GovChime
Notice ID: 4c5486506595b07498eee945f933a3f9Award NoticeAwarded

RECOVERY--Z--FOX POINT HURRICANE BARRIER - Upgrades to the ElectroMechanical Control System, Providence, RI

Awarded on September 29, 2010. Full description on SAM.gov.

Awarded tounder W912WJ-10-C-0032 (source: SAM.gov award notice)• $908.3K

Overview

Posted
October 1, 2010
Notice type
Award Notice
Agency
Department of WarDepartment of the Army

Notice details

Office
W2SD ENDIST NEW ENGLAND
Place of performance
USACE District, New England 696 Virginia Road, Concord MA 01742-2751 US
PSC
Z: MAINT, REPAIR, ALTER REAL PROPERTY
Last updated
Dec 5, 2025
Award date
Sep 29, 2010
Award amount (SAM.gov award notice)
$908.3K

Identifiers

Solicitation number
W912WJ10B0014
Notice ID
4c5486506595b07498eee945f933a3f9
Award number (PIID)
W912WJ-10-C-0032

Description

Fox Point Hurricane Barrier is a 700-foot long concrete barrier and includes a pump station with five 4,500hp pumps and three 40-foot by 40-foot tainter gates. The project also includes 2,200 feet of dikes. Fox Point provides protection to tens of thousands of residents and $5 billion worth of property. Lately, the operation of the pumps at the Fox Point Hurricane Barrier has become unreliable due to an antiquated control system. The purpose of this work is to improve station service reliability and provide a modern, up-to-date electromechanical control system. The following electrical upgrade work must be accomplished. The construction contract work includes: - Replacement of 8 existing 4160V switchgear and relays with vacuum breaker switchgear and digital multifunction protection relays. Remote breaker racking to be included; - Relocation/replacement of existing pump and gate controllers and replacement of annunciator relay system with a digital Programmable Logic Controller (PLC); - Replacement and relocation of existing pump station battery system used to trip the 4160V breakers; - Replacement of 5KV power cables from each of five 4500 hp electric pumps to the switchgear; - Diagnosis/repairs to the nitrogen cooling system on 11KV electric transformers; - ARC Flash Hazard analysis, testing, certification.

Full description on SAM.gov

Award Overview

Award Number

W912WJ-10-C-0032

Award Amount (SAM.gov award notice)

$908.3K

Award Date

Sep 29, 2010

Awardee

Original Solicitation

Notice ID: 4c5486506595b07498eee945f933a3f9

Posted Date: Oct 1, 2010

Original Response Deadline: Not specified

Contacts

Contracting Officer

Primary Contact

Brad Schweitzer, 978-318-8022 USACE District, New England

Documents

No documents available.

Lifecycle

Solicitation:W912WJ10B0014
  1. Pre-Solicitation
  2. Solicitation
  3. Awarded

This opportunity has been awarded.

  1. 5×
    Pre-SolicitationJun 17, 2010

    RECOVERY--Z--PROJECT NUMBER 006100, FOX POINT HURRICANE BARRIER - Upgrades to the ElectroMechanical Control System, Providence, RI

    Notice 4f610f8752ecfa464775f78f84ccca00 on SAM.gov

  2. SolicitationSep 10, 2010

    RECOVERY--Z--PROJECT NUMBER 006100, FOX POINT HURRICANE BARRIER - Upgrades to the ElectroMechanical Control System, Providence, RI

    Notice 05fb16e5f6a4dbc7d45154b8c8dcd587 on SAM.gov

  3. AwardedCurrentOct 1, 2010

    RECOVERY--Z--FOX POINT HURRICANE BARRIER - Upgrades to the ElectroMechanical Control System, Providence, RI

    Notice 4c5486506595b07498eee945f933a3f9 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline

Additional Details

Solicitation Number

W912WJ10B0014

Archive Date

Nov 8, 2010