GovChime
Notice ID: c0519d714d0d400190dc30b32780645aSources SoughtArchived

Kentucky Lock Lift Pump Station Repair/Replacement

Archived on November 7, 2025. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
12:00 PM CDT
Posted
October 16, 2025
Notice type
Sources Sought
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Agency
Department of WarDepartment of the Army

Notice details

Office
US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION GREAT LAKES AND OHIO.W072 ENDIST NASHVILLE
Place of performance
Grand Rivers, Kentucky, 42045
Last updated
Nov 7, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W912P5-26-Q-KYLS
Notice ID
c0519d714d0d400190dc30b32780645a

Description

Request for Information: The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.

This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.

Requirement: Contractor shall furnish all materials, supplies, tools, equipment, transportation, supervision, quality control, and labor necessary to complete this Scope of Work, at the areas specified at Kentucky Lock and Dam, located in Livingston County Kentucky. All materials and workmanship will be manufactured and accomplished according to industry standards and specifications.

  1. The existing lift station contains two (2) grinder pumps. One of the existing pumps has been removed and replaced. The removed pump shall be repaired to full functionality. The removed pump is a Zoeller Model G7112, 7.5 HP, 3450 RPM, 460/3/60 Hz, submersible high head grinder pump complete with 2 ½ inch horizontal discharge flange that is adaptable to 3-inch, SC/SC lower seal, 7.125-inch diameter impeller complete with 25-feet power & control cable.
  2. The contractor shall repair or replace the transducer associated with the lift station pump. The currently installed transducer is precision digital PDA6420 Split Core AC Current Transducer.
  3. Correct the alignment of the pump 2 outlet with the pump 2 sewage pipe inlet. Currently, the items are misaligned, and a gap exists on one side of the connection. Costs estimated for this work shall include any pumping/removal of existing waste in the lift station that is required to complete this task safely. Reference the provided reference document for additional details related to existing utilities associated with the lift station.
  4. The Contractor shall perform a functionality test to ensure the following functions work as intended by design:
    • Both pumps automatically run via the transducer system.
    • Both pumps automatically run via the float system.
    • The pumps automatically switch from the transducer system to the float system if the transducer system fails.
       

Period of Performance: The Period of Performance shall be performed within 30 calendar days of the award date.

Place of Performance:   Kentucky Lock Resident Office

                                         193 Taylor Park Rd.

                                         Grand Rivers, KY 42045

NAICS: The anticipated NAICS code for this requirement is 238210 (Electrical Contractors and Other Wiring Installation Contractors) with a size standard of $19,000,000.

Survey: Please send responses to the Market Survey to Samantha Clay at Samantha.J.Clay@usace.army.mil by 12:00PM CT on October 23, 2025.

  1. Name of Firm:
  2. CAGE:
  3. Point of Contact (include email address)
  4. Are you classified as a small business under any of the following NAICS code:
  • 238210 (Electrical Contractors and Other Wiring Installation Contractors)

       5. If this requirement is advertised, do you anticipate submitting a quote?

       6. List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience with electrical  and wiring installation:

1. Project Name / General Description:

Contract Number (if applicable):

Dollar Amount:

2. Project Name / General Description:

Contract Number (if applicable):

Dollar Amount:

3. Project Name / General Description:

Contract Number (if applicable):

Dollar Amount:

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Primary Contact

Secondary Contact

Documents

No documents available.

Lifecycle

  1. 3
    Version 3Sources SoughtArchivedCurrent

    Kentucky Lock Lift Pump Station Repair/Replacement

    Notice c0519d714d0d400190dc30b32780645a on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W912P5-26-Q-KYLS

Archive Date

Nov 7, 2025

Office Address

NASHVILLE, TN, 37203-1070