GovChime
Notice ID: 474e35f26f0e4581a0cde73f9e6592b5Sources SoughtArchived

Sources Sought/Market Intelligence: Fort Carson Equipment Concentration Site - Potential Use of Construction Management at Risk using Other Transaction Authority (OTA)

Archived on August 22, 2026. Original response deadline: . Full description on SAM.gov.

Overview

Response deadline
10:00 AM EDT
Posted
July 29, 2026
Notice type
Sources Sought
NAICS
236220: Commercial and Institutional Building Construction
Agency
Department of WarDepartment of the Army

Notice details

Office
W072 ENDIST LOUISVILLE
Place of performance
Colorado Springs, Colorado, 80913
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov

Identifiers

Solicitation number
W912QR-PDB-FortCarsonECS
Notice ID
474e35f26f0e4581a0cde73f9e6592b5

Description

REQUEST FOR INFORMATION (RFI) / MARKET INTELLIGENCE NOTICE Notice: This is a Request for Information (RFI) for market intelligence and for informational purposes only. This announcement does not constitute a Solicitation or a Request for Proposal (RFP), and no solicitation is currently available. Participation in this RFI is strictly voluntary. The Government will not be obligated to award any agreement or contract because of this RFI, nor will it reimburse respondents for any costs associated with the preparation or submission of information. Submitting a response will not affect a firm’s ability to submit a proposal should a formal solicitation be issued in the future. (Note: While Other Transaction Authority is not subject to FAR-based small business regulations, this NAICS code is provided for market research to help the Government understand the size and demographics of the interested industrial base. Small Business Size Standard: $45 Million) PROJECT OVERVIEW The U.S. Army Corps of Engineers (USACE), Louisville District, has a requirement for the design and construction of an Equipment Concentration Site (ECS) complex of facilities on Fort Carson. The scope of work consists of furnishing all necessary equipment, materials, labor, supervision, quality control, and supplies to deliver a fully functional Area Maintenance Support Activity (AMSA) shop, General Purpose Warehouse (GPW), and Organizational Storage Building. Key features of the project may include: Vehicle maintenance shop: required features including but not limited to concrete shop aprons, vehicle wash rack/platform, bi-level equipment loading ramps. Specialized Systems: special building foundations, extensive pavements, improved surfaces, and the related site clearing, and excavation costs associated with developing the 48-acre parcel of land. Administrative & Support: Adjoining maintenance shops, tool rooms, administrative offices, and personnel support spaces. Military Equipment Parking lot & Site Work: Construction of paving areas for heavy equipment, POVs, security fencing, and utility tie-ins. Estimated Acquisition Magnitude: $75,000,000.00 PLANNED ACQUISITION STRATEGY: CM@Risk via Other Transaction Authority (OTA) The Louisville District previously issued this RFI exploring a Progressive Design-Build (PDB) using Other Transaction Authority strategy. Based on recent project developments, the Government has advanced the design to approximately 35% and intends to progress to full design. The Government is now updating this market intelligence to assess industry capability and interest in utilizing Construction Management at Risk (CM@Risk) utilizing an Other Transaction (OT) Agreement under the authority of 10 U.S.C. § 2808a. This Course of Action utilizes the 10 U.S.C. § 2808a OT authority to execute a construction project where the design is at/near 95% completion. The builder is hired during Phase 1 to act as an expert consultant, helping the Designer of Record (DOR) push the design from 95% to 100% using real-time market data and MII (MCACES 2nd Generation) cost comparisons. Once the design hits 100% and the MII estimate validates the open-book pricing, the agreement transitions to Phase 2, where the builder goes "At-Risk" to construct the facility under a Guaranteed Maximum Price (GMP). The DOR retains design liability, but the contractor drives constructability and assumes responsibility for layout, schedule, and trade coordination. The Pricing Structure: Pre-Con Fee + Target Fee & GMP Preconstruction Services Fee: A small, fixed-price or time-and-materials amount paid to the contractor strictly to fund their time spent helping the A/E finalize the 95% design into a 100% design. The Target Fee: The contractor’s transparent profit margin for managing the actual construction, bid competitively upfront. The GMP: The absolute ceiling for the construction phase (Validated Direct Costs + Target Fee + Shared Contingency). PHASED EXECUTION PLAN Phase 1: Preconstruction Services Agreement (CM@Risk Advisory) Solicitation (White Papers): The Solicitation would likely include the 95% design. The Deliverable is anticipated to be a concise 5-to-10 page White Paper. Evaluation Criteria will likely include Corporate capability and CM@Risk past performance; preconstruction approach (how the firm plans to collaborate with the Government's A/E to close the remaining 5% design gap, identify value-engineering opportunities, and mitigate supply-chain risks); proposed Target Fee (for construction) and Preconstruction Services Fee. The Pitch Meeting (Oral Presentations): A 90-minute pitch where the contractor must bring their Project Manager, Site Superintendent, and their Preconstruction Manager. The Government team assesses how well the contractor's team will integrate with the A/E during the critical final design push. The OT is initially awarded and funded only for the Preconstruction Services Fee. Design Finalization (Bridging the 5% Gap): The contractor’s Preconstruction team sits with the Government and the DOR. Because the design is not locked, they can actively change it. They perform value engineering, finalize equipment selections, and ensure the drawings are 100% constructible. Open Book Pricing vs. MII: As the design reaches 100%, the contractor conducts open-book market outreach. The Government and contractor review actual sub-bids together. USACE cost estimators finalize the Independent Government Estimate (IGE) using the MII software to validate costs and establish the GMP base. Phase 2: Construction Execution Agreement (Going "At-Risk") Execution: The Agreements Officer (AO) executes a bilateral modification to the OT Agreement, incorporating the GMP and funding the physical construction. Risk Allocation: Under CM@Risk, the contractor is now "At-Risk." While the DOR still owns fundamental engineering failures, the contractor loses the ability to claim "defective design" for constructability issues, material delays, or coordination errors, because they were explicitly paid to help finalize those exact decisions using market and MII data during Phase 1. INFORMATION REQUESTED 1. Company Profile: Firm Name, Address, and Point of Contact (Name, Title). Phone Number, Email Address, and Unique Entity ID (UEI). Socioeconomic Status (Large, Small, 8(a), SDVOSB, etc.). 2. Other Transaction Authority (OTA) & Statutory Compliance: Innovative Technologies: Describe any innovative materials, methods, or technologies your firm could propose for a project of this scale that could lead to cost savings, schedule acceleration, or enhanced facility performance and resilience. Barriers to Innovation: What commercial or Government-imposed barriers currently make it difficult to propose or implement innovative construction technologies? How could the flexibility of an OTA help overcome these barriers? 3. CM@Risk & Design-Assist Involvement: 95% Design Entry: The Government plans to bring the CM@Risk contractor on board when the design is at 95%. Based on your experience, is a 5% design gap sufficient to add meaningful constructability and value-engineering input, or are the most critical decisions already locked in?[MH1] Collaborative Framework: What collaborative mechanisms do you recommend the Government implement to rapidly close the 5% design gap and transition to a validated GMP? Describe your experience executing Construction Manager at Risk (CMAR) or other highly collaborative delivery methods, particularly where you served as an advisor before going "at-risk". 4. Guaranteed Maximum Price (GMP), Risk Allocation & Compensation: Preconstruction Compensation: What specific compensation structures (e.g., fixed stipends, time-and-materials) would best compensate your firm for the pre-construction effort and design-assist phase? Open Book Pricing: How do you approach "open-book" pricing and transparency during Phase 1 to build trust and ensure the Government is receiving fair market value before locking in the GMP? Long-Lead Items: How do you handle the procurement of long-lead items (e.g., switchgear, specialized fire pumps, large span steel) if they must be ordered prior to the finalization of the 100% design and GMP? Phase 1 Off-Ramp Risk: If the Government and the contractor cannot reach an agreement on the final GMP, what specific off-ramp conditions are critical to your firm? 5. Industrial Maintenance & Storage Facility Construction Expertise: Describe your specific experience with large-scale heavy tactical maintenance facilities, specialized systems like tactical vehicle wash platforms, and highly specialized fire suppression systems. What are the greatest supply chain, scheduling, or technical risks you foresee for a project of this type at Fort Carson, and how would this CM@Risk delivery method help mitigate them? 6. Teaming & Subcontractor Integration: Under a CM@Risk model starting at a 95% design, how and when do you plan to on-board your critical subcontractors (e.g., structural steel, MEP, fire protection)? Will you compete these subcontracts openly during Phase 1 to build the open-book GMP, or do you prefer bringing in established partners from day one? 7. Feedback on the Acquisition Strategy & Alternatives: Does the proposed CM@Risk-OTA strategy incentivize your firm to participate? Why or why not? Are there alternative acquisition strategies, phasing approaches, or commercial practices the Government has not considered that would yield a better facility, faster delivery, or lower cost? 8. Bonding Capability: Specify your maximum bonding (Single and Aggregate) as a Sole Prime Contractor and/or as a Joint Venture. SUBMISSION INSTRUCTIONS Please email your responses in PDF format to Chris Brackett at Christopher.Brackett@usace.army.mil by 07 August 2026 at 1000 Eastern Time. [MH1]This is my biggest sticking point. I’ll be curious as to Industry feedback on this and if they feel taking the at risk for only providing input at the final 5% design stage is going to be enough to go in on an agreement.

Full description on SAM.gov

Award Overview

No prior contract identified

No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.

Contacts

Contracting Officer

Documents

No documents available.

Lifecycle

  1. 1
    Version 1Sources SoughtArchived

    Fort Carson Equipment Concentration Site: Potential Use of Progressive Design Build using Other Transaction Authority (OTA)

    Notice 739c2a278c6148a49dd168c645c51881 on SAM.gov

  2. 2
    Version 2Sources SoughtArchived

    Fort Carson Equipment Concentration Site: Potential Use of Progressive Design Build using Other Transaction Authority (OTA)

    Notice 1aa4a6101d2e447aa7e287e888112051 on SAM.gov

  3. 4
    Version 4Sources SoughtArchived

    Sources Sought/Market Intelligence: Fort Carson Equipment Concentration Site - Potential Use of Progressive Design Build using Other Transaction Authority (OTA)

    Notice f46a14d7122b431a9b7ec553eea006d9 on SAM.gov

  4. 5
    Version 5Sources SoughtArchived

    Sources Sought/Market Intelligence: Fort Carson Equipment Concentration Site - Potential Use of Progressive Design Build using Other Transaction Authority (OTA)

    Notice 4486a70e667e4326bd32b18ce897a1b3 on SAM.gov

  5. 7
    Version 7Sources SoughtArchivedCurrent

    Sources Sought/Market Intelligence: Fort Carson Equipment Concentration Site - Potential Use of Construction Management at Risk using Other Transaction Authority (OTA)

    Notice 474e35f26f0e4581a0cde73f9e6592b5 on SAM.gov

  6. 8
    Version 8Special Notice

    Type changed from Sources Sought to Special Notice

    INDUSTRY DAY: Fort Carson Equipment Concentration Site - Construction Management at Risk using Other Transaction Authority (CM@Risk w/OTA)

    Notice 2f9b07d669b44f4aa080617dbc7b95a9 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
*** 13 October 2026 UPDATE ***: Formal Request for Qualifications has been issued under Notice ID: W912QR279A001. The RFQ was issued 13 October. Responses are currently due 28 October. See RFQ posting for additional details. The U.S. Army Corps of Engineers (USACE) is issuing this special notice to announce an upcoming competition for construction solicitation for Fort Carson ECS using CM@Risk under 10 USC §2808a Other Transaction Authority for Construction. This notice is for informational and planning purposes to allow interested parties to prepare for and provide feedback prior to the official solicitation release. I. INDUSTRY DAY USACE intends to conduct an Industry Day on 06 October 2026 at 0900 Mountain Time to provide an overview of the project, acquisition strategy, and anticipated requirements. This event will provide interested parties with an opportunity to gain additional insight into the project and proposed Construction Manager at Risk (CM@Risk) approach under an Other Transaction (OT) framework, ask questions, and provide input in advance of the official Request for Qualifications (RFQ) release. General questions from industry participants will be permitted during the Industry Day; however, all discussions and responses provided during the event are considered unofficial and are for informational purposes only. Statements made during the Industry Day do not constitute a commitment, authorization, or binding guidance related to the future Request for Qualifications (RFQ). Official Questions and Answers (Q&A) will be accepted and addressed following the release of RFQ. Please use the direct special event link below to register for access to Fort Carson. You must be a U.S. Citizen and have a REAL ID to complete registration. If you do not, you must go the Fort Carson Visitor Control Center (located at Gate 1, located off 115 HW) with your State ID plus a U.S. Passport OR Certified birth certificate and Social Security Card to obtain access. Individuals with a valid CAC, should be able to access the installation directly. Direct Special Event Link https://pass.aie.army.mil/?b=usa&i=carson&e=M6JLHPVK Physical Access Control POC: Mark Elliott (719) 466-1132 mark.d.elliott24.civ@army.mil II. LOCATION/LOGISTICS Industry Day Presentation location: Butts Army Airfield Hangar – 9620 Son Tay Road NOTE: Onsite parking space may be limited, overflow parking is available in the vicinity Site Visit – Primary parking lot is at the CBRN Chamber across the tank trail at the intersection of Minick Ave and Prussman Blvd. Additional parking is available on Minick Ave less than a quarter mile NW of the CBRN Chamber lot. Onsite Directions Link Below. Turn by turn directions and map attached for download. https://maps.app.goo.gl/U4o1XusLDWip4gn87 III. PROJECT OVERVIEW Project Title: Construction of an Equipment Concentration Site (ECS) Complex Location: Fort Carson, Colorado Agency: U.S. Army Corps of Engineers, Louisville District NAICS Code: 236220 IV. PROJECT DESCRIPTION This acquisition will deliver a consolidated, fully functional ECS complex on an undeveloped 48-acre parcel of land at Fort Carson, CO. This site features a comprehensive range of facilities designed to support the mission of ECS-42, which is responsible for the maintenance and storage of key military assets assigned to 83 regional Army Reserve units. The operational readiness of this military equipment is essential for both training Army Reserve Soldiers and equipping units from which the Active component will draw upon for critical warfighting capabilities inherent to deployable combat forces. Core Facilities include: General Purpose Warehouse (GPW): A 39,313 square-foot (SF) secure, clear-span storage facility designed for the protection and preservation of military equipment. Area Maintenance Support Activity (AMSA) Shop: A 26,217 SF vehicle maintenance facility featuring advanced vehicle maintenance exhaust systems, overhead cranes, heavy-duty hoists, and specialized tool rooms. Organizational Storage Building: A 5,000 SF high-bay vertical storage facility. Container Storage Area: A 4,440-square-yard (SY) reinforced concrete layout for secure tactical container storage. Supporting Infrastructure & Specialized Systems include: Heavy Equipment Parking & Site Work: A Military Equipment Parking (MEP) lot featuring extensive heavy-duty concrete pavements designed to withstand high-shear tracked and wheeled tactical vehicle loads, alongside POV parking, security fencing, and utility tie-ins. Tactical Vehicle Wash Facilities: Two dedicated, high-capacity vehicle wash racks/platforms featuring industrial filtration and water-recycling systems. Bi-Level Loading Ramp: A reinforced bi-level loading ramp designed to facilitate the rapid loading and unloading of heavy armored vehicles onto transport carriers. Specialized Foundations: Geotechnical engineering solutions, including deep foundation systems and soil stabilization, to mitigate volatile soil conditions across the 48-acre site. Fire Protection: Advanced fire detection and suppression systems, including specialized solutions for high-bay maintenance areas and hazardous material storage, compliant with all relevant UFC and NFPA standards. Cybersecurity: Facility-related control systems will be designed and implemented in accordance with UFC 4-010-06, ensuring the cybersecurity of all networked building systems. UFC Compliance: The entire facility complex will be designed and constructed to meet all applicable Unified Facilities Criteria (UFC), including AT/FP (Antiterrorism/Force Protection) standards and sustainable design principles as outlined in the Army Sustainable Design and Development Policy. V. ACQUISITION STRATEGY - PRE-AWARD USACE, Louisville District will use a streamlined competitive selection process: Step 1 –White Papers: Interested parties will submit a Statement of Qualifications (max # of pages to be defined in formal RFQ). Following evaluation of the qualification packages, the Government intends to down-select up to three (3) highest qualified firms to proceed to Step 2. Step 2 – Pitch Presentations: Down-selected firms will participate in live pitch meetings. One company will be selected as the Construction Manager for negotiation and award of Agreement 1 for preconstruction services. The Government intends to negotiate a Guaranteed Maximum Price (GMP) for construction of the ECS, which will be added as a bilateral modification at a later date. VI. ACQUSITION STRATEGY – AWARD The agreement will be awarded to the most qualified Construction Manager at Risk (CMAR) to provide preconstruction services and construction. Phase 1 of the CM@Risk agreement will include pre-construction services. The selected CMAR will act as an expert consultant to the Government, collaborating directly with USACE and the third-party Designer of Record during active design progression. The Government’s intent is to award the Phase I Agreement for Preconstruction Services prior to the 65% design review meeting. Phase 2 of the agreement will include scope for all construction activities necessary to complete the project. The agreement will be Firm-Fixed-Price (FFP). All interested parties should monitor the official solicitation announcement, which will provide complete details and submission instructions. Draft documents may be provided at a future date for feedback and informational purposes only and are subject to change upon issuance of the formal Project RFQ. VII. Virtual Participation Opportunity: For those who are unable to attend the Industry Day even in person, the Louisville District plans to stream the event through Microsoft Teams. The details related to the MS Teams event are provided below: Microsoft Teams meeting Join: https://dod.teams.microsoft.us/meet/993580238205?p=NgWECEurH73BprxGc1 Meeting ID: 993 580 238 205 Passcode: kB2Fr9e2
-Special Notice10/06/2026
This project is open to contractholders on the National IDIQ for Consatruction in Zone D only. They are: Akima Intra-Data, LLC Thomson, James dba American Southwest Electric Anderson Burton Construction Inc B.C. Schmidt Construction, Inc .Bilbro Construction Company, IncD7, LLC dba Dawson D7DCR Services & Construction, Inc .Defender Contracting & Construction LLC Glen/Mar Construction, Inc GMH-C JV, LLCGoshawk, LLC Ironwood Commercial Builders Inc Leisnoi Professional Services LLC Middle Canyon Electric, LLC North Star Construction and Engineering, Inc. dba North Star Construction Pilkington Contracting Co., Inc. dba Pilkington Construction Co. Sea Pac Engineering, Inc SEI Group, Inc Silver Mountain Weston SB JV, LLC Southeastern Industrial Barlovento JV Su-Mo Builders, Inc Tazlina River Contractors If you are a subcontractor, please contact any of the primaries listed above. See the attached soclicitation package for details on the project. Please give 24 to 48 hours for requests as this is not an automated feature.
-Combined Synopsis11/17/2026
-Solicitation12/07/2026
-AwardedOpen
MT RAINIER - MORA- NEW CAMP MUIR GUIDE BLDGS
-Solicitation12/10/2026

Additional Details

Solicitation Number

W912QR-PDB-FortCarsonECS

Archive Date

Aug 22, 2026

Office Address

LOUISVILLE, KY, 40202-2230