT RESERVES THE RIGHT TO CANCEL THE SOLICITATION EITHER BEFORE OR AFTER THE CLOSING DATE. NO REIMBURSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING INFORMATION IN RESPONSE TO THIS PRE-SOLICITATION NOTICE OR ANY FOLLOW-UP INFORMATION REQUEST. All on-site work shall be performed in accordance with the Corps of Engineers Safety and Health Requirements Manual (EM 385-1-1). Establish and manage an effective on-site Safety and Health program in accordance with EM 385-1-1 that will require the development and submission of a comprehensive project specific Accident Prevention Plan for Government acceptance. In addition, develop and submit for Government acceptance Activity Hazard Analyses for each phase of work and a project specific Fall Protection Plan that comply with EM 385-1-1. A Site Safety and Health Officer (SSHO) employed by the prime contractor is required for each shift of the contractor's on-site operations. The SSHO shall possess a minimum of 5-years’ experience in construction safety on similar projects, shall have completed the 30-Hour OSHA Construction Safety training within the last 5 years, and shall have completed at least 24 hours of safety training from accredited safety training sources each year for the past 5 years. Establish and manage an effective Contractor Quality Control (CQC) System that will require the development and submission of a comprehensive project specific CQC Plan for Government acceptance. A CQC System Manager employed by the prime contractor is required to be on-site for each shift of the Contractor's operations. The CQC System Manager must possess a minimum of 5 years relevant experience in a supervisory or management position such as Quality Control Manager, Quality Assurance Manager, or Construction Manager directly involved in the management of construction quality at the project site. In addition, the CQC System Manager shall have completed the course entitled “Construction Quality Management for Contractors” within the last 5 years. Use the Government-furnished Resident Management System (RMS) – Contractor Mode to record, maintain, and submit various information throughout the contract period. RMS is a Windows-based program capable of operating on a stand-alone personal computer or on a network. The Government will make the quality control system (QCS) software available to the Contractor at time of notice to proceed. The project involves the development and management of Contractor furnished submittals for items such as pre-construction plans, product data, test reports, and contract close-out documentation as required by the technical specifications of the contract. Miscellaneous work within the project includes the delivery of As-Built Drawings, O&M Manuals, Contractor- Prepared Shop Drawings, and spare parts to the customer. Solicitation Number W912EF27RA002 will be posted to the SAM.gov approximately on around mid to late November 2026. The solicitation is a Request for Proposal Important Note: The SAM.gov Contract Opportunities Response Date listed elsewhere in this synopsis is for SAM.gov archive purposes only. It does not necessarily reflect the actual proposal due date. There is no response date included in this notice. The proposal due date and time will be contained in the solicitation and any solicitation amendments that are issued. Anticipated Award date is early to mid-March 2027. A site visit will be offered approximately 2 weeks after the solicitation is made available to offerors. See solicitation for details about the site visit. ACCESS FOR FOREIGN NATIONALS: Security clearance for foreign nationals to attend a site visit requires approximately 4 weeks; therefore, clearance should be requested immediately. To request clearance, please submit the names of all foreign nationals proposed for site visit attendance, along with documentation to verify that he/she was legally admitted into the United States and has authority to work and/or go to school in the US. Such documentation may include a US passport, Certificate of US citizenship (INS Form N-560 or N-561), Certificate of Naturalization (INS Form N-550 or N-570), foreign passport with 1-551 stamp or attached INS Form 1-94 indicating employment authorization, Alien Registration Receipt Card with photograph (INS Form 1-151 or 1-551), Temporary Resident Card (INS Form 1-688}, Employment Authorization Card (INS Form l-688A}, Reentry Permit (INS Form 1-327}, Refugee Travel Document (INS Form 1-571}, Employment Authorization Document issued by the INS which contains a photograph (INS Form I-688B}. Send this information by email to leanne.r.walling@usace.army.mil and jani.c.long@usace.army.mil Foreign nationals must have received clearance prior to being granted access to the project site.
76%
Pre-Solicitation11/13/2026
TENKILLER 15KV SWITCHGEAR AND STATION SERVICE REPLACEMENT *PLEASE NOTE: The previous industry notices for this project are as follows: W912BV26SS04 was the Sources Sought posting for Market Research. W912BV26RA032 was the previous solicitation number posted with the Pre-Solicitation Notice. The solicitation number has been updated to W912BV27RA003.
62%
Solicitation12/03/2026
This solicitation is for the contractor to furnish all personnel, equipment, supplies and materials necessary to install (16) security lights AND (8) utility poles and power supply for Green River Lock and Dam#1, located at 5026 Dam Road, Reed, KY 42451. All work shall be performed in strict compliance with the attached scope of work and all other terms, clauses, and conditions incorporated herein. Quotes are due on 10 August 2026 at 1:00 PM Eastern Time. NOTE: THIS RFQ IS 100% SET ASIDE FOR SMALL BUSINESS. The NAICS code for this procurement is 238210. The size standard is $19M. The solicitation will be available on the web only. Telephone and Fax requests for this solicitation will not be honored. Project files are Portable Document Format (PDF) files and can view, navigated, or printed using Adobe Acrobat Reader. To download the solicitation for this project, contractors are required to register at the Federal Business Opportunities. Amendments will be available from the beta.sam.gov website by download only. Prior to submission of quotes all contractors must have an active registration in the System for Award Management (SAM) database. To register or update information go to http://www.SAM.gov. Questions may be addressed to ProjNet. This announcement serves as the advance notice.
61%
Solicitation08/10/2026
This is a solicitation notice for a total small business set aside design build Request for Proposal (RFP) to install power on the southeast of Hangar 1 to accommodate the Black Hawk Aircrew Trainer (BAT) and the Transportable Flight Procedure Simulator (TFPS) including the ECU units for each device. Electrical requirements for each device are: two 120/208v, 200 amp, 60Hz, three phase, 4 wire plus ground services with MS980555C52412S or MS90555C52143S receptacles. The project will connect Simulators to the Fire Alarm System, converting bay areas to a wet pipe sprinkler system, and correct egress deficiencies and other life safety repairs needed to ensure life safety including code required egress/emergency lighting and the like. Finally, the project will also install expanded metal mesh in a prefab arms vault that was installed in the structural repair project (FTW433) to be in compliance with AR190-11 Tab G to be used as an Arms Room. Updates to the existing fire system to meet current building codes may be required. This building has been identified as a historical building. Coordination with the SHPO will be required to ensure project will not violate any laws or regulations. The construction cost limitation for this requirement is $18,000,000. The performance period will be approximately 600 calendar days.
61%
Solicitation06/25/2026
Forest Service Fernan Ranger Station lift station electrical repairs in accordance with the statement of work. Solicitation number 1240LU26Q0125 is issued as a request for quotation (RFQ). The magnitude of the project is under $25,000.
59%
Combined Synopsis11/19/2026

Additional Details

Solicitation Number

W912P5-26-Q-KLSR

Archive Date

Jan 13, 2026

Office Address

NASHVILLE, TN, 37203-1070