Notice ID: 8e84a1ae0fda4879bc3f970869e99fffCombined Synopsis/Solicitation
Commercial Diesel Generator Set, 600kW Standby 60Hz
Responses closed . Full description on SAM.gov.
Overview
- Response deadline
- 2:00 PM EDT
- Posted
- May 7, 2026
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS
- 335312: Motor and Generator Manufacturing
- Agency
- Department of WarDepartment of the Army
Notice details
- Office
- AMC.ACC.MISSION INSTALLATION CONTRACTING COMMAND.419TH CSB.W6QM MICC-FT DRUM
- Place of performance
- 4525 Camp Hale Rd Fort Drum, NY 13602, 13602
- Last updated
- Oct 28, 2026
- First published
- Last updated on SAM.gov
Identifiers
- Solicitation number
- W911S226U3180
- Notice ID
- 8e84a1ae0fda4879bc3f970869e99fff
Description
Amended to include set aside code. Characteristics:600DQCA, Diesel Genset, 60Hz, 600kW, Duty Rating - Standby Power (ESP), Emission Certification, EPA, Tier 2, NSPS CI Stationary Emergency, Listing- UL 2200, Voltage - 277/480, 3 Phase, Wye, 4 Wire, Alternator - 60Hz, Wye, 480 Volts,105C ? Standby, Alternator Heater, 120 Volt AC, Steel Sound Attenuated Level 2Enclosure, with Exhaust System, Enclosure Color - Green, Steel, Cooling Air Outlet -Horizontal, Sound Attenuated, Louvers - Air Inlet, 24 Volts DC Spring Closed, Motor Opened, Louvers - Air Outlet, 24 Volts DC Spring Closed, Motor Opened, Distribution Panel - Prewired AC Features, Fuel Tank - Sub Base, 2400 Gallon, UL142 Compliant, Listing, ULC - S601 ? 07, Alarm - High Fuel Fill, Fuel Tank Connection - Dual Stub Up,Fuel Water Separator, Control Mounting - Left Facing, Power Command 2.3 Controller, LCD Control Display, Stop Switch - Emergency, Externally Mounted, Signals - Auxiliary,8 Inputs/8 Outputs, Control Display Language ? English, Circuit Breaker or Entrance Boxor Terminal Box - Right Only, Terminal Box- Low Voltage, Left- None, Circuit Breaker -1200A, Right, 3P, UL 600, IEC 415, UL Serv Ent, 100%, Circuit Breaker or Entrance Boxor Terminal Box, Top Entry, Left- None, Bottom Entry, Right, Engine Air Cleaner - Normal Duty, External Battery Charger - 12 Amp, Regulated, Engine Cooling - Radiator, 50CAmbient, Shutdown - Low Coolant Level, Coolant Heater - 208/240/480 Volts AC, Below40F Ambient Temperature, Genset Warranty - 2 Years Base, Literature ? English, Packing -None, Base Mounted Housing, OTECD, OTEC Transfer Switch- Electronic Control:
Award Overview
No prior contract identified
No prior award matched this notice's agency, NAICS, place of performance and PSC within 18 months. It may be a new requirement.
Contacts
Contracting Officer
Primary Contact
Documents
Links (4)
- PIEE Solicitation Module Link for W911S226U3180piee.eb.milPosted
- Web Based Training for the PIEE Solicitation Modulepieetraining.eb.milPosted
- Registration Instructions for the PIEE Solicitation Modulewww.acq.osd.milPosted
- Department of Defense Procurement Toolboxdodprocurementtoolbox.comPosted
Lifecycle
- 1Version 1Combined Synopsis/Solicitation
Commercial Diesel Generator Set, 600kW Standby 60Hz
- 2Version 2Combined Synopsis/SolicitationCurrent
Commercial Diesel Generator Set, 600kW Standby 60Hz
Similar Opportunities
Title | Match | Phase | Deadline |
|---|---|---|---|
150 kW Generator Dual FuelStandby Generator120/2083 Phase Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001 - Due date change. Amendment 0002 - EPA requirement correction. | 100% | Combined Synopsis | 09/18/2026 |
350 kW Generator Dual Fuel Standby Generator 120/208 3 Phase. Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001- Due Date Modification. Amendment 0002- Corrected inaccurate EPA requirements. | 100% | Combined Synopsis | 09/18/2026 |
150 kW Generator Dual Fuel Standby Generator120/2083 Phase Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001 - Correction to EPA requirements. | 100% | Combined Synopsis | 09/18/2026 |
180 kW Generator Dual FuelStandby Generator120/2083 Phase Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001 - corrections to EPA requirements. | 100% | Combined Synopsis | 09/18/2026 |
150 kW Generator Dual Fuel Standby Generator277/4803 Phase Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Amendment 0001 - Corrections to EPA requirements | 100% | Combined Synopsis | 09/18/2026 |
Additional Details
Solicitation Number
W911S226U3180
Archive Date
May 7, 2027
Office Address
FORT DRUM, NY, 13602-5220