Notice ID: bce8d08ac1744b5ebcf15cb3c6ebcd87Solicitation
Playgrounds and Climbing structures inspections USAG Bavaria
Archived on January 14, 2025. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 11:00 AM UTC+01:00
- Posted
- December 18, 2024
- Notice type
- Solicitation
- NAICS
- 541350: Building Inspection Services
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- 0409 AQ HQ CONTRACT
- Place of performance
- DE-BY, 92676
- Last updated
- Jan 23, 2026
Identifiers
- Solicitation number
- W912PB25R3008
- Notice ID
- bce8d08ac1744b5ebcf15cb3c6ebcd87
Description
Amendment P0001 posted. The purpose of this amendment is: a. Extend Solicitation Due Date until 30 December 2024; 11:00 AM, b. Answer questions from vendors. c. All other terms and conditions of the Solicitation remain the same. 409th Contracting Command, 928th Contracting Battalion (CBN) / Regional Contracting Office Bavaria (RCO) issues a solicitation for the procurement of services for Playgrounds and Climbing Structures Inspections within the United States Army Garrison (USAG) Bavaria, Germany. A firm fixed price (FFP) Requirements Type Contract will be awarded. This requirement will utilize low price technically acceptable evaluation factors in determining the successful offer. All amendments to the solicitation will be posted to this website. All documentation can and must be downloaded from the website. All contractors must be registered in the System for Award Management (SAM at www.sam.gov) to be eligible for contract award. All dates are subject to change without notice. The Government will not exercise any supervision or control over the contract service providers. The Contractor shall perform to the standards specified in the Performance Work Statement (PWS). The PWS and all associated documentation are provided with this solicitation. The Period of Performance is expected to start 15 January 2024 and includes a one (1) year Base Period with two (2) one-year Option Periods IAW FAR Clause 52.217-9 (Option to Extend the Term of the Contract). FIRMS INTERESTED IN SUBMITTING PROPOSALS MUST: complete the entire solicitation document, to include representations and certifications, provisions and clauses, provide all product technical specification documentation and technical compliance certifications, and ensure current registration in the SAM system at https://www.sam.gov. Any questions MUST BE EMAILED to: Anastasia.n.caldera.civ@army.mil Please pay close attention to the deadline for submitting questions and requesting a site visit. The Government reserves the right to delay or cancel the solicitation at any time prior to award.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Documents
Select documents to download
Showing 6 of 6 items
Document | Source | Agency | Posted Date | File Size | Actions | |
|---|---|---|---|---|---|---|
| Presolicitation | DEPT OF THE ARMY | Dec 18, 2024 | - | |||
| Solicitation | DEPT OF THE ARMY | Dec 18, 2024 | - | |||
| Solicitation | DEPT OF THE ARMY | Dec 18, 2024 | - | |||
| Solicitation | DEPT OF THE ARMY | Dec 18, 2024 | - | |||
| Solicitation | DEPT OF THE ARMY | Dec 18, 2024 | - | |||
| Solicitation | DEPT OF THE ARMY | Dec 18, 2024 | - |
Lifecycle
Solicitation:
W912PB25R3008- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- 2×Pre-SolicitationOct 29, 2024
Playgrounds and Climbing structures inspections USAG Bavaria
- 3×SolicitationCurrentNov 26, 2024
Playgrounds and Climbing structures inspections USAG Bavaria
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Pallet Rack Inspection and Repair Services See attached RFI document for details. | 64% | Market Research | 11/20/2026 |
Elevator Inspection Services at James J. Peters VA Medical Center | 64% | Market Research | 10/23/2026 |
a. The purpose of this amendment is to extend the response deadline to November 17, 2026, at 4:00 p.m. | 61% | Combined Synopsis | 11/17/2026 |
Please note this solicitation is not ready to be issued as of this date. The Embassy of the United States in Singapore intends to release the solicitation on the SAM.gov website when it becomes available. The U.S. Embassy Singapore intends to issue a Request for Quotations (RFQ) for independent residential apartment condition inspection and reporting services at Embassy-leased residential properties in Singapore. The Government anticipates awarding an Indefinite-Delivery, Indefinite-Quantity (IDIQ) contract under which services will be ordered through individual task orders on an as-needed basis. Services are anticipated to include comprehensive visual and functional inspections of residential apartments following landlord rectification and renovation works; identification and documentation of defects and deficiencies; high-resolution photographic records; and preparation of detailed condition reports. The Embassy manages approximately 120 residential apartments, generally ranging from 1,200 to 3,600 square feet. This portfolio size does not represent a guaranteed quantity of inspections. The anticipated contract performance period is one year, with no option periods. The Government may award the contract based on the initial quotation without conducting discussions. Contractors shall comply with the System for Award Management (SAM) registration requirements applicable to this acquisition, as specified in the solicitation and FAR 52.204-7. Contractors shall obtain all licenses, permits, registrations, and authorizations required to perform work in Singapore in accordance with DOSAR 652.242-73, Authorization and Performance. Offerors are advised that contract performance in Singapore may subject the contractor and/or its subcontractors to applicable Singapore laws and regulations, including business registration, employment, labor, and tax requirements. The U.S. Government will not assist contractors in obtaining local approvals or resolving host country compliance matters. Offerors are encouraged to independently assess all local legal, regulatory, and tax obligations prior to submitting a quotation. All responsible sources may submit a quotation, which will be considered by the agency. | 61% | Pre-Solicitation | Open |
SOURCES SOUGHT SYNOPSIS The Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to support a requirement for Elevator Testing Services located at FHCC VAMC , North Chicago IL. o Captain James A. Lovell Federal Health Care Center, North Chicago, IL. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 341350. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Background: The purpose of this Contract is to provide for the inspection/testing of the vertical transportation system located at the Captain James A. Lovell Federal Health Care Center ( FHCC ), 3001 Green Bay Road, North Chicago, IL 60064-3048, as set forth in this Performance Work Statement. A complete listing of all vertical transportation system components, including thirty-one (31) elevators, two (2) cart lifts, and two (2) dumbwaiters (collectively VTS components ), is set forth in the Vertical Transportation System Schedule at the end of this Performance Work Statement. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Schedule at price(s) consistent with the current Price Schedule. A complete listing of all VTS Components, including twenty-nine (31) elevators, two (2) cart lifts, and two (2) dumbwaiters, is set forth in the Vertical Transportation System Schedule at the end of this Statement of Work. Any additional vertical transportation system components put into service after award of this Contract shall be included in the Vertical Transportation System Inventory at price(s) consistent with the current Price Schedule. If your organization has the potential capacity to perform these contract services, please provide the following information: 1) Organization name, address, email address, website address, if applicable, telephone number, and size and type of ownership for the organization; and 2) Tailored capability statements addressing the particulars of this effort and documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements. The Government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 10:00AM Local Time (Central) on November 11th, 2026. All responses under this Sources Sought Notice shall be emailed to Michelle.Klug2@va.gov. STATEMENT OF WORK Inspections Overview: The Contractor shall perform Annual Category 1, Semiannual, and Full-Load Category 5 VTS component inspection/testing as follows: a. Annual Category 1 inspection/testing is typically conducted in May of each year; a. Semiannual inspection/testing is typically conducted in November of each year; and b. Full-Load Category 5 testing will be performed in November 2027. c. Note: Typical inspection/testing dates are subject to change, in FHCC s sole discretion. Basic Contractor Responsibilities: The Contractor shall provide all personnel, equipment, material, parts, software, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary for execution of the work to be performed under this Contract. Any work found to be non-conforming to the terms of this Contract shall be promptly corrected by the Contractor at no additional cost to the Government. All work shall be performed in a neat and professional manner, including the removal of all trash and debris at the completion of all work. Contractor Limitations: The Contractor performing inspection/testing under this Contract is prohibited from performing any repairs or other work on any of the VTS components covered by this Contract. Safety: All work performed under this Contract shall conform to such safety precautions as the FHCC Fire/Safety and Engineering Departments determine, in their sole discretion, to be necessary, in addition to all other requirements set forth elsewhere in the Contract. Inspection/Testing Standards. 1. All inspection/testing of FHCC s vertical transportation system components shall comply with the most current version of the following standards: a. American Society of Mechanical Engineers ( ASME ) 17.1: Handbook on Safety Code for Elevators and Escalators; b. ASME 17.2: Guide for Inspection of Elevators, Escalators, and Moving Walks; c. ASME 17.3: Safety Code for Existing Elevators and Escalators; d. National Fire Protection Association ( NFPA ) 70: National Electrical Code; and e. NFPA 70E: Standard for Electrical Safety in the Workplace. 2. During any inspection/testing, parts shall be removed and equipment cleaned, as necessary, to determine their exact condition. All parts shall be properly reinstalled after removal. 3. All inspections shall be performed in the presence of an elevator maintenance technician, currently under contract as the VA elevator maintenance contractor, and the COR or designated FHCC representative. 4. Immediately following the conclusion of each inspection/testing, the Contractor shall brief the COR or designated FHCC representative regarding the inspection/testing results, including without limitation: code violations, safety concerns, and immediate maintenance needs. 5. The COR, in the COR s sole discretion, may reject any work performed under this Contract that is noncompliant with any of the requirements set forth in this Contract. All rejected work shall be corrected as quickly as reasonably possible at no additional expense to the Government. Inspection Checklists: The Contractor shall provide a fully completed inspection checklist applicable to each VTS component using the Checklist for Inspection of Electric Elevators The comments section of each checklist shall include a. If the VTS component is safe operating condition; a. If the VTS component will perform in accordance with Original Equipment Manufacturer ( OEM ) standards; b. Whether the VTS component has been altered, except in conformity with all applicable standards set forth in this Contract; c. If the VTS component has any deficiencies, referencing the appropriate standard as applicable; and d. Whether there are any recommended VTS component repairs or upgrades. e. Documentation. Upon completion of the inspection/testing of all FHCC s VTS components, the Contractor shall provide a report within thirty (30) days to the COR and other FHCC personnel as directed. The report shall be electronically submitted in pdf format utilizing word processing to the maximum extent practicable; individual file size shall not exceed 7 MB. Each report should include: Certificates of Inspection: The Certificate of Inspection for each VTS component shall include the following information: a. Location (building and city/state); a. Identification number; b. Capacity; c. Speed; d. Date of inspection; e. Name of inspector and company; f. Inspector s signature; and g. Inspector s Qualified Elevator Inspector ( QEI ) number. Scheduling Inspection/Testing: The Contractor shall coordinate a mutually agreeable time with the COR at least thirty (30) days prior to the typical inspection months, as defined above. Hours for Inspection/Testing: All work performed under this Contract shall be performed during normal hours of facility operation, as defined below, except for inspection/testing that, in the COR s judgment, may severely impact elevator service. Inspection/testing that severely impacts elevator service shall be conducted after normal hours of facility operation at no additional cost to the Government. Reinspection: If any VTS component(s) require reinspection, the Contractor shall: a. Provide a quote to the COR for the reinspection(s) at a price consistent with the Price Schedule s Unit Price for the current contract period; and a. Coordinate reinspection(s) with the COR only after a Contract Modification has been awarded authorizing such reinspection. b. Inspector Qualifications. Inspectors performing VTS component inspection/testing under this Contract shall be a currently certified Qualified Elevator Inspector by an ASME-accredited organization, in accordance with ASME QEI-1: Standard for the Qualification of Elevator Inspectors. Inspectors performing work under this Contract shall be regularly employed by the Contractor. The Contractor shall provide a copy of each inspector s QEI-1 certification to the COR prior to any VTS component inspection/testing being performed. c. Scheduling. d. On-Site Work Requirements. In addition to any other requirements set forth in this Contract, the Contractor shall comply with the following on-site work requirements: Contractor Orientation/Training: The Contractor shall attend an orientation prior to beginning any work under this Contract, at the COR s discretion. This orientation may include the following topics: Contract terms and conditions; performance monitoring; badging procedures; safety; fire procedures; severe weather procedures; disease transmission; infection control; disaster procedures; and any other topic deemed necessary by the COR. At the COR s discretion, the Contractor may be responsible for providing some or all this information/training to its employees, as directed by the COR. Check-in/Check-out Requirements: The Contractor shall comply with all facility check-in and screening requirements. Upon successful completion of the facility s check-in and screening process, the Contractor shall check-in with the COR, or the COR s designee, advising them of the nature and location of the work to be accomplished. The Contractor shall check-out with the COR, or the COR s designee, at the conclusion of such work, prior to departing the VA facility, advising them of the work completed and any problems/issues identified. Hours of Operation: Normal hours of facility operation ( Business Hours ) are Monday through Friday, 7:00 a.m. 3:30 p.m. Local Time, except for the following Federal Holidays: a. New Year s Day; a. Birthday of Martin Luther King, Jr.; b. Washington s Birthday; c. Memorial Day; d. Juneteenth National Independence Day; e. Independence Day; f. Labor Day; g. Columbus Day; h. Veterans Day; i. Thanksgiving Day; j. Christmas Day; **** Any other day declared a Federal Holiday by Presidential Proclamation**** Noninterference with Facility Functions: The Contractor shall perform its services under this Contract in a manner that does not interfere with the facility s functions, including maintaining all tools and equipment in an orderly fashion and cleaning the work area at the conclusion of a service visit. The Contractor shall interrupt its work at any time to not interfere with the normal functioning of the facility, including utility services, fire protection systems, and passage of facility patients, personnel, equipment, and carts. In the event of an emergency, Contractor MANUFACTURER TYPE ELEVATOR # LOCATION Inspection Frequency 1 SMARTRISE/HW TRACTION P-1 BLDG. 133 CA Annual May/Semi-Annual November 2 SMARTRISE/HW TRACTION P-2 BLDG. 133 CA Annual May/Semi-Annual November 3 SMARTRISE/HW TRACTION P-3 BLDG. 133 CA Annual May/Semi-Annual November 4 MID-AMERICAN TRACTION P-4 BLDG. 131 Annual May/Semi-Annual November 5 MID-AMERICAN TRACTION P-5 BLDG. 131 Annual May/Semi-Annual November 6 SMARTRISE/HW TRACTION P-7 BLDG. 133 Annual May/Semi-Annual November 7 SMARTRISE/HW TRACTION P-8 BLDG. 133 Annual May/Semi-Annual November 8 SMARTRISE TRACTION P-10 BLDG. 134 Annual May/Semi-Annual November 9 SMARTRISE TRACTION P-11 BLDG. 134 Annual May/Semi-Annual November 10 SMARTRISE TRACTION P-13 BLDG. 135 Annual May/Semi-Annual November 11 SMARTRISE TRACTION P-18 BLDG. 1 Annual May/Semi-Annual November 12 MID-AMERICAN HYDRAULIC P-20 BLDG. 46 Annual May/Semi-Annual November 13 MID-AMERICAN TRACTION P-21 BLDG. 66 Annual May/Semi-Annual November 14 MID-AMERICAN TRACTION P-22 BLDG. 7 Annual May/Semi-Annual November 15 MID-AMERICAN HYDRAULIC P-23 BLDG. 4 Annual May/Semi-Annual November 16 MID-AMERICAN HYDRAULIC P-24 BLDG. 133 Annual May/Semi-Annual November 17 SCHUMACKER ELEVATOR HYDRAULIC P-25 PARKING GARAGE 195 Annual May/Semi-Annual November 18 SCHUMACKER ELEVATOR HYDRAULIC P-26 PARKING GARAGE Annual May/Semi-Annual November 19 SCHUMACKER ELEVATOR HYDRAULIC P-1 BLDG. 133EF Annual May/Semi-Annual November 20 SCHUMACKER ELEVATOR HYDRAULIC P-2 BLDG. 133EF Annual May/Semi-Annual November 21 SMARTRISE HYDRAULIC S-1 BLDG. 133CA Annual May/Semi-Annual November 22 SCHUMACKER ELEVATOR HYDRAULIC S-1 BLDG. 133EF Annual May/Semi-Annual November 23 SCHINDLER HYDRAULIC S-2 BLDG. 6 Annual May/Semi-Annual November 24 SCHINDLER HYDRAULIC S-3 BLDG. 6 Annual May/Semi-Annual November 25 MID-AMERICAN TRACTION S-6 BLDG. 131 Annual May/Semi-Annual November 26 SMARTRISE TRACTION S-9 BLDG. 133 Annual May/Semi-Annual November 27 SMARTRISE TRACTION S-12 BLDG. 134 Annual May/Semi-Annual November 28 SMARTRISE TRACTION SF-14 BLDG. 135 Annual May/Semi-Annual November 29 KONE TRACTION P-27 PARKING GARAGE 196 Annual May/Semi-Annual November 30 TAC32H HYDRAULIC 556FH-ELEV-001-CO100 CORRIDOR 100 Annual May/Semi-Annual November 31 SMARTRISE HYDRAULIC 5-ELEV-E1-CO101 CORRIDOR 101 Annual May/Semi-Annual November FHCC VERTICAL TRANSPORTATION SYSTEM SCHEDULE ELEVATORS CART LIFTS MANUFACTURER CART LIFT # LOCATION INSPECTION FREQUENCY 1 LIFT-O-MATIC CART LIFT 1 BLDG. 133CA Annual May/Semi-Annual November 2 LIFT-O-MATIC CART LIFT 2 BLDG. 133CA Annual May/Semi-Annual November DUMBWATIERS DUMBWAITER # LOCATION INSPECTION FREQUENCY 1 DUMBWAITER 1 BLDG. 133 Annual May/Semi-Annual November 2 DUMBWAITER 2 BLDG. 133CA Annual May/Semi-Annual November | 61% | Market Research | 11/11/2026 |
Additional Details
Solicitation Number
W912PB25R3008
Archive Date
Jan 14, 2025
Place of Performance Country
DEU
Office Address