GovChime
Notice ID: 5840fe9556024fad810c6b83a4959d74Award NoticeAwardedArchived

Z--BLM-CO RGFO PARK CENTER WELL VALVE REPLACEMENT

Awarded on September 25, 2026. Full description on SAM.gov.

Awarded tounder 140L1726C0001 (source: SAM.gov award notice)• $790.0K

Overview

Posted
September 25, 2026
Notice type
Award Notice
NAICS
213112: Support Activities for Oil and Gas Operations
Agency
Department of the InteriorBUREAU OF LAND MANAGEMENT

Notice details

Office
COLORADO STATE OFFICE
Place of performance
Latitude 38.521286, Longitude -105.214619, Canon City, CO, 81212
Last updated
Oct 28, 2026
First published
Last updated on SAM.gov
Award date
Sep 25, 2026
Award amount (SAM.gov award notice)
$790.0K

Identifiers

Solicitation number
140L1726Q0022
Notice ID
5840fe9556024fad810c6b83a4959d74
Award number (PIID)
140L1726C0001

Description

BLM-CO RGFO PARK CENTER WELL VALVE REPLACEMENT

Full description on SAM.gov

Award Overview

Award Number

140L1726C0001

Award Amount (SAM.gov award notice)

$790.0K

Award Date

Sep 25, 2026

Awardee

Awardee UEI

V7FAN2J2XPR7

Awardee CAGE Code

23LR4

Awardee Address

3040 E MAIN ST, Canon City, CO 81212, UNITED STATES

Original Solicitation

Notice ID: 5840fe9556024fad810c6b83a4959d74

Posted Date: Sep 25, 2026

Original Response Deadline: Not specified

More From This Vendor

Top 5 most recent

1
  • 140L1726C0001
    FLORENCE OILWELL SERVICES LLC
    Department of the InteriorNAICS 213112
    $790.0KSigned Sep 25, 2026

Contacts

Contracting Officer

Primary Contact

Voigt, Scott
Fax: 3032393699

Documents

Files (21)

  • Sol_140L1726Q0022_Amd_0006.pdf

    203 KBAdded in Solicitation version 8Posted
    Download
  • B11_COMPREHENSIVE_QA_PARK_CENTER_WELL_0006.pdf

    167 KBAdded in Solicitation version 8Posted
    Download
  • Sol_140L1726Q0022_Amd_0005.pdf

    211 KBAdded in Solicitation version 6Posted
    Download
  • B08_140L1726Q0022_UPDATED_SECTION_M_0005.pdf

    60 KBAdded in Solicitation version 6Posted
    Download
  • B08_140L1726Q0022_UPDATED_SECTION_C_0005.pdf

    48 KBAdded in Solicitation version 6Posted
    Download
  • B08_140L1726Q0022_UPDATED_SECTION_L_0005.pdf

    76 KBAdded in Solicitation version 6Posted
    Download
  • B08_140L1726Q0022_UPDATED_SECTION_B_0005.pdf

    67 KBAdded in Solicitation version 6Posted
    Download
  • B08_SCHEDULE_OF_ITEMS_PARK_CENTER_WELL_v07_30_2026_0005.pdf

    288 KBAdded in Solicitation version 6Posted
    Download
  • A05_SOO_PARK_CENTER_WELL_MAIN_VALVE_REPLACEMENT_v07_31_26_0005.pdf

    2.8 MBAdded in Solicitation version 6Posted
    Download
  • Sol_140L1726Q0022_Amd_0004.pdf

    202 KBAdded in Solicitation version 5Posted
    Download
  • Sol_140L1726Q0022_Amd_0003.pdf

    206 KBAdded in Solicitation version 4Posted
    Download
  • Sol_140L1726Q0022_Amd_0002.pdf

    206 KBAdded in Solicitation version 3Posted
    Download
  • A06_Park_Center_Well_Specs_pgs__34_-_88_0002.pdf

    624 KBAdded in Solicitation version 3Posted
    Download
  • A06_Park_Center_Well_Drawings_89_-_100_0002.pdf

    2.6 MBAdded in Solicitation version 3Posted
    Download
  • B08_Park_Center_Well_Main_Valve_Replacement_-_Schedule_of_Items_V6_24_26_0002.pdf

    119 KBAdded in Solicitation version 3Posted
    Download
  • Sol_140L1726Q0022_Amd_0001.pdf

    201 KBAdded in Solicitation version 2Posted
    Download
  • A05_SOO_PARK_CENTER_WELL_MAIN_VALVE_REPLACEMENT_v6_22_26_0001.pdf

    2.1 MBAdded in Solicitation version 2Posted
    Download
  • B08_Park_Center_Well_Main_Valve_Replacement_-_Schedule_of_Items_0001.pdf

    108 KBAdded in Solicitation version 2Posted
    Download
  • Sol_140L1726Q0022.pdf

    404 KBAdded in Solicitation version 1Posted
    Download
  • B03_CO20260003.pdf

    1.9 MBAdded in Solicitation version 1Posted
    Download
  • A05_SOO_PARK_CENTER_WELL_MAIN_VALVE_REPLACEMENT.pdf

    2.1 MBAdded in Solicitation version 1Posted
    Download

Lifecycle

  1. 2
    Version 2SolicitationArchived

    Z--PARK CENTER WELL VALVE REPLACEMENT

    Notice 0a8c69eafab44781b323c8aa08b75531 on SAM.gov

  2. 5
    Version 5Award NoticeArchivedCurrent

    Type changed from Solicitation to Award Notice

    Z--BLM-CO RGFO PARK CENTER WELL VALVE REPLACEMENT

    Notice 5840fe9556024fad810c6b83a4959d74 on SAM.gov

Other notices for this solicitation

  1. SolicitationRelated noticeJun 22, 2026

    Z--PARK CENTER WELL VALVE REPLACEMENT

    Notice 3fc3e491f3514d718a7c667c47590288 on SAM.gov

  2. SolicitationRelated noticeJun 22, 2026

    PARK CENTER WELL VALVE REPLACEMENT

    Notice d3d3d3008a4144ca9272ebadd1259148 on SAM.gov

  3. SolicitationRelated noticeJun 24, 2026

    Z--PARK CENTER WELL VALVE REPLACEMENT

    Notice d57edceda3ce4f40bf7aa3b7c66507eb on SAM.gov

  4. SolicitationRelated noticeJul 6, 2026

    Z--PARK CENTER WELL VALVE REPLACEMENT

    Notice b043de7a941b4f13b91debe42526a327 on SAM.gov

  5. SolicitationRelated noticeJul 13, 2026

    Z--PARK CENTER WELL VALVE REPLACEMENT

    Notice c21b31da57bb453382b88b4c305e8751 on SAM.gov

  6. SolicitationRelated noticeAug 4, 2026

    Z--PARK CENTER WELL VALVE REPLACEMENT

    Notice 4e9047c1366e4c1685da777c3539e163 on SAM.gov

Similar Opportunities

Title
Match
Phase
Deadline
YOSE 22866 Rehabilitate Hodgdon Meadows Water System and YOSE 196755 Extend Hodgdon Meadow Campground Sewer
-Market Research11/02/2026
-Solicitation11/06/2026
DEPARTMENT OF VETERANS AFFAIRS NETWORK CONTRACTING OFFICE 21 (NCO 21) Description: THIS IS A PRE-SOLICITATION NOTICE FOR A REQUEST FOR QUOTE (RFQ). VA Southern Nevada Health Care System (VASNHCS) has a future need for fuel tank cleaning, inspection, sampling, testing of fuels quality, restoration and fueling of 9 underground diesel fuel tanks for the VA Palo Alto Health Care System (VASNHCS) located at 6900 North Pecos Road, North Las Vegas, NV 89086-4400. Solicitation Number 36C26127Q0089 for this effort will be posted to SAM.GOV (https://sam.gov) on or about October 23, 2026. This solicitation will contain all necessary specifications and information necessary to quote the project. See solicitation for when questions must be submitted. Quotes are tentatively scheduled to be due on November 6, 2026 (see solicitation when available for specific time/date). Point of Contact: Gary Christensen, Contract Specialist, gary.christensen@va.gov. Questions regarding this notice may be submitted via e-mail to gary.christensen@va.gov.
-Pre-Solicitation11/06/2026
The Contractor shall provide FJI Diesel fuel, JIS K2204-1997-1-GO, Pour point requirement of a maximum of -2.5 C.
-Solicitation11/13/2026
E-Seal Technology from Los Alamos National Laboratory offers a transformative answer to the world’s aging wells. E-Seal is a liquid sealant that flows like water until an applied electric field steers its engineered micelles directly into the sub-millimeter cracks where cement and polymer treatments physically cannot reach, then transforms into a durable, jammed plug that holds even after the power is switched off. With an estimated tenfold cost advantage over current sealants, the ability to mitigate galvanic corrosion of well casings, and an AI-guided control system that adjusts voltage in real time as the seal forms, E-Seal stands as the first intelligent, actively steered wellbore repair platform built for the leak pathways that define modern well failure. Overview E-Seal begins as a low-viscosity, water-like fluid carrying specially engineered surfactant micelles and stabilized colloidal particles. When an electric field is applied across the target zone, three electrokinetic forces act in concert: Electrophoresis pulls the charged micelles toward the fracture, electro-osmosis drives bulk fluid flow into tight constrictions, and dielectrophoresis uses non-uniform field gradients to push larger micelle clusters into the narrowest gaps. As the micelles concentrate inside the crack, the dispersion transitions from a flowing liquid into a jammed, high-viscosity network that bridges the fracture wall-to-wall and resists pressure-driven flow even after the field is removed. Technology Description At the molecular scale, surfactant molecules in the E-Seal fluid self-assemble into micelles above the critical micelle concentration, and cement surfaces in downhole brine naturally develop an electrical double layer that interacts with these approaching charged carriers. In high-salinity brines containing divalent cations such as calcium and magnesium, the double layer compresses, inter-particle repulsion drops and micelles aggregate and adsorb onto the cement face; silica or alumina nanoparticles then reinforce the network as physical anchoring points, producing a mechanically robust plug that maintains low permeability over time. Optional additives further tune the sealant to site conditions. Trivalent cations of lanthanum and cerium raise ionic strength, accelerate micelle aggregation and can react with carbonate species in carbonate-bearing brines to precipitate low-solubility mineral phases as a secondary plugging mechanism. Crosslinked polyacrylamide derivatives, sodium polyacrylate and sulfonated polyacrylamide gel particles also can be incorporated to reinforce the seal through polymer crosslinking or by swelling on contact with the leaking fluid. Layered on top of the chemistry is an AI/ML-based real-time control pipeline that monitors sealing progress and dynamically recommends voltage adjustments as conditions evolve in the wellbore, positioning E-Seal as an actively steered rather than passively injected treatment. The applied potential difference carries a second benefit beyond transport: It helps mitigate galvanic corrosion of the well casing, addressing a long-standing integrity concern in parallel with the primary sealing function. Because the underlying transport mechanism is electrokinetic rather than pressure-driven, the same chemistry is well suited to micron-scale defects in any cementitious, porous or fractured medium, including concrete infrastructure, dams, tunnels, underground vaults, waste containment structures, clay and bentonite engineered barrier systems, repository backfill, corroded metallic interfaces, leaky caprocks, fault damage zones, abandoned mine workings and underground storage caverns. Advantages Reaches sub-millimeter microfractures and microannuli that cement squeeze jobs cannot penetrate because of particle bridging at the fracture mouth Maintains sealing performance under the high temperatures, high pressures, and aggressive brine chemistries where polymer and resin sealants typically break down Delivers an estimated tenfold cost advantage over contemporary sealing approaches Mitigates galvanic corrosion of well casings as a built-in secondary benefit of the applied electric field Uses an AI-guided control system that tracks sealing progress and adjusts voltage dynamically for a smarter, more reliable repair Applies broadly beyond wellbores to concrete, containment, and subsurface infrastructure wherever micron-scale leak paths drive failure Market Applications Oil and Gas Recovery (legacy well plugging and abandonment, sustained casing pressure remediation, methane leak compliance) Geothermal Energy (well integrity repair, asset life extension for high-cost geothermal wells) Carbon Capture (caprock and wellbore integrity for long-term CO2 containment) Critical Infrastructure (dams, tunnels, underground vaults, reservoirs) Mining and Subsurface Storage (abandoned mine workings, underground storage caverns, fault zones) S-197080 U.S. Patent pending LA-UR-26-25954 LANL Tech Partnerships: Unlock the Innovative Potential Los Alamos National Laboratory offers a wide range of cutting-edge technologies and capabilities that may provide your company with a competitive edge in the market and unlock the innovative potential that can enhance, refine, and revolutionize your products. LANL’s licensing program focuses on moving inventions developed by our researchers to commercial innovations. Patented and patent pending inventions and copyrighted software are available to existing and start-up companies through exclusive and non-exclusive licensing agreements. For specific discussions, please contact licensing@lanl.gov. Note: This is not a call for external services for the development of this technology. https://www.lanl.gov/engage/collaboration/feynman-center/partner-with-us/licensing-technology m.lanl.gov/tech-search
-Special Notice10/01/2026

Additional Details

Solicitation Number

140L1726Q0022

Archive Date

Oct 10, 2026

Office Address

Lakewood, CO, 80225