Notice ID: 8fcd71e8828345feb39348e886a5b6b2Solicitation
Replace and Construct Type III Hydrant Fuel System at WPAFB
Archived on May 1, 2021. Original response deadline: . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM UTC−04:00
- Posted
- April 14, 2021
- Notice type
- Solicitation
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- W072 ENDIST LOUISVILLE
- Place of performance
- Wright Patterson AFB, 45433
- Last updated
- Sep 25, 2026
Identifiers
- Solicitation number
- W912QR21R0006
- Notice ID
- 8fcd71e8828345feb39348e886a5b6b2
Description
AMENDMENT 0001: See attachment for changes to price breakout schedule, evaluation criteria, plan sheets or specs and wage rate updates. AMENDMENT 0002: See attachment for changes to price breakout schedule, evaluation criteria, plan sheets or specs, and wage rate updates. AMENDMENT 0003: See attachment for changes to the wage rate updates. AMENDMENT 0004: See attachment for changes to the Price Breakout Schedule, additional spec, and change in due date. AMENDMENT 0005: See attachment for changes to the wage rate updates. DESCRIPTION: The U.S. Army Corps of Engineers (USACE) Louisville District Request for Proposal (RFP) W912QR21R0006 for the Replace and Construct Type III Hydrant Fuel System, Wright Patterson Air Force Base, Ohio. The proposed project will construct a new Type III Hydrant System with two 5,000-barrel aboveground storage tanks and a 2,400 GPM pump house, and issue/return piping 12-inch hydrant loop. The existing hydrant loop with 14 in-apron hydrant pits shall remain in service. Project demolition will include removal of four 50,000-gallon underground storage tanks and the Type II pumphouse. The project will also construct a single-position emergency/secondary truck offload stand, hydrant hose truck checkout stand, and product recovery tank. Associated features include access roads, concrete secondary containment, containment drainage, provisions for temporary pig launcher and receiver, control systems, security fencing, and lighting TYPE OF CONTRACT AND NAICS: This RFP will be for one (1) Firm-Fixed-Price (FFP) contract. The North American Industrial Classification System Code (NAICS) for this effort is 237120 (Oil and Gas Pipeline and Related Structures Construction). TYPE OF SET-ASIDE: This is a Full and Open procurement. In accordance with Federal Acquisition Regulation 19.1307, this project requires the HUBZone 10% price evaluation. CONSTRUCTION MAGNITUDE: The magnitude of this construction project is anticipated to be between $10,000,000 and $25,000,000, in accordance with DFARS 236.204. SELECTION PROCESS: This is a single-phase procurement. The proposals will be evaluated using a Best Value Tradeoff source selection process. The technical information contained in each offeror's proposal will be reviewed, evaluated, and rated by the Government. Proposals for this procurement, at a minimum, will consist of the following: Prime Contractor Past Performance; Technical, and Price. Pro Forma Information such as bonding and financial capability will also be required to meet the minimum requirements of the solicitation. All evaluation factors, other than cost or price, are considered approximately equal to cost or price. DISCUSSIONS: The Government intends to award without discussions but reserves the right to conduct discussion should it be deemed in the Government's best interest. SOLICITATION WEBSITE: The official solicitation, when posted, will be available free of charge by electronic posting only and may be found at beta.SAM Contract Opportunities website, http://www.beta.SAM.gov. Paper copies of the solicitation will not be issued. Telephone and Fax requests for this solicitation will not be honored. Project files are Portable Document Format (PDF) files and can be viewed, navigated, or printed using Adobe Acrobat Reader. To download the solicitation for this project, contractors are required to register at the beta.SAM website at http://www.beta.SAM.gov. Amendments, if/when issued, will be posted to the above referenced website for electronic downloading. This will be the only method of distributing amendments prior to closing; therefore, it is the Offerors responsibility to check the website periodically for any amendments to the solicitation. REGISTRATIONS: Offerors shall have and shall maintain an active registration in the following database: System for Award Management (SAM): Offerors shall have and shall maintain an active registration in the SAM database at http://www.sam.gov to be eligible for a Government contract award. If the Offeror is a Joint Venture (JV), the JV entity shall have valid SAM registration in the SAM database representing the JV as one business/firm/entity. If at the time of award an Offeror is not actively and successfully registered in the SAM database, the Government reserves the right to award to the next prospective Offeror. POINT-OF-CONTACT: The point-of-contact for this procurement is Contract Specialist, Miriaha Sigmon, at Miriaha.D.Sigmon@usace.army.mil.
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Secondary Contact
Documents
No documents available.
Lifecycle
Solicitation:
W912QR21R0006- Pre-Solicitation
- Solicitation
Award typically follows within 30–90 days after the response deadline. (estimate)
- Pre-SolicitationOct 29, 2020
Replace and Construct Type III Hydrant Fuel System at WPAFB
- 8×SolicitationCurrentNov 20, 2020
Replace and Construct Type III Hydrant Fuel System at WPAFB
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
Additional Details
Solicitation Number
W912QR21R0006
Archive Date
May 1, 2021
Office Address
LOUISVILLE, KY, 40202-2230